mini diesel medicine Incinerator
USD $5,150 - $6,130 /Set
Min.Order:1 Set
Qingdao Yimei Environment Project Co., Ltd.
LDF-30 medical solid waste incinerator
LDF series medical waste incineration installation with the characteristic of small size, high efficiency and reasonable incineration, leading technology, higher harmless degree, is the ideal garbage treatment facilities apply to all kinds of hospital, hotel, station.
Main Features:
1. The gasifying incineration technology to be applied to the incineration injector, feeding container and other medical equipment as well as different paper slash, bandage, cotton column, different kinds of medical pollutants and various wastes discharged by hospitals and medical organization.
2. The gasifying incineration way is utilized and the rubbished produced each day is able to handle the one-off incineration treatment.
3. The gasifying incineration, mixed incineration, burn-out treatment and other technologies are used to make the content of the smog exhaust and dust lower than the discharge standard regulated by the nation.
4. Fully seal operation is adopted to be applied to dealing with the infectious medical waste and avoid the secondary pollution.
5. Small volume and site area.
6. The series of incinerator are divided into the fuel and gas kind which can be selected according to the different needs of the users.
Applicable hospital size (number of beds) | 50-100 |
Burning Ability | 20-30kg/times(daily incineration 3-6 times) |
Size of the incinerator | 1600×1200×2500mm |
Volume of incinerator | Gasification chamber 0.4m3,secondary burning chamber 0.3m3,mixing burning chamber 0.03m3 |
Size of the waste filling entrance | 480x600mm |
Chimney | Height 6m,out-radius Ø300mm |
Blower | 0.37kw |
Combustion-supporting burner | Power 0.11kw,oil consumption volume 4-6kg/h |
Re-combustion burner | Power 0.11kw,oil consumption volume 6-10kg/h |
Operation voltage | 380V or 220V (can be customized according to client voltage) |
weight | About 3000kg |
Burning technical qualification | |||||
|
|
|
|
|
|
|
|
|
|
|
|
| Burner’s | Smoke’s | Burning | Destroying | Ashes’heat |
Refuse type | Temperature | Stay time | rate | rate | Decreasing rate |
Clinical refuse |
|
|
|
|
|
| ≥850° | ≥2.0 S | ≥99.9% | ≥ 99.99% | ≥95% |
Flue & Gas emission standard | |||||
Ordinal number | Refuse name | Measuring unit | GB18484-2001 |
|
|
1 | Blackness of flue gas | Ringelman class | Ⅰ |
|
|
2 | Smoke& dust | mg/m3 | 100 |
|
|
3 | CO | mg/m3 | 100 |
|
|
4 | SO2 | mg/m3 | 400 |
|
|
5 | HF | mg/m3 | 9 |
|
|
6 | NO2 | mg/m3 | 500 |
|