Two inputs AC & DC inverter with Advanced Microprocessor 2000W inverter CE FCC LVD certificates
USD $300 - $500 /Unit
Min.Order:1 Unit
Two inputs AC & DC inverter with 110VDC or 220VDC I/P 2000W inverter CE FCC LVD certificates
Two inputs AC & DC inverter with 12 / 24 / 48VDC I/P 2000W inverter CE FCC LVD certificates
Two inputs AC & DC inverter with 100 ~ 120VAC O/P 2000W inverter CE FCC LVD certificates
Two inputs AC & DC inverter with 200 ~ 240VAC O/P 2000W inverter CE FCC LVD certificates
Two inputs AC & DC inverter with PROTECTIONS 2000W inverter CE FCC LVD certificates
Two inputs AC & DC inverter with PROTECTIONS 3000W inverter CE FCC LVD certificates
n Pure Sine Wave output (THD < 3%) R Load
n Output frequency: 50/60Hz switch
n Bypass Function : AC to AC as priority and DC to AC as spare. Or, only DC to AC. Users can select it by switch.
n RS – 232C interface / remote control port / wire connection to PC
n Wired remote control
n Loading controlled cooling fan
n Advanced microprocessor
n Protection: Input Undervoltage
Input Overvoltage
Overload
Short circuit
Low battery alarm
Over temperature
Specification | Model | |||||||||
Item | YK-PST | YK-PST | YK-PST | YK-PST | YK-PST | YK-PST | YK-PST | YK-PST | YK-PST | YK-PST |
Continuous Output Power | 2000W | |||||||||
Surge Rating | 2300W (3mins) | |||||||||
Peak | 4000W | |||||||||
Input Voltage | 12V | 24V | 48V | 110V | 220V | 12V | 24V | 48V | 110V | 220V |
Frequency | 50/60Hz ± 0.05% (Switch Selectable) | |||||||||
Output Voltage Adjustment | 100~120VAC (Tune VR) | 200~240VAC (Tune VR) | ||||||||
Peak Output Current | 36A | 18A | ||||||||
Efficiency (full load) | 86% | 88% | 89% | 94% | 94% | 87% | 90% | 92% | 94% | 94% |
No load Current Draw | 1.25A | 0.56A | 0.32A | 0.38A | 0.18A | 1.79A | 0.87A | 0.40A | 0.40A | 0.20A |
Output Waveform | R Load Pure Sine Wave < 3% THD | |||||||||
P.F. | 1.0 | 1.0 | ||||||||
Input Voltage Range | 10-16 | 20-32 | 42-62 | 90-140 | 180-275 | 10-16 | 20-32 | 42-62 | 90-140 | 180-275 |
DC Input over voltage alarm | 15.5VDC | 31.0VDC | 61.0VDC | 135.0VDC | 270.0VDC | 15.5VDC | 31.0VDC | 61.0VDC | 135.0VDC | 270.0VDC |
DC Input over voltage shut-down | 16.0VDC | 32.0VDC | 62.0VDC | 140.0VDC | 275.0VDC | 16.0VDC | 32.0VDC | 62.0VDC | 140.0VDC | 275.0VDC |
DC Input under voltage alarm | 10.5VDC | 21.0VDC | 43.0VDC | 95.0VDC | 185.0VDC | 10.5VDC | 21.0VDC | 43.0VDC | 95.0VDC | 185.0VDC |
DC Input under voltage shut-down | 10.0VDC | 20.0VDC | 42.0VDC | 90.0VDC | 180.0VDC | 10.0VDC | 20.0VDC | 42.0VDC | 90.0VDC | 180.0VDC |
Protection | Overload, Short Circuit, Reverse Polarity (fuse), Input Undervoltage, Input Overvoltage, Over Temperature | |||||||||
Digital Display | OVP, UVP, OTP, OLP, VAC, AMP, WATT, VDC, TEMP, Hz | |||||||||
Safety | EN60950-1 | |||||||||
EMC | FCC Class A | EN 55022: 2006,Class A EN 55024:1998+A1:2001+A2:2003 EN 61000-3-2: 2006 EN 61000-3-3: 1995+ A1:2001+A2:2005 | ||||||||
Remote Control Unit | Optional | |||||||||
AC Input | 110VAC | 220VAC | ||||||||
AC Frequency | (50Hz ~ 60 Hz) ± 3% | (50Hz ~ 60 Hz) ± 3% | ||||||||
Bypass | 4~6ms | 4~6ms | ||||||||
Operating Temperature Range | -20℃ to 50℃ | |||||||||
Storage Temperature Range | -30℃ to 70℃ | |||||||||
Dimensions | 413(L) ×278(W) ×102(H) mm | |||||||||
Cooling | Loading controlled cooling fan | |||||||||
Weight | 7.2kgs |
1-1 Utilities Application
1-1-1 Power tools – circular saws, drills, grinders, sanders, buffers, weed and hedge trimmers, air compressors.
1-1-2 Office equipment – computers, printers, monitors, facsimile machines, scanner.
1-1-3 Household items – vacuum cleaners, fans, fluorescent and incandescent lights, shavers, sewing machines.
1-1-4 Kitchen appliances – microwave ovens, refrigerators and freezers, coffee makers, blenders, ice markers, toasters.
1-1-5 Industrial equipment – metal halide lamp, high – pressure sodium lamp.
1-1-6 Home entertainment electronics – television, VCRs, video games, stereos, musical instruments, satellite equipment.
We have 200W 350W 700W 1000W 1500W 2000W 3000W 5000W inverters for selection.
Some of our inverters have digital display on front panel to show the inverter's working state, for example : OVP (DC over voltage protection), UVP (DC under voltage protection), OTP (inverter over temperature protection), OLP (inverter over load protection), VAC, AMP, WATT, VDC, TEMP, Hz. All our inverters can be +/- 48VDC.
We have R&D team and engineers to design OEM / ODM products.
We cooperate with DHL / TNT for many years, so we can quote very good delivery charge. We cooperate with forwarder to arrange shipment around the world. We pack products in good quality carton to avoid the possible damage during transportation.