Steel-bar Location Tester HLT200
Negotiable /Set
Min.Order:1 Set
HTH-225 Non-Digital Type-In-One Concrete Schmidt Test Hammer/Used Concrete Testing Equipments
New type Digital Concrete Test Hammer, Integrated Voice Digital Test Hammer
Non-digital Type-in-one concrete test hammer (schmidt hammer)
HTH-225 Non-digital Type-in-one concrete test hammer (schmidt hammer)
HTH-225V Type-in-one Voice,Digital Test Hammer, schmidt concrete test hammer
Steel-bar Location Tester HLT200
Purpose
HLT200 steel-bar Location tester used to test
steel-bar diameter, Distribution, backing thickness
in concrete.
Specification
<Technical specification for test of reinforcing
Steel bar in concrete> JGJ/T152-2008
Performance
1.Longer service life of the connector clip.The instrument has long service life because of using lemo connector clip which comes form Switzerland and use for aircraft industry.
2.Good quality of signal cable. The signal cable has long service life because of its flexible and substance .
3.High precision and stability. The instrument can locate the steel-bar accurately and quickly.
4. Longer service life of the sensor. Improve the service life by paste abrasion resistance allowance on the bottom of the sensor.
5.Single sensor. No-change sensor in test. itcan assure the precision of test data and the test depth that switching between high and low test range.
6. Display test information real-time.Interpret and display the test data Intelligently to avoid man-made errors.
7.Powerful data process and analysis software in windows. Test data can be export to word or Excel easily.
Technical Data
Applicable steel-bar diameter | Dia 6 mm~Dia 50 mm | ||
Tested range of concrete backing thickness | Low range:6 mm~90 mm;High range:7 mm~190 mm | ||
permissible error |
| Low range | High range |
±1 | 6~59 | 7~79 | |
±2 | 60~69 | 80~119 | |
±4 | 70~90 | 120~190 | |
Tested range of steel-bar diameter | dia 6 mm~dia 50 mm | ||
Permissible error of steel-bar diameter test | ±1 grade | ||
Applicable environmental | temperature:-10°C~+40°C;Dampness:<90%RH EMI: no Strong electromagnetic field | ||
Power supply | 6 dry cells,work more than 30 times | ||
Power supply | 6 dry cells,work more than 30 times |