Water Cooled Chiller
For Air Conditioning Cooling
LTLS Series 100-2000KW
Screw Compressors
CE, CRAA Certificate

Water Cooled Chiller for Air Conditioning Cooling (LTLS Series 100-2000KW)

 

Model Details:

LT     L   S---30   W(R)     S(D)

LT--LVTE Company Products Code  

L--Screw Compressors    

S--Chiller, Cooling Only

30--Compressor HP  

W--Water Cooled  

R--With Heat Recovery    

S(D)—Single(Double) Compressor

 

LTLS-W(R)S(D) Series Water Cooled Chiller

-Semi-hermetic Screw Compressors Units;

-Most used for Central Air Conditioning Cooling System;

-Condenser Chiller Water Inlet/Outlet Temperature: 12°C/7°C; Evaporator Cooling Water Inlet/Outlet Temperature: 30°C/35°C;

-Heat Recovery is an optional.

 

-Single Compressor Unit Model: LTLS-30W(R)S to LTLS-200W(R)S(Capacity 100KW-823.6KW/30Tons-250Tons)

Water Cooled Chiller for Air Conditioning Cooling (LTLS Series 100-2000KW)

Remark:1.Colling Condition: Chilled water in/out 12/7°C; Cooling water in/out 30/35°C;

2.Power supply: 3P-380V-50HZ;with voltage allowance ±10%,voltage dif between the phase lines±2%;

3.The data above is for R22, contact us if that for R134a,R407c and other refrigerant need;

4.There may be Changes for improvement without notice, confirm always before your order.

 

 

Water Cooled Chiller for Air Conditioning Cooling (LTLS Series 100-2000KW)

Remark:1.Colling Condition: Chilled water in/out 12/7°C; Cooling water in/out 30/35°C;

2.Power supply: 3P-380V-50HZ;with voltage allowance ±10%,voltage dif between the phase lines±2%;

3.The data above is for R22, contact us if that for R134a,R407c and other refrigerant need;

4.There may be Changes for improvement without notice, confirm always before your order.

 

 

-Double Compressors Unit Model: LTLS-60W(R)D to LTLS-400W(R)D(Capacity 200KW-2000KW/60Tons-500Tons)

 Water Cooled Chiller for Air Conditioning Cooling (LTLS Series 100-2000KW)

Remark:1.Colling Condition: Chilled water in/out 12/7°C; Cooling water in/out 30/35°C;

 2.Power supply: 3P-380V-50HZ;with voltage allowance ±10%,voltage dif between the phase lines±2%;

3.The data above is for R22, contact us if that for R134a,R407c and other refrigerant need;

4.There may be Changes for improvement without notice, confirm always before your order.

 

Water Cooled Chiller for Air Conditioning Cooling (LTLS Series 100-2000KW)

Remark:1.Colling Condition: Chilled water in/out 12/7°C; Cooling water in/out 30/35°C;

 2.Power supply: 3P-380V-50HZ;with voltage allowance ±10%,voltage dif between the phase lines±2%;

3.The data above is for R22, contact us if that for R134a,R407c and other refrigerant need;

4.There may be Changes for improvement without notice, confirm always before your order.

 

Features:

1.Wide application as hotel, apartment, villa, factory, shopping center, office building, school, etc.

2. Semi-hermetic screw compressor for all models. Each compressor is equipped with a crankcase heater and a thermal overload cut-out, the screw compressor is also complete with a built-in electronic protection with temperature sensor located directly in the motor winding and on the discharge line.

3. The refrigerant circuit is complete with sight glass, filter drier, high and low pressure gauges, solenoid valve, direct expansion valve, high and low pressure switch.

4. The unit is of high performance as they are made of the condensers and evaporators of grooved copper pipes, and high quality components, by specialized process.

5. The electric panel consists of compressor breaker, compressor contactor, phase sequence relay, control circuit breaker, microprocessor control with function display.

6. LCD display, touch screen control panel as standard.

7. Automatic operation dramatically reducing maintenance cost thanks to reliable microprocessor system.

8. For the units with semi-hermetic screw compressor, an infinitely variable capacity control system that is capable of exactly matching the demand requirement of the system is to be supplied. This system is to provide precise and stable control of supply water temperature over the complete range of operating conditions.

OPTIONAL

Electronic expansion valve

Desuperheater as optional.

Electronic controller with BMS system.

Low noise compressor cabinet or outside full cover

Channel Steel base

 

System Control

1. Imaged system operation chart, showing the temperature of water in/out, the energy level of compressor run, on/off button, run time, alarm etc. And the remote turn on/off function is available. PC remote control is optional.

2. Notice for maintenance is indicated according to the accumulated run time of the compressor.It is convenience to maintenance.

3. The control system will automatically balance the run time for each compressor for mult-compressor unit.

 

Safety Protections

1. Discharge check value:it prevents the discharged gas from going back after the compressor stops.

2. Phase lack protection:It protects the compressor for over high voltage, voltage dificiency, and phase lack.

3. Direction protection:It protects the compressor from damage resulted from Counter direction run.

4. Oil heater: It heats the oil before the unit start, keep the good lubrication for the unit before it runs.

5. Overheat protection inside the motor of the compressor: It protects the compressor from burning down for too high coil temperature for overload, or abnormal run condition.

6. High&low pressure protection:It protects the compressor and system against extreme run condition and trouble.

7. Freezing protection:It protects the unit form too low temperature of the water out, freezing may occerat some place,resulting in freezing breaking of the evaporator.

8. Water flow protect: It protects the unit from run without water flow.

9. High temperature of chilled water protection: It works to protect the compressor in case that the load is too large, the temperature of chilled water is too high. It may result in compressor failure without this protect in the case.

 

Bitzer Double Compressors Water Cooled Chiller:

Water Cooled Chiller for Air Conditioning Cooling (LTLS Series 100-2000KW)Water Cooled Chiller for Air Conditioning Cooling (LTLS Series 100-2000KW)Water Cooled Chiller for Air Conditioning Cooling (LTLS Series 100-2000KW)Water Cooled Chiller for Air Conditioning Cooling (LTLS Series 100-2000KW)

 

Chiller Export: Loading the Container

Water Cooled Chiller for Air Conditioning Cooling (LTLS Series 100-2000KW)

 

 

 

 

Contact Supplier

Mr. Jack Jin Marketing Director Chat Now
Telephone
86-536-2119006
Mobile
0086 15094977989
Fax
86-536-2257000
Address
No. 3999, South Airport Road, Weicheng District Weifang,Shandong

You May Like

New Products

Recommended Products

View More View Less

Find Similar Products By Category

Construction & Real Estate > HVAC Systems & Parts
Categories
Hi~