   HENZ3-HR Electronic Transformer Calibrator Automatic intelligent Calibration System

 

Product Description

 About this Device:

1.Digital (photovoltaic, electronic) transformer as an analog to the bridge of the world to the digital world, occupies a pivotal position in the digital substation, digital (photovoltaic, electronic) transformer that is the cornerstone of the digital substation, all digital are derived from it. Therefore, accurate precision and performance of digital (photovoltaic, electronic) transformer is very important.

 

2.Our metering law all the measuring instruments must be the amount of the pass, which means that all measuring instruments must be able to realize the magnitude of antedating.

 

3.Therefore, the practical application of digital (optoelectronic, electronic) transformer amount biography installation at the scene also need regular check, to verify the measurement accuracy and stability, as well as the standard protocol IEC61850 International Electrotechnical supported and the Statute of correctness.

 

4.HENZ3-HR electronic transformer calibrator kernel, has Dual CPU architecture, 24Bit AD chip and 512 times over-sampling techniques greatly expand the bandwidth, to improve the measurement accuracy. At the same time, the use of multi-gear automatic switching and FIR filter to improve the dynamic range and signal-to-noise ratio. Use the Labview development of management software, beautiful interface, easy to use. Power and sample input to take a large number of electromagnetic compatibility measures, to be able to adapt to the complex field test environment. With portable design, convenient laboratory and field testing.

 

5.The calibrator HENZ3-HR electronic transformer tester, is Researched and Developed in our R & D Center, produced by our company. This is a new electronic transformer calibrator calibrator using the data acquisition card + IPC structure. Using high-precision data acquisition card, data acquisition card with the new virtual instrument interface design software NI LabView, based on the WINDOWS operating system, the software interface is friendly, powerful. Apply to check and debug electronic transformer analog output and digital output can be used for electronic transformer basic accuracy of the test and the composite error test is a comprehensive function calibrator. This device has a powerful software analysis capabilities, intuitive display waveform and valid data, and data storage, offline analysis.

 

6.HENZ3-HR type electronic transformer digital output calibration system consists of: 1) a standard transformer 2) standard signal conversion apparatus, 3) standard A / D converter, 4) synchronizing signal generating means, 5) error calculating unit composition. HENZ3-HR-type electronic transformer calibrator instrument itself has 2) to 5) function, it also has analog output calibration function is a test electronic transformer digital output and analog output error Integrated Tester. Automatic intelligent tests or calibration equipment(Automatic intelligent electronic transformer test calibration system the industrial computer monitoring and control error management software and host the calibration test hardware configuration).

 

Device reference implementation of the standards and specifications:
1. JJG313-94 "Measuring the current transformer rule".
2. JJG314-94 "Measuring the voltage transformer rule".
3. JJG169-93 "transformer calibrator rule.
4. GB / T 20840-7 "transformers - Part 7: Electronic Voltage Transformer.
5. GB / T 20840-8 "Transformers Part 8: Electronic current transformer.
6. IEC61850 "substation communication networks and systems."
7. DL/T668-1999 "measuring transformer testing device.

 

Apparatus uses the operation environmental conditions:
This system unit to meet and dedicated to the voltage level of the digital (optoelectronic, electronic) transformer voltage (current) test detection and test verification tasks.
1. Altitude not exceed 1500m.
2. Ambient temperature: -15 ~ +55 ℃.
3. Air relative humidity: ≤ 90%.
4. Use Location: indoor / field use, removable.
5. Must have a reliable ground point grounding resistance <1Ω.
6. Working power: AC 220V ± 10%, about 800VA, as the actual sine wave supply 
voltage waveform.
7. Power frequency: 50/60 Hz.
8. No conductive dust, no fire and explosion hazard exists does not corrode metal and
insulation-containing gas.

 

Main Usage:
1.Meet IEC61850 the (-9-1 -9-2-9-2LE have been added) standard electronic transformers verify;

2.electronic check electronic transformer polarity and delay; small signal output transformer check;

3.parity of the merger of the small-signal input unit; 0.05 0 ~ 7V output two precision voltage signal, without l large voltage and high current can be;

rger of small signal input unit school experience (extended precision standard source module);

5.able to output a digital signal source (FT3 format), do not need to verify liter large voltage and high current can support the FT3 input merged unit. (Extended digital signal source module);

6.electronic transformer output FT3 check (Extended FT3 conversion module); to traditional transformer parity (the extended analog signal conversion module).

