Vagina Cleaning Fractional CO2 Laser Beauty For Superfacial Acne Scar Wrinkle Removal Surgery Equipment With Medical CE And ISO Approved
USD $1 - $6,000 /Set
Min.Order:1 Set
Sunny Optoelectronic Technology Co., Ltd.
Principle of RF CO2 Fractional Laser
CO2 Fractional Laser System fires a laser beam which is split into numbers of microscopic beams, producing tiny dot or fractional treatment zones within the selected target area only. Therefore, the heat of laser only passes deeply through the fractional damaged area. This allows the skin to heal much faster than if the whole area was treated. During the skin self-resurfacing, a great amount of collagen is produced for skin rejuvenation, eventually the skin will look much healthier and younger.
Fractional CO2 Laser beauty for superfacial Acne scar surgery equipment with medical CE and ISO approved
Model:CL40F
Chinese Manufacturer in china Since 1998.
Medical CE1023,ISO13485 ,China FDA are qpproved .
1.Applications of fractional co2 laser
2 functions : For Medical Surgery use and skin rejuvenation use
Skin renewing and resurfacing;
Skin tightening;
Acne and acne scar removal;
Smooth burnt scars and surgery scars, dermabrasion etc-;
Remove intractable chloasmas and pigmentation;
Sun damage recovery.
2.Characters of fractional co2 laser:
1. China mainland glass laser tube and USA radio frequency laser tube for your choose;
2. Individual design of laser structure, greatly facility laser replacement and
easy daily maintenance;
3. Display: 8 inch color touch LCD screen
4. Humanized software control, stable laser output, more safe
5. Smart articular arm, high accuracy
6. Excellent performance, not affect people's normal life and study
7. Packing: Wooden case and Aluminum alloy case for your choose
Warranty: 1 year, technology support forever. In 1 year warranty, Our company is responsible for quality problem for free; Any non-quality problem, the buyer is in charge. Out of 1 year warranty, the buyer charge all cost for
repair and replacement.
3.Specification of our fractional laser type CL40F
Laser Technical parameters | |
Wavelengths | 10.6microns |
Control system | 8” touch screen color, |
Scan graphics | Rectangle ,Hexagon, Curve, round, triangle CO2 laser system The CO2 laser with a specific wavelength of 10.6 nm can be absorbed by human body tissue (no matter what color the skin is) by nearly 100%. Through laser emitter, the micropulsed laser beam shoots on the target skin in nanometer level to achieve a controllable precise treatment .The dimension of shooting area only can be measured in nanometer, which is precise enough for operators to control and adjust the treated depth andlayer according to the clinical diagnosis. The energy of CO2 laser is even and steady. Its focused energy aims only at target tissue without any injury to surroundings. It is the heat and electromagnetic effect of the laser that people use to conduct non-blood or less-blood cutting, cauterizing, gasification and accurate microsurgery so as to avoid skin burnt. During the treatment, biochemical reactions of optical-thermal accelerate collagen reproduction and skin recovery,after exfoliation of the tiny scar; fresh and smooth skin can be regenerated. The device outputs invisible laser. In order to operate with more ease, red semiconductor laser has been added to indicate. |
Power to tissue | 0.2--30W |
demo laser | Wavelength : 650nm brightness adjustable (10class) |
Laser delivery | 7-joint articulated arm |
Working radius | 130cm |
Pulse modes | Continuous ,Single, Repeat, Ultra Pulse |
Fractional Technical parameters | |
Treatment size | 0.1-20mm |
focus size | <0.1mm |
Pulse time | 0.1—10ms |
Dwell time Application:
1. Application Range of Fractional treatment handpiece 2. Application Range of Incision Handpiece | 0.1ms -2s |
Point spacing | 0.1--2.6mm |
Repeat | 1--20 |
Menus | 10 P |
whole machine parameters | |
Security self-check | 9 kinds of interface |
Package L*W*H | 540*540*1230mm |
Gross weight | 52kg |
Electrical | 230V/50Hz or 110V/60Hz |
Cooling system | Water closed-cycle |
Warranty | 1year |
Quality system: ISO 13485-2003 Safty standard: EN 60601-1,EN 60601-1-2, EN 60601-1-2-22, EN 60825-1 O |
4.Effects before and after
5.Features& Advantages:
1.Reduced thermal damage to surrounding tissues
2.Rapid healing and minimal downtime
3.Adjustable scanning kinds of patterns and different sizes
4.Adjustable intensity from zero to maximum
5.Adjustable pulse duration
6.Automatic alarm Systems for operation and troubles
7.High return with no consumable costs
6.About us
7.Our CE And ISO Certificates:
8.FQA
Q1: What about the delivery?
We can offer the door to door services by air or by sea, just depend on your actual request.Such as DHL, UPS, TNT, FEDEX.EMS… by air;
Q2: What’s the delivery time?
5-7 days after service.
Q3: What’s package?
Shockproof,Strong and beautiful aluminum alloy case/carton case/wooden case.
Q4: Do you have any timely technology supports?
We have a professional technology supporting team for your timely services. We prepare the technical documents for you, also you can contact us by telephone, email, online chat ( skype,wechat ,whatsapp,alibaba trade manager …).
Q5: What’s the payment method?
T/T, WESTERN UNION,Cash
Contact us
You always be welcomed to China, to our company, Sunny Laser company Shanghai China.
Main Technical Parameters:
Laser wavelength: 10.6µm
Laser unit:TEM00 module Co2 unit (best quality for the facula)
Output power: super pulse output 0.3-7W, peak value 450W,continuous output 0.3-25W
Laser output mode: continuous, single pulse, repeat pulse, super pulse, with the optional pixel laser handpiece for Pixel laser output mode
Conducting system: seven joints longer articulated arm(the most advanced conducting light system in the world and the only one in China). It could be operated in the scope of R=1.7m, which makes the operation more flexible
Handpiece:multiple function handpiece and two kinds of focus lens for f=100mm and f=50mm. With the optional adapter, it could be used for orthopedic, gynaecology and ENT surgery
Operation mode:controlled by a touch screen and with the engineer interface and the doctor interface
Min. spot diameter:≤0.1mm, variable spot adjusting handpiece:0.1-2.5mm
Pulse width: the minimum pulse width is 0.1ms