induction flood light new products 2014 outdoor lighting
USD $85 - $140 /Unit
Min.Order:5 Units
Rizhao Honglang Lighting Technology Co., Ltd.
Hotselling IP65 induction flood lighting
Details:
1.Aluminum die costing housing with powder coating, which makes it solid, rustproof and durable;
2.High-temp resistant glass shade, pure aluminium reflector with professionally designed angle to maximize lighting reflection efficiency;
3.Gas-tight silicon rubber seal, with IP65;
4.Holan lamp and ballast set features with high power factors, energy saving, stable output and no glares, usually 80W-120W is applied; (optional fixtures to customers' choice)
5.Protection for ballast from short-circuit, open-circuit and defective lamp.
6.Application:Billboards, buildings, parks, pools, parking lots, plazas, tennis courts,etc.
Thank you for your choice with belief and support for RIZ Induction Lamp. To offer better professional after sales services, we will make the following commitments:
1. Warranty Period:
A) Split induction lamp series
5 Years in warranty ( for both electrical ballast and light source)
B) Integrated induction lamp series
3 Years
2. Maintenance Service:
A ) If in warranty period, the product have problems in use and maintenance. Please sent to us. We need to confirm again by QC Department. Once finishing, we will return it to you in 7 days after we receive the product.
B) If the problems can't be smoothly solved, our company will promptly change a new one to you.
C) For any product whose warranty is beyond 5 years, our company can offer free services and only charge expenses in transportation, materials and labour-hour.
1. What is induction lamp? What is the principle of induction lamp?
2. What are the methods of judging if the lamp and ballast work properly?
Indicators of detection: voltage, current, power
Problem identifying:
1) Connecting the instrument, switching on the power, if voltage can read, circuit and power can not, it means ballast has been damaged;
2) Connecting the instrument, switching on the power, if the figures displayed of power and current are more larger than the nominal ones and the tube does not light properly, it means the tube has been damaged;
3) Connecting the instrument, switching on the power, if the lamp can displayed properly, however the figure displayed of the instrument is bigger than the rated one by 50% 10 to 30 minutes later, it means the tube has been damaged.
Detection method: Preparing a complete set of lamp and ballast to do interchange detection
Problems identifying:
1) Replacing by an intract ballast, switching on the power, if the lamp does not light, it means the tube has been damaged;
2) Replacing by an intract ballast, switching on the power, if the lamp is abnormal after lighting for 30 minutes, it means the tube has been damaged;
3) Replacing by an intract ballast, switching on the power, if the lamp can not start properly, it means the tube has been damaged.