 

 

Main features:
1.HENZ3-HR electronic transformer calibrator for electronic transformer to meet IEC61850 (-9-1, -9-2,-9-2LE) standard output checksum. Check project include: the ratio difference, phase difference, delay, polarity.

2.At the same time small signal input terminals, electronic transformer small signal output part as well as the merger of the small-signal input unit check.

 

 

Main functions:
1. Using the traditional transformer calibrating device (BHE type) and Agilent 3458A Digital Multimeter value transfer.
2. Use the built-in GPS or high stability the crystal output pulse synchronization signal.
3. IEC61850 (-9-1, -9-2,-9-2LE) protocol packets full frame resolution automatic analysis ASDU data,Sampling points, all channel waveform diagram, no need to get caught you can visually view all channel data.
4. ST / SC dual fiber Ethernet interfaces and dual RJ45 Ethernet interface, improve reliability, and convenient access interface electronic transformer.
5. order quasi-synchronization algorithm makes non-synchronous sampling algorithm error is 
approaching zero.
6. 24Bit AD chip and 512 times oversampling technique, greatly expand the bandwidth to improve the accuracy.
7 multi-gear automatic switching and FIR filter to improve the dynamic range and reduce the signal-to-noise ratio.
8. Real-time display of the waveform, frequency, amplitude, phase, and other data to facilitate 
comprehensive analysis of transformer performance.
9. with IPC, 800 * 600 touch screen. More convenient operation.
10. with a powerful, easy operating software can be run on industrial computer or laptop
11. Statistical ratio difference and phase difference between the mean, worse, extrema, multiple error data, a comprehensive test of the stability and linearity of the electronic transformer.
12. Multiple harmonics analysis and electronic transformer harmonic accuracy check.
13. throughout the testing process. Recording and playback.
14. drop-frame test, real-time statistics of dropped frames.

 

The main technical indicators: 
1. Accuracy grade: 0.05 (worse than the error: ≤ 0.02%, a difference of error: ≤ 0.02 ° 
(ie: angle difference <2 ')). 
Built-in standards conversion devices: the accurate precision level of 0.05% level, 0.02% level, the 0.01% level.
Precision level in accordance with the standard transformer transformers and school may be chosen to match the corresponding adjustment conversion device to test parity.
Parity level: 5,3,1,0.5,0.2,0.1,0.5 S, 0.2S;
2. Communicate protocols and Statute: IEC61850-9-1/IEC61850-9-2/IEC61850-9-2LE have been add. 
3. The input range of the standard signal input range: 
1) Rated voltage: 100V and 100 / √ 3V, 100/3V.
2) Rated current input range: 1A, 5A. 
3) small signal input range 150mV, 200mV, 225mV, 4V, 1.625V , 1V, 2V, 3.25V, 4V, 6.5V. 
4) Analog Input: the signal types 100V and 1A/5A. 
The digital Input: ST type fiber optic connectors, 62.5/125 multimode fiber interface. 
4. Accuracy measurement range:
Voltage (V): 5% -120% Un (rms 0.05% RD Un = 100 / √ 3V or 100V) 
Current (A): 1% -120% In (RMS 0.05% RD In = 1A and 5A) 
Signal input: 1V above range: 1% -120% Un 0.05S level (for check metering transformer) 
Range 1V following: 100% to 2000% Un 0.05% level (for inspection protection transformer ) 
5. The harmonic test accuracy: worse than 0.1% Uh, or 0.1% Ih angle difference: 10 points 
6. AD sampling precision: better than 0.01% measure uncertainty in the magnitude of rated range. 
7. Small signal output (optional, additional charge function) 
Output voltage: 0 ~ 7V 
Output harmonic: 2 to 40 times 
The output accuracy: 0.05 to 5V 0.05% 
RD harmonic accuracy: 0.05%.
8. Input circuit power consumption
Input voltage circuit power consumption <0.2VA (100V, 57.7V)
Input current loop power consumption <1VA (5A)
Input current loop power consumption <0.2VA (1A) 
9. Ethernet interface
SC fiber interface: 1 (multitude mode fiber wavelength 820nm to 860nm)
ST fiber interface: 1 (multitude mode fiber wavelength 820nm to 860nm)
RJ45 interface 2
The optical signal has a wavelength of 820nm ~ 860nm, the optical fiber with 62.5/125 multimode glass fiber interface.
10. Synchronous
Light B code synchronization input (second pulse and B code can be configured) one
Light the code synchronization output B (second pulse and B code can configure) one
A synchronization input electric, electric synchronous output one
11. Human Interface 
Display: TFT LCD Resolution 800 * 600 
Operation: touch-screen operation, IPC USB port, you can connect a USB mouse and keyboard.
12. Whole weight ≤ 12.8kg.
13. Power supply voltage 220V ± 10%, 50/60Hz.
14. Outside air temperature (-15 ℃ ~ 55 ℃). 
15. Maximum relative humidity: <90%.
Transformer Calibrator Automatic intelligent Calibration System

