S-35w-24v AC/DC single phase output LED display switching model power supply
USD $3 - $15 /Piece
Min.Order:10 Pieces
Yueqing Gechy Import And Export Co., Ltd.
S-201 220V AC TO 12v DC single output enclosed LED switching power supply
S-120 5v/12v/15v/24v/48v AC/DC single output enclosed LED switching power supply for indoor
S-400-12v/24v/36v/48v AC/DC single output type enclosed LED switching mode power supply
120W 24v LED driver constant voltage waterproof switching power supply for home
LPV-30w -12v LED driver constant voltage waterproof power switching power supply for home
S-600w-5V/12V/15V/24V/48v AC/DC single output enclosed switching power supply
S-35w-24v AC/DC single output LED display switching model power supply
China enclosed switching power supply manufacturers, builtin type chassis, metal shell, switch power supply can be used for room temperature environment. Universal ac input voltage range,have complete protection function, 100% full load aging test.Security monitoring, display, light box, suitable for indoor use.
S-35W series compact single switching power supply feature:
· Universal AC input range
· Small volume,low weight,high efficiency
· Protections: short circuit/over load
· Cooling by free air convection
· LED indicator for power on
· 100% full load burn-in test
Model | S-35-5 | S-35-12 | S-35-15 | S-35-24 | |
Output
| DC voltage | 5V | 12V | 15V | 24V |
Voltage tolerance | ±2% | ±1% | ±1% | ±1% | |
Rated current | 7A | 3A | 2.4A | 1.5A | |
Current range | 0~7A | 0~3A | 0~2.4A | 0~1.5A | |
Rated power | 25W | 36W | 36W | 36W | |
Ripple & noise | 75mvp-p | 100mvp-p | 100mvp-p | 100mvp-p | |
DC voltage adjustable range | ±10% | ±10% | ±10% | ±10% | |
Input
| Voltage range | 80~264VAC, 120~370VDC | |||
Frequency | 47~63HZ | ||||
AC current | 0.45A/230VAC | ||||
Efficiency | 76% | 78% | 78% | 80% | |
Inrush current | Cold start current 30A/230VAC | ||||
Leakage current | <1mA/240VAC | ||||
Protection
| Over load
| 105 ~ 135% rated output power | |||
Protection type: Hiccup mode, auto-recovery after fault condition is removed. | |||||
Over voltage
| 115 ~ 135% rated output power | ||||
Protection type: Hiccup mode, auto-recovery after fault condition is removed. | |||||
Environment
| Working temp,humidity | -10°C~+60°C, 20%~90%RH | |||
Storage temp,humidity | -20°C~+85°C, 10%~95%RH non-condensing | ||||
Withstand vibration | 10~500HZ,2G 10min/1cycle,period for 60 minutes,each axes | ||||
Safety
| Withstand voltage | I/P-O/P:1.5KVAC, I/P-FG:1.5KVAC, O/P-FG:0.5KVAC | |||
Isolation resistance | I/P-O/P, I/P-FG, O/P-FG: 100M ohms/500VDC | ||||
Fit standard
| Safety standard | Compliance to UL1012 | |||
EMC standard | Compliance to EN55022,CLASS A | ||||
Others
| Dimension | 84*58*38mm(L*W*H) | |||
Weight/packing | 0.15kg/80pcs/13kg/0.024m3/0.87CUFT |
Remark:
1 All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25°C of ambient temperature.
2 Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3 Tolerance: includes set up tolerance, line regulation and load regulation.
Q 1. what's the payment terms?