1. Technical Data
1. Eletronic Power: 220V 50HZ
2. Output Power: 200 W
3. Data display: Light Four digital Nixietube
4. Control Range: 5%-95%
5. Precision : ±0.1%
6. 4 Pre-set : 5%, 16.25%, 72.5%, 95%
2. Button Instructions:
1. “ Select” Button: When the corresponding indicator light turns off, press “↑” “↓”button to adjust PWM value “5%-95%”; while the corresponding indicator light turn on, press “↑” “↓”button to choose 4 kinds of pre-set : 5%, 16.25%, 72.5%, 95%
2. “ RED4 POWER”: The Oil ajusting speed device switch, when it light effective.
3. “ Limp home” Fixed speed switch, while the lamp light, PWM value is “95%”
4. “ Pull Down” switch, When the lamp light, PWM value is “5%”
5. “ Menu” “ Enter” Menu Operating: it can change the controller and run the programm. Before left factory, all the data have pre-set well, don’t change it by any way, and leads to abnormal usage.
3. Usage Instructions:
Connect the oil pump adjusting speed device through the cables along with test EDC itself, Open the power switch, then open “ RED4 Power”, the corresponding indicator lamp will be light, display will show “ 00.00”, it can adjust the throttle up and down through the arrow “↑” “↓”. Close the “ RED4 POWER’ switch, oil pump power off.
Press “ Select” button, indicator lamp light, and press arrow “↑” “↓” to choose pre-set rank, and press “ select” button again, indicator lamp power-off,
Then reback to the original situation.
Under the situation “ Select” light powe-off, press “ pull down” output value is “95%”, press “ Limp home”, controller output value will be “ 5%”.