500 measuring data coating Thickness Gauge TG-8831FN
USD $240 - $300 /Set
Min.Order:1 Set
data logger ultrasonic thickness gauge through coating thickness gauge TG-5000DL
echo-echo funciton through coating ultrasonic thickness Gauge TG4000
distinct ultrasonic Thickness Gauge TG8812 with RS232/bluetooth
1 point calibration /2 point calibration /basic calibration Coating Thickness Gauge TG8832FN
TG-7521 magnetic induction (F) principle portable coating thickness gauge,coating inspection
TG8831FN digital coating thickness gauge is using the magnetism and backset measuring thickness method .It can measure the thickness of the magnetism metal substrate (such as steel, iron, alloy and rigid magnetism steel and etc), non-magnetism cover layer (such as aluminum, chrome, copper, enamel, rubber, oil paint and etc) and non-magnetism metal substrate (such as copper, aluminum, zinc, tin and etc) and non-transmitting electricity cover layer (such as enamel, rubber, oil paint, plastic and etc). This instrument has small error of measure, excellent performance and good stability, easy operation and other characteristics, is a necessary measure instrument to control and guarantee the product quality, can be widely applied to manufacturing, metal processing industry, chemical industry, merchandise test fields.
Features
l Precise measurements (2%+1)/(1%+1)
l Quick measuring response and rapid measuring speed
l Design of two independent parts ,better applicability, stable measurement results
l Strong data processing and analysis :5 types of Statistic value and histogram
Technical Specification
Measuring range | F400:0~400μm,N400:0~400μm,F1:0~1250μm,F1/90:0~1250μm, N1:0~1250μm,F10:0~10000μm,CN02:10~200μm, | |
Measuring accuracy | 1 point calibration : ±(2%+1)2 point calibration : ±(1%+1) | |
Calibration | 1 point calibration /2 point calibration /basic calibration | |
Display resolution | 0.1um (0~99.9um) / 1um (Over 100um) | |
Weight | 250g(including battery package ) | |
Operation environment | Temperature: 0°C~50°C humidity: 20%RH~90%RH | |
Operation mode | Direct testing mode and block statistics mode | |
Measuring mode | continuous/single | |
Shutdown mode | manual/automatic | |
Operation alarm | Ring music to alarm mistake | |
Signal Dealing | ||
Threshold | Limits setting and automatically alarm measured values out of limit | |
Data analysis | Analyzing a batch of measuring values via histogram | |
Statistic function | Mean/ Standard deviation / Number of measurements/ Maximum/ Minimum | |
Data Merory | ||
Thickness values | 500 measuring data | |
Delete | Single doubtful data / All data of one group | |
Power supply | ||
Battery | 9V Nickel-hydride/ alkaline batteries | |
Power battery inspection | low voltage indication | |
Standard delivery | Main unit | 1 |
Integrated probe((N 1 or F1 ) | 1 | |
Calibration foil set | 4 | |
Calibration base set | 1 | |
9V alkaline battery | 1 | |
Instruction manual | 1 | |
Optional accessories | ||
probe | F400,N400,F1/90,F10,CN02 |