Emergency Solar power trolley
Negotiable /Set
Min.Order:1 Set
Foshan Kemapower Electronics Co., Ltd.
Key words
Pure Sine wave solar power trolley
aaLow frequency Ring transformer,stable and lower
self-consume
aaCombined solar controller and battery together
aaWith 5V USB charger, 12VDC lamp output,
12VDC 8Amp For DC big load.
aaLED Display for solar panel, battery,
DC load and inverter running Status
Digital display for AC output voltage and battery voltage
Alarm for battery low ,overload ,short circuit and so on
With AC, DC output switch and battery input switch
With Extension Bat
Technical data
Model | NST55-300LF(C) | NST55-500LF(C) | NST110-500LF(C) | NST110-1000LF(C) | NST220-500LF(C) | NST220-1000LF(C) | NST220-15001LF(C) | |
AC output | Rated power(W) | 300 | 500 | 500 | 1000 | 500 | 1000 | 1500 |
Voltage(VAC) | 110V/120V, 220V/230V | |||||||
Frequency(HZ) | 50HZ/60HZ | |||||||
Wave form | Sine wave | |||||||
AC output switch | Yes | |||||||
Battery | Battery bank voltage | 12VDC | 24VDC | 24VDC | ||||
Internal battery | 1*GEL55AH-12VDC | 2*GEL55AH-12VDC | 4*GEL55AH-12VDC | |||||
Extension battery connector | Advice 12VDC, 55AH MODE | Advice 2 pcs GEL55-12 in series | 4*GEL55AH-12VDC, 2 series 2 parallel | |||||
Recharge time | Within 3 hours | Within 3 hours | Within 6 hours | |||||
Battery switch | Yes, breaker | Yes, breaker | Yes, breaker | |||||
Grid charger(Option) | AC charge range | 110V or 220V+-25% | 110V or 220V+-25% | 110V or 220V+-27% | ||||
Charge current | 12VDC 10AMP | 24VDC 5AMP | 24VDC 5AMP | |||||
Grid change switch | Yes | Yes | Yes | |||||
Charge controller | Max current | 30A | 30A | 30A | ||||
Rated VDC | 12VDC | 24VDC | 24VDC | |||||
Input range | 10V to 25VDC | 20V to 50VDC | 20V to 50VDC | |||||
Equalizing Charge Voltage | 14.3VDC | 28.6VDC | 28.6V | |||||
Float voltage | 13.7VDC | 27.4VDC | 27.4VDC | |||||
Over charge protective voltage(VDC) | 14.2VDC | 28.4VDC | 28.4VDC | |||||
Over charge recover voltage(VDC) | 14VDC | 28VDC | 28VDC | |||||
Solar panel | Adviced capacity | 36 Cell max 500Wp | 36 Cell in series or 72 Cell max 1000Wp | 36 Cell in series or 72 Cell max 1000Wp | ||||
PV input terminal | Yes | Yes | Yes | |||||
DC output | High voltage protective voltage(VDC) | 16VDC | 32VDC | 32VDC | ||||
High voltage recover voltage(VDC) | 15.2VDC | 30.4VDC | 30.4VDC | |||||
Low voltage reover voltage(VDC) | 12.6VDC | 25.2VDC | 25.2VDC | |||||
Low voltage protective voltage(VDC) | 11VDC | 22VDC | 22VDC | |||||
Display | LED display | Solar charge status/Bad normal, over high, over low, charge protection/ DC output, ON,OFF, overload, short circuit/ Inverter overoload, short circuit, fault | ||||||
Digital display | Battery VDC, Output VAC | |||||||
Alarm | Overload bat.low, alarm/1se; battery low or high protection, alarm/3sec, inverter short circuit or fault, continous | |||||||
Fan start temperature | >45℃ | |||||||
Operation environment temperature | 0-40℃ | |||||||
Working temperature | -25- +55℃ | |||||||
Humidity | 0-90% non-condensing | |||||||
Product Size:D*W*H(mm) | 343*225*443 | 423*260*453 | 513*310*493 | |||||
Packed Size:D*W*H(mm) | 420*290*490 | 520*370*520 | 610*420*550 | |||||
G.W.of the package with bat. | 26.7 | 28.4 | 42.9 | 47.6 | 76.9 | 82.2 | 86.7 | |
Remark | Internal battery backup time | The above is around value under full load, actual using should not always full load. So should be longer, Can extension battery again | ||||||
Recharge time | The above based on max PV and use the AC/DC power charger too. Actual using is different for solar panel capacity reason | |||||||
Mode name | NST55-300LF©, N-new, ST-Solar trolley, 300W, 55-55AH/12VDC, C, with AC/DC Grid charger |
Technical specification