SANPU 2013 hot selling CE ROHS FX 100W 27V co2 laser power supply led power led driver led strip transformer
USD $1 - $16 /Piece
Min.Order:1 Piece
Shenzhen Sanpu Intelligent Technology Co., Ltd.
SANPU 2013 hot selling CE ROHS FX 100W 27V co2 laser power supply led power led driver led strip transformer
Feathers:
1. Universal AC input / Full range;
2. 100% full load burn-in test;
3. Built-in EMI fiter with tiny ripple;
4. High efficiency, high qulity, long life and high reliability;
5. Abnormality protection function : short circuit ,over load ,over voltage,over temp;
6. Convenient wiring;
7. The product consists of indoor type and outdoor type;
8. Various types for your choice:Constant Voltage Power supply and Constant Current Power supply.
FX Waterproof FX100-W1V | |||||||
MODEL | 5V 100W | 12V 100W | 15V 100W | 24V 100W | 27V 100W | 48V 100W | |
OUTPUT | DC VOLTAGE | 5V | 12V | 15V | 24V | 27V | 48V |
RATED CURRENT | 20A | 8.5A | 6.7A | 4.5A | 3.7A | 2.0A | |
CURRENT RANGE | 0~20A | 0~8.5A | 0~6.7A | 0~4.5A | 0~3.7A | 0~2.0A | |
RATED POWER | 100W | 100W | 100W | 100W | 100W | 100W | |
RIPPLE& NOISE (MAX.)NOTE2 | 100mV | 120mV | 120mV | 120mV | 120mV | 200mV | |
VOLTAGE TOLERANCENOTE3 | ±2% | ±1% | ±1% | ±1% | ±1% | ±1% | |
SETUP , RISE TIME | 200ms/220VAC 50ms/220VAC | ||||||
HOLD UP TIME(Typ.) | 20ms/220VAC | ||||||
INPUT | VOLTAGE RANGE | 85~132VAC/170~264VAC | |||||
FREQUENCY RANGE | 47~63Hz | ||||||
POWER FACTOR(Typ.) | PF>0.6/220VAC | ||||||
EFFICIENCY(Typ.) | 81% | 84% | 85% | 85% | 86% | 86% | |
AC CURRENT(Typ.) | 2.4A/115VAC 1.2A/230VAC | ||||||
INRUSH CURRENT(Typ.) | COLD START 20A/115VAC 40A/230VAC | ||||||
PROTECTION | Short circuit | Protection type : recovers automatically after fault condition is removed | |||||
Over load | 105~135% hiccup mode , auto-recovery | ||||||
ENVIRONMENT | WORKING TEMP | -20°C~ +60°C | |||||
WORKING HUMIDITY | 20%~90%RH | ||||||
STORAGE TEMP , HUMIDITY | -40°C~+85°C,10%~90%RH | ||||||
SAFETY &EMC | SAFETY STANDARDS | CE,ROHS | |||||
WITHSTAND VOLTAGE | I/P-O/P:1.5KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC | ||||||
EMC Test Standards | Conform to EN60950 GB4943 UL60950 Safety standards | ||||||
Conform to GB9254 EN55022 EMC standards | |||||||
NOTE | 1.All paraments NOT specially mentioned are measured at 220VAC input ,reted load and 25°C of ambient temperature 2.Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1 uf & 10 uf parallel capacitpr . 3.Tolerance : includes set up tolerance , line regulation and load regulation . | ||||||