Stainless steel/cast steel type of impact device, portable leeb rebound hardness tester accessories
Negotiable /Set
Min.Order:1 Set
Stainless steel / cast steel Portable Hardness tester accessory device support HL, HB, HS
Material | Method | Impact device | |||||
D/DC | D+15 | C | G | E | DL | ||
Steel and cast steel
| HRC | 20~68.5 | 19.3~67.9 | 20.0~69.5 |
| 22.4~70.7 | 20.6~68.2 |
HRB | 38.4~99.6 |
|
| 47.7~99.9 |
| 37.0~99.9 | |
HRA | 59.1~85.8 |
|
|
| 61.7~88.0 |
| |
HB | 127~651 | 80~638 | 80~683 | 90~646 | 83~663 | 81~646 | |
HV | 83~976 | 80~937 | 80~996 |
| 84~1042 | 80~950 | |
HS | 32.2~99.5 | 33.3~99.3 | 31.8~102.1 |
| 35.8~102.6 | 30.6~96.8 | |
Cold work tool steel | HRC | 20.4~67.1 | 19.8~68.2 | 20.7~68.2 |
| 22.6~70.2 |
|
HV | 80~898 | 80~935 | 100~941 |
| 82~1009 |
| |
Stainless steel
| HRB | 46.5~101.7 |
|
|
|
|
|
HB | 85~655 |
|
|
|
|
| |
HV | 85~802 |
|
|
|
|
| |
Grey cast iron
| HRC |
|
|
|
|
|
|
HB | 93~334 |
|
| 92~326 |
|
| |
HV |
|
|
|
|
|
| |
Nodular cast iron | HRC |
|
|
|
|
|
|
HB | 131~387 |
|
| 127~364 |
|
| |
HV |
|
|
|
|
|
| |
Cast aluminium alloys | HB | 19~164 |
| 23~210 | 32~168 |
|
|
HRB | 23.8~84.6 |
| 22.7~85.0 | 23.8~85.5 |
|
| |
BRASS(copper-zinc alloys)
| HB | 40~173 |
|
|
|
|
|
HRB | 13.5~95.3 |
|
|
|
|
| |
BRONZE(copper-aluminium/tin alloys) | HB | 60~290 |
|
|
|
|
|
Wrought copper alloys | HB | 45~315 |
|
|
|
|
|
Available type of impact device |
| DC: Test hole or hollow cylindrical
| D+15: Test groove or reentrant surface
| C:Test small, light, thin parts and surface of hardened layer |
G: Test large, thick, heavy and rough surface steel | E: Test super high hardness material | DL: Test slender narrow groove or hole |
Type of impact device | DC(D)/DL | D+15 | C | G | E |
Impacting energy Mass of impact body | 11mJ 5.5g/7.2g | 11mJ 7.8g | 2.7mJ 3.0g | 90mJ 20.0g | 11mJ 5.5g |
Test tip hardness: Dia. Test tip: Material of test tip: | 1600HV 3mm Tungsten carbide | 1600HV 3mm Tungsten carbide | 1600HV 3mm Tungsten carbide | 1600HV 5mm Tungsten carbide | 5000HV 3mm synthetic diamond |
Impact device diameter: Impact device length: Impact device weight: | 20mm 86(147)/ 75mm 50g | 20mm 162mm 80g | 20mm 141mm 75g | 30mm 254mm 250g | 20mm 155mm 80g |
Max. hardness of sample | 940HV | 940HV | 1000HV | 650HB | 1200HV |
Mean roughness value of sample surface Ra: | 1.6μm | 1.6μm | 0.4μm | 6.3μm | 1.6μm |
Min. weight of sample: Measure directly Need support firmly Need coupling tightly |
>5kg 2~5kg 0.05~2kg |
>5kg 2~5kg 0.05~2kg |
>1.5kg 0.5~1.5kg 0.02~0.5kg |
>15kg 5~15kg 0.5~5kg |
>5kg 2~5kg 0.05~2kg |
Min. thickness of sample Coupling tightly Min. layer thickness for surface hardening |
5mm
≥0.8mm |
5mm
≥0.8mm |
1mm
≥0.2mm |
10mm
≥1.2mm |
5mm
≥0.8mm |
Size of tip indentation
| ||||||
Hardness 300HV | Indentation diameter Depth of indentation | 0.54mm
24μm | 0.54mm
24μm | 0.38mm
12μm | 1.03mm
53μm | 0.54mm
24μm |
Hardness 600HV | Indentation diameter Depth of indentation | 0.54mm
17μm | 0.54mm
17μm | 0.32mm
8μm | 0.90mm
41μm | 0.54mm
17μm |
Hardness 800HV | Indentation diameter Depth of indentation | 0.35mm
10μm | 0.35mm
10μm | 0.35mm
7μm | --
-- | 0.35mm
10μm |