Device functions and software features:
The schematic diagram of the the electronic transformer digital output check system block diagram shown in Figure 1 digital output checksum as follow:
Transformer Calibrator Automatic intelligent Calibration System

The schematic diagram of the the electronic transformer analog output check test block diagram in Figure 2 is analog output checksum.
Transformer Calibrator Automatic intelligent Calibration System

The electronic transformer digital output calibration system software development interface is shown in Figure 3, its software features and operating instructions are described as below:
Transformer Calibrator Automatic intelligent Calibration System
The electronic transformer analog output calibration system software development interface is shown in Figure 4, the software features and instructions with digital output calibration system similar set is relatively simple. Test, the analog signal is inserted through the panel on three core flight UxA connected to the transformer was measured by the school
Transformer Calibrator Automatic intelligent Calibration System

 

 

Our Services

 

(1) Specialize:

Our company engineers most from Wuhan National Grid Institute, have mature technology and wonderful products,have our first oversea order as early as 2007 year to Vietnam, have near 80 countries & areas for now, we have near 20 years experience manufacture & marketing in h.v test area, has won three national patent certification, grasp the core technology, we can customized according to your special requirement.
   

(2) Quality:
Strictly factory to user quality control, all equipments will be tested by our Quality Control Department before leave factory.The Inspection Report will be sent to you when shipment to user.
 

 (3) Service:
Timely and effective before and after sales service.
3 years warranty and technical support.
Golden supplier of alibaba, support 100% protection for product quality and first time shipment, which welcomed by our old users.

 

Packaging & Shipping

 Transformer Calibrator Automatic intelligent Calibration System

 

Company Information

 

(1) The technology support includes many national research institutions and famous universities, such as: Wuhan High-voltage Research institute, Huazhong University of science and technology, Wuhan University, China Optical Valley Industrial Base, etc. 

 

(2) It mainly carries through developing power & electric measuring calibrators, high-voltage testers, related or specialized abnormal modes in specialized fields for testing devices and searching for tech-cooperation on custom-making these products (we promise to achieve whatever you have in or out of your mind).

 

(3) We major in designing, producing and selling online monitoring systems of first and secondary equipments and their relevant softwares and tech equipments, and provide technology support too. 

 

(4) Our product market has covered nationally the domestic power system as well as other involving industries, and yearly exported quantity products aboard. We look forward to well-round technical communication and cooperation with people from different walks.

 

Transformer Calibrator Automatic intelligent Calibration System

 

Certifications

 Transformer Calibrator Automatic intelligent Calibration System

 

 

Please view more products on our website: http://hvtcn.en.china.cn/

 

 

 

 

Contact Supplier

Ms. Cici Aller Manager Chat Now
Telephone
86-27-87446394
Mobile
13163272010
Fax
86-27-87446394
Address
Wujiashan Wuhan,Hubei

You May Like

New Products

Recommended Products

View More View Less

Find Similar Products By Category

Measurement & Analysis Instruments > Electronic Measuring Instruments > Other Electronic Measuring Instruments
Categories
Hi~