19" rack mount 2U3KVA inverter with STS
USD $1,200 - $1,700 /Piece
Min.Order:1 Piece
700W with LED indicator in front panel DC to AC PURE SINE WAVE INVERTER
good performance 700W power inverter with LED indicators and 12 24 48 VDC inputs
700W power inverter suitable for solar / wind / renewable energy system
1000W power inverter with 100~120VAC or 200~240VAC output CE LVD FCC Class B
Inverter 3000W to transfer DC power to AC power 3000W inverter
Features :
R load pure sine wave output (THD < 3%)
CE and FCC approved
With UPS combined unit
By pass function
50/60Hz switch selectable
RS – 232 interface / remote controls port / Wire connection to PC
Optional: SNMP interface
Temperature and Loading controlled cooling fan
Advanced microprocessor
Protection : Input Undervoltage, Input Overvoltage, Overload, Short circuit, Low battery alarm, Over temperature
Specification | Model | ||||||||||||
Item | YK-UIPSW | YK-UIPSW | YK-UIPSW | YK-UIPSW | YK-UIPSW | YK-UIPSW | YK-UIPSW | YK-UIPSW | YK-UIPSW | YK-UIPSW | |||
Continuous Output Power | 3000W | ||||||||||||
Surge Rating | 3Min. | 3200W | |||||||||||
3Sec. | 3500W | ||||||||||||
Peak | 6000W | ||||||||||||
Input Voltage | 12V | 24V | 48V | 110V | 220V | 12V | 24V | 48V | 110V | 220V | |||
Frequency | 50/60Hz ± 0.05% (Switch Selectable) | ||||||||||||
Output Voltage Adjustment | 100~120VAC (Tune VR) | 200~240VAC (Tune VR) | |||||||||||
Peak Output Current | 54A | 27A | |||||||||||
Efficiency | 86% | 88% | 89% | 94% | 94% | 87% | 90% | 92% | 94% | 94% | |||
No load Current Draw | 1.50A | 0.82A | 0.39A | 0.16A | 0.11A | 2.20A | 1.08A | 0.55A | 0.28A | 0.12A | |||
Output Wave form | R Load Pure Sine Wave < 3% THD | ||||||||||||
P.F. | 1.0 | 1.0 | |||||||||||
Input Voltage Range | 10-16 | 20-32 | 42-62 | 90-140 | 180-275 | 10-16 | 20-32 | 42-62 | 90-140 | 180-275 | |||
DC Input over voltage alarm | 15.5VDC | 31.0VDC | 61.0VDC | 135.0VDC | 270.0VDC | 15.5VDC | 31.0VDC | 61.0VDC | 135.0VDC | 270.0VDC | |||
DC Input over voltage shut-down | 16.0VDC | 32.0VDC | 62.0VDC | 140.0VDC | 275.0VDC | 16.0VDC | 32.0VDC | 62.0VDC | 140.0VDC | 275.0VDC | |||
DC Input under voltage alarm | 10.5VDC | 21.0VDC | 43.0VDC | 95.0VDC | 185.0VDC | 10.5VDC | 21.0VDC | 43.0VDC | 95.0VDC | 185.0VDC | |||
DC Input under voltage shut-down | 10.0VDC | 20.0VDC | 42.0VDC | 90.0VDC | 180.0VDC | 10.0VDC | 20.0VDC | 42.0VDC | 90.0VDC | 180.0VDC | |||
Protection | Overload, Short Circuit, Reverse Polarity (Fuse), Over/Under Input Voltage, Over Temperature | ||||||||||||
Digital Display | OVP, UVP, OTP, OLP, VAC, AMP, WATT, VDC, TEMP, Hz | ||||||||||||
Safety | EN60950-1 | ||||||||||||
EMC | FCC Class A | EN 55022: 2006,Class A EN 61000-3-2: 2006 EN 61000-3-3: 1995+ A1:2001+A2:2005 | |||||||||||
Interface Control Port | RS-232C With Baud Rate 2400, 4800, 9600, 19200 (Switch Selectable) | ||||||||||||
Remote Control Unit | Optional | Can’t support | Optional | Can’t support | |||||||||
AC Input | 110VAC(90~130V) | 220VAC(180~260V) | |||||||||||
AC Frequency | (50Hz ~ 60 Hz) ± 3% | (50Hz ~ 60 Hz) ± 3% | |||||||||||
Bypass | 4~6ms | 4~6ms | |||||||||||
Inverter mode or UPS mode by switch | |||||||||||||
Operating Temperature Range | -20°C to 50°C
| ||||||||||||
Storage Temperature Range | -30°C to 70°C
| ||||||||||||
Dimensions | 445(L) ×424(W) ×88(H) mm | ||||||||||||
Weight | 14.3kgs |