ETCR2000C+ Clamp On Ground Earth Resistance Tester Meter----ISO,CE,OEM,RS232 interface
ETCR2000C+ Clamp On Ground Earth Resistance Tester Meter----ISO,CE,OEM,RS232 interface
ETCR2000C+ Clamp On Ground Earth Resistance Tester Meter----ISO,CE,OEM,RS232 interface
ETCR2000C+ Clamp On Ground Earth Resistance Tester Meter----ISO,CE,OEM,RS232 interface
ETCR2000C+ Clamp On Ground Earth Resistance Tester Meter----ISO,CE,OEM,RS232 interface
ETCR2000C+ Clamp On Ground Earth Resistance Tester Meter----ISO,CE,OEM,RS232 interface

ETCR2000C+ Clamp On Ground Earth Resistance Tester Meter----ISO,CE,OEM,RS232 interface

USD $301.59 - $430.16 /Piece

Min.Order:1 Piece

Supply Ability:
1000 Piece / Pieces per Month
Port:
Guangzhou
Payment Terms:
T/T Credit Card PayPal

Quick Details View All >

Place of Origin:
Guangdong, China
Brand Name:
ETCR
Model Number:
ETCR2000C+
Display Type:
Digital Only
Measuring Range:
0.01-1200ohm,0.0mA-20A
Accuracy Class:
0.001ohm,0.05mA

Guangzhou ETCR Electronic Technology Co., Ltd.

Business Type: Manufacturer
Guangzhou Guangdong China
Main Products: Phase Detector ,Damp Resistance Tester ,Current Meter ,Current Sensor ,Soft Magnetic Alloy Core

Product Details

Specifications

Clamp On Ground Earth Resistance Tester Meter
1.Range:0.01-1200ohm,0.0mA-20A
2.Resolution:0.001ohm,0.05mA
3.Stored:99,RS232

             ETCR2000C+ Clamp On Ground Earth Resistance Tester Meter

 

Our buyers have stayed with us for 12 years

12 years of specialized meters

ISO Patent and CE certificate 

OEM services available

More information, please kindly view our web site:  /en/

Online store:     /store/502192

 

. Product Characteristics

Clamp size: 65×32 (mm), Resistance Range: 0.01~1200(Ω), Resistance resolution: 0.001Ω, Current Range: 0.00mA-20.0A, Current resolution: 0.05mA, Data memory: 99 sets, Alarm setting: 1~199(Ω), Buzzer alarm. Optional function of RS232 interface data upload.

  

. Introduction

ETCR Clamp Earth Resistance Tester is widely applied in ground resistance measurement, loop resistance measurement in fields such as electric power, telecommunications, meteorology, oil field, architecture and industrial electrical equipment, etc. When measuring ground system with loop, there is no need to disconnect the ground wire without auxiliary electrode, which means safer and faster. ETCR Clamp Earth Resistance Tester can measure the ground fault which can not be measured by traditional method, can apply in the occasion where traditional methods are unworkable; ETCR Clamp Earth Resistance Tester measures the integrated value of ground resistance and resistance lead. What’s more, ETCR 2000C+ Series tester can measure the leakage current of ground wire.

ETCR new Clamp Earth Resistance Tester is another perfect upgrade on old models. The performance contrast of new and old products shows below:

Items

ETCR2000(Old Type)

ETCR2000+(New Type)

Product Appearance
 
 

ETCR2000C+ Clamp On Ground Earth Resistance Tester Meter----ISO,CE,OEM,RS232 interface

 

ETCR2000C+ Clamp On Ground Earth Resistance Tester Meter----ISO,CE,OEM,RS232 interface

Boot TimeSelf-test needs 6 seconds, long boot time may easily result in boot error.Self-test in 0.5 second, boot instantly
Measuring Range0.01-1000Ω0.01-1200Ω, Wider range
Stored Data30 sets99 sets
Beep AlarmingNoYes
Interference IdentificationNoWith beeps and NOISE symbol blinking. Strong anti-interference ability.
RS232 InterfaceNoRS232 interface Available
Power Consumption100mA, Maximum 100mAMaximum 50mA, Longer battery life
Meter AppearanceHeavy machine, Rough appearance, Hard operationFine appearance, More fixed structure, Easy operation
BatteryCoverNo screws, Easy to result in accident hidden trouble due to battery off.With fastening screws, Secure, Reliable, Easy battery replacement.

 

. Technical Specifications  

Range0.01-1200Ω;   0.0mA-20A
Resolution0.001Ω;       0.05mA
Sound and light alarm"beep - beep - beep -" alarm sound, Flashing alarm symbol, By AL key to open, close, set
LCD4-digital LCD, 47×28.5mm in length
Working temperature-20-55
Relative Humidity10-90
Explosion-proof markExia BT3
ShiftAutomatic Shifting
External Magnetic Field40A/m
External Electric Field1V/m
Single Measurement Time0.5 second
Resistance Measurement Frequency1KHz
The Measured Current Frequency50/60Hz Automatism
Storable Measurement Data99groups
SettingRangeof Resistance Alarm Critical Value1-199 Ω
SettingRangeof Current Alarm Critical Value1-499mA
Protection LevelDouble insulation
Structural FeatureIn the jaw way CT
Power Source6VDC (4 ×5# alkaline battery)
Span of Jaw28mm
Net Weight (including batteries)1160g
Dimension285mmlong, 85mm wide,56mm thick
AccessoriesMeter1 PCS Test Ring1 PCS Meter Box1 PCS

 

. Field Application 

 

ETCR2000C+ Clamp On Ground Earth Resistance Tester Meter----ISO,CE,OEM,RS232 interface

 ETCR2000C+ Clamp On Ground Earth Resistance Tester Meter----ISO,CE,OEM,RS232 interface

ETCR2000C+ Clamp On Ground Earth Resistance Tester Meter----ISO,CE,OEM,RS232 interface

 

 

 

 

Contact Supplier

Ms. Lili Su Sales Manager Chat Now
Telephone
86-020-62199556
Mobile
13802922567
Fax
86-020-62199550
Address
F-3F,No.4 Pengshang Zhifu Road, Jiahe,Baiyun District,Guangzhou,Guangdong,China. Guangzhou,Guangdong

You May Like

New Products

Recommended Products

View More View Less

Find Similar Products By Category

Measurement & Analysis Instruments > Electrical Instruments > Resistance Meters
Categories
Hi~