LTWF Hermetic Scroll Type Compressor Air Source Heat Pump and Chiller,Box Air Cooled Water Chiller
USD $2,500 - $35,600 /Set
Min.Order:1 Set
Shandong Lvte Air Conditioning System Co., Ltd.
LTWF Hermetic 3-Phase Scroll Type Compressor Air Source Heat Pump and Chiller,Box Type Air Cooled Water Chiller
Model Specifications: LTWF-68 A S E(P)
LT-LVTE Company Products Code
W-Scroll Type Compressor
F-Air Cooled Type Chiller
E-Built in Water Pump and Water Vessel; P-Built in Water Pump without Vessel; Empty-No Pump and Vessel
Air Cooled Chiller Features:
1.With scroll, or reciprocating compressor of high quality, high efficient heat exchangers, excellent system design, by excellent process, the chillers is of suffient capacity and efficiency.
2.The chillers will work stably for long time period as they are produced by excllent process, composed of reliable control components and professional control procedure.
3. Units with V type heat exchanger: panels, frame and base are made from galvanized steel protected with polyester powder painting to ensure total resistance to atmospheric agents.
4. 3-phase scroll type compressor, with built-in thermal overload cut-out and crankcase heater, mounted on rubber vibration dampers.
5. External rotor type axial fans, equipped with three phase direct drive motors, low noise 8 poles, protection level IP54, provided with a protective outlet grille.
6. Evaporator built with high efficiency tube in tube type heat exchanger, factory insulated with flexible close cell material.
7.Condenser built with seamless copper tubes mechanically expanded into blue hydrophilic aluminum fins.
8. Refrigerant circuit complete with charge valves, filter drier, sight glass, gas-liquid separator, thermostatic expansion valve high & low pressure switch.
9. Hydraulic circuit built with galvanized pipe, complete with water discharge connection for tube in tube heat exchanger and flange type hydraulic connectors in two directions easy for connections from both sides of the units.
10. Electric panel consist of: compressor contactor, fan motor contactor, compressor protection breaker, fan protection breaker, phase sequence relay and microprocessor with function display (display only for master/packaged unit).
11. Automatic operation dramatically reducing maintenance cost thanks to reliable microprocessor system.
12. Complete safety protection:
a. High&low pressure protection, pressure safety value protection;
b. Overload protection to the compressor;
c. Power supply protect for phase lack, counter phase, voltage too high and voltage deficient;
d. Water system protection for freezing breaking, water lack etc.
Applicable Industries
Industrial Reaction Kettle Cooling
Central Air Conditioning System
Chemical Industry.
Plastic Injection Cooling -Pharmaceutical Industry
System Diagram
Model Details of Air Cooled Chiller:
Two Kinds of Models: Air Cooled Water Chiller/Air to Water Chiller
1. Design Cooling Condition: Chilled Water In/Out 12°C/7°C;Ambient 35°C
Models: LT03AS-40AD Cooling Capacity: 8KW-120KW
-Hermetic Scroll Compressors
-Tube in Tube Type Heat Exchanger for Evaporator
-V Type Fin Air Cooled Condenser
-Water Pump and Water Tank are an optional to built in the chiller
-Chilled Water Inlet/Outlet Temperature 12°C/7°C,Ambient 35°C
-Mostly Used for Central Air Conditioning Cooling
Remark: 1.Colling Condition: Chilled water in/out 12/7°C;Ambient Temperature 35°C;
2. Suitable chilled water temperature: 7-25°C;
3. Power supply: 3P-380V-50HZ; with voltage allowance ±10%, voltage dif between the phase lines±2%;
4.The data above is for R22, contact us if that for R134a,R407c and other refrigerant need;
5. There may be Changes for improvement without notice, confirm always before your order.
2.Cooling Condition: Chilled Glycol in/out -1/-5°C; ambient 35°C
Models: LT03ASL-40ADL Cooling Capacity: 4.7KW-61.6KW
-Hermetic Scroll or Semi-hermetic Piston Compressors
-Tube in Tube Type Heat Exchanger for Evaporator
-V Type Fin Air Cooled Condenser
-Water Pump and Water Tank are an optional to built in the chiller
-Chilled Glycol Inlet/Outlet Temperature -1°C/-5°C, Ambient 35°C
-Mostly Used for Industrial Processing Cooling
Remark:1.Designed Condition:Chilled Glycol in/out -1/-5°C; ambient 35°C;
2.This series units used in low temperature conditions, 25% ethylene glycol to be used as a refrigerant;
3.Power supply: 3P-380V-50HZ;with voltage allowance ±10%,voltage dif between the phase lines±2%;
4.The data above is for R22, contact us if that for R134a,R407c and other refrigerant need;
5.There may be Changes for improvement without notice, confirm always before your order.
Finished Products of Air Cooled Chiller:
Products in Warehouses:
LUTE Heat pump central air conditioning system
A. LUTE brand---china famous brand
B. Adopt import advanced American technology
C. Using world famous accessories as compressor etc
D. Designed by ourselves, own tens of design patents
E. Most energy saving and lowest running charge
F. Adopting environmental protection refrigerant as R134A, R22, R407C etc
G. Advocacy the government Energy-saving and emission-reduction policy
H. Apply for kinds of buildings for cooling, heating and making hot water
I.Most Advanced Testing and Inspection System and We Promise that Each Unit will Be Tested Over 48hours to Be Proved Qualified
J. We Solemn Promise Quick After Service and Very Priced with Highest Quantity
Products Certificate: