electro magnetic flow meter with RS232 communication
USD $399 - $3,999 /Piece
Min.Order:1 Piece
Kaifeng Kaide Flow Instrument Co., Ltd.
electro magnetic flow meter with RS232 communication
Product Pictures of eletromagnetic flowmeter
Product Description of eletromagnetic flowmeter
Electromagnetic flow meter is a kind of induction type flow instrument often used to measure, based on Faraday Law, the volume flowrate of conductive medium in closed pipelines. With microprocessor and exclusive integrated circuit, KDLD electromagnetic flow meter have the advantages of reliable performance, high accuracy, easy to use, etc.. The high speed CPU and advanced signal processing technology ensure a wide measuring range of 0.01m/s to 12m/s. The infrared remote control realize man-machine conversation, two-line LCD makes the readings and parameter setting more comprehensive and convenient.
The Kaide Meter KDLD Series electromagnetic flow meter is intended for fluid metering in most industries including water, wastewater, food and beverage, pharmaceutical and chemical.
The basic components of an electromagnetic flow meter are:
The sensor/ detector, which includes the flow tube, isolating liner and measuring electrodes
The converter/ transmitter, which is the electronic device responsible for the signal processing, flow calculation, display and output signals.
Each meter is factory tested and calibrated A calibration certificate is included with each meter.
Peak flow rate | 15m/s | ||||
Accuracy (refer to accuracy curve) | Indication ±0.5%(flow rate no less than 0.8m/s) | ||||
Conductibility of fluid | Above 5μ S/cm | ||||
Nominal pressure | DN15~ DN150 | 4.0Mpa | |||
DN15~DN600 | 1.6Mpa | ||||
DN200~DN1000 | 1.0Mpa | ||||
DN200~DN3000 | 0.6Mpa | ||||
Ambient temperature | Sensor | -25~+60 Deg C | |||
Compact flow meter and converter | -10~+60 Deg C | ||||
The liner material and maximum temperature of fluid | Liner material | Remote type | Compact type | ||
Polytetrafluoroethylene (PTFE) | 100°C(standard) 150°C(special order) | 70°C | |||
Polyvinyl fluoride (PVF) | 100°C(standard) 150°C(special order) | 70°C | |||
Fluorinated ethylene-propylene(FEP) | 100°C(standard) 150°C(special order) | 70°C | |||
Polychloropree rubber(CR) | 80°C(standard) 120°C(special order) | 70°C | |||
Polyurethane(PU) | 80°C | 70°C | |||
Electrode type | Fixed type(DN150~DN2600); Blade type(DN300~DN1600) | ||||
Material of signal electrode and grounding electrode | Mo-containing stainless steel, hastelloy B, hastelloy C, tantalum alloy, titanium alloy, platinum-iridium alloy, stainless steel-coated wolfram carbide | ||||
Flange material | Carbon steel | ||||
Grounding flange material | Stainless steel 1Cr18Ni9Ti | ||||
Seal ring material | PTFE | ||||
Material of inlet protection flange | DN6~DN600 | Stainless steel 1Cr18Ni9Ti | |||
DN700~DN3000 | Carbon steel | ||||
Shell protection | DN6~DN150 remote sensor with rubber or polyurethane liner | IP65(standard), IP68(special order) | |||
DN200~DN3000 remote sensor with rubber or polyurethane liner | IP68(able to 5~10m under water usage) | ||||
Other sensor and all kinds of converter | IP65 | ||||
Power supply | 24VDC/220VAC | ||||
Signal output | Pulse, 4-20mA | ||||
Communication | RS485, Modbus(standard), RS232,HART,Profibus, GPRS(special order) | ||||
Display | Digital 2-line LCD, able to display positive and negative instantaneous flow and accumulative flow | ||||
Spacing (remote type) | Generally, the spacing between converter and sensor is no longer than 100 meters, special order will be required when it is longer than 100 meters. |
Production steps of electromagnetic flow meter
Characteristics of electromagnetic flow meter
1. Variable forms for different kinds of working conditions. Compact and remote form; Flanged,
flange wafer, clamped, threaded, insertion end connection; DC/AC, battery power supply.
2. High accuracy of ±0.5%.
3. Wide size range of 10mm~3000mm, adapt to different size of pipelines.
4. Full choice of liner to accommodate conductive medium from drinking water to strongly corrosive liquid like sulfuric acid.
5. Measurement is not affected by the density, viscosity, temperature, pressure and electroconductibility of fluid.
6. Two-line LCD, able to display positive and negative instantaneous flow and accumulative flow.
7. No pressure loss. No moving parts.
8. Pulse and 4~20mA standard current output. Multiple choice of communications: RS232, RS485, Modbus, Profibus, HART, etc..
9. Surface mount technology(SMT) technology of converter which possesses self-check and self-diagnose functions.
10. Explosion-proof type can be used at relevant explosion-proof sites. IP68 remote type can be used underwater.
More Products for You to Choose
Company information
Why Choose Us
We have been in this business for more than ten years.
Our customer satisfaction is 99. 5%.
We are located in Kaifeng, the most ancient and biggest base of flow instrument in China, which means we have full access to the most advanced technologies in this field.
We are awarded ISO9001:2008.
Our belief is "Accuracy and Attitude, Access to Customer".
Our monthly output of electromagnetic flow meters is 3000 sets.
We are able to provide electromagnetic flow meters with international standards.
Our goal is to make world wide brand.
Packaging & Shipping
1.Packing:export plywood case packaging,including instructions and certificates
2.Delivery Time:Within1-20 sets electromangetic flow meters,2-7 wording days after payment
3.Shipment:Express(FedEx,DHL,UPS&TNT),by air/ocean or other methods available
Certifications
Contact
Let's enjoy your shopping in KAIDE FLOW INSTRUMENT!