Industrial Usage Hanging intelligent thermometer SCW980 indicator

Industrial Usage Hanging intelligent thermometer SCW980 indicator

USD $1,050 - $1,100 /Set

Min.Order:1 Set

Supply Ability:
100 Set / Sets per Month
Port:
TIANJIN
Payment Terms:
Credit Card

Quick Details View All >

Place of Origin:
Hebei, China
Brand Name:
QIRUN
Model Number:
QR-SCW98
Usage:
Industrial
Theory:
Temperature Transmitter
Accuracy:
99.9%

Cangzhou Qirun Detecting Instrument Co., Ltd.

Business Type: Manufacturer,Trading Company
Cangzhou Hebei China
Main Products: Sampler ,Probe ,Fast Reaction Thermocouple

Product Details

 

 

SW98A

A:Temperature Instrument for Thermocouple

 It is connected with the thermocouple probe uesd for momitoring the temperature of molten metal for smelting and casting.

Technical Specification:

1.Measuring error:±0.2% ±1characters.

2.Working conditions:temperature 5-40°c relative humidity 85%

3.Storage conditions:temperature 0-45 °crelative humidity 85%

4.Power supply way:AC 220V ±10%;Frequency:50HZ± 2Hz

5.Power loss approximately: 50W

 

 
Type
                   SW-98A
Thermocouple Type
   S
  Wre3/25
    R 
        B
To test molten steel temperature range
1200°C-1769°C
1000°C-1999°C
1200°C1769°C
1200°C-1820°C
To test molten Iron temperature range
900°C-1769°C
900°C-1999°C
900°C-1769°C
900°C-1820°C
To test molten Copper temperature range
800°C-1769°C
800°C-1999°C
800°C-1769°C
800°C-1820°C
Continuous temperature-measuring range
0°C-1769°C
0°C-1999°C
0°C-1769°C
400°C-1820°C
 Display
Super bright LED display,High character 127mm(5 inches)or liquid crystal display
  Size
        410mm*300mm*95mm  
 Weight 
                      4kg
 

 

 The acousto-optics alarm:

a.The gree light bright expression thermcouple puts through,the measuring appliance enters the preparation condiction.

b.The yellow light brightly expressed the measuring appliance is surveying.

 

c.The red candle bright expressiong survey process ended,at the same time the electric bell inspires the sound,4-20mA or 1-5V analog output interface (specify when ordering),BCD at-large external display for the parallel interface

(specify when ordering),(Printer interface (specify when ordering)).

 
 
Packaging
Size
 410mm*300mm*95mm  
Weight
1.4kg
 
 
 
Packaging Details
The normal package is wooden box(Size: L*W*H). If container is too tigher,we will use pe film for packing or pack it according to customers special request.

B:Working principle

Turn on the power after, thermocouple input when open, instrument in the clock display state.

Through to the thermocouple, prepare light(green light), meters from the clock display state the standby state,The screen display input temperature (cold end temperature) When thermocouple insert metal 1 to 2 seconds solution, yellow lights up, measurement instrument enter into the state, computer automatic find temperature platform. After balance a red light, electronic device ring, said end of measurement, and remind the operator carry guns.

Measurement end.

 

 

 
 
 

C:Instrument self-inspection


 

Prompt:

E-A Analog fault

Reason:

Instrument working environment temperature is too high, analog circuit components damage, the general situation for input into high pressure interference makes 4052 4053 or damage 

Prompt:

E-S Parameters set wrong

Reason:

Platform allows fluctuation or platform sampling time to dial the code switch contact undesirable or zero, two parameters any one party problems will appear E-S

Prompt:

E-P Print circuit fault

Reason: General is external printer malfunction

Prompt:

E-L Cold end compensation fault

Reason:

The cold end compensation devices AD590 to damage, line contact undesirable, analog circuit is part of the 4053 damage.

 

 


D:The basic parameters and structure

Type
SCW-98A
Graduation
S
D
R
B
Temperature range:
1200-1769
1000-1999
1200-1769
1200-1820
Continuous measuring temperature range
0-1769
0-1999
0-1769
400-1820
External Port
1.Print port 2. Bell 3 Isolator BCD code 4Analogue port
display screen
Three and a half display ,Text height 127mm, High-brightness red LED
size
410mm*300mm*95mm hooking distance:230mm
Structure
Wall hanging
Weight
4KG
 

E : Floor schematic diagram and description

 

F: Instrument calibrated

1. Clock adjustment

Instrument on the front panel has three button to select button, respectively raised button, cut button. Adjust the time, we should take thermocouple signals input to open, or button function failure. When the press when the choice, instrument display content to choose for quantity that can in turn make screen shows month, day, and minutes. According to rise or fall can make the display value should be adjusted to the value set, then press the choice to switch to the display value next to the amount of choice, then press rise or fall to to set data, which in turn by choice, raised or cut until complete adjustment.

2. Measurement state set:( Need this function, should be in order.)

Instrument on the front panel has a function selection switch, choose the working state of the instrument, when switch to rapid temperature measurement gear, instrument and rapid temperature measuring thermocouples used together, in the rapid temperature before, when the switch to continuous files, and supporting the use of the industrial thermocouple, continuous determine the temperature of the object to be tested.

Special remind users note: whenever this switch state changes, should make thermocouple signal input to open a or make instrument to electricity, the measurement condition to convert to is invalid.


3.Measuring parameters set(Dial the code switch is set)

Instrument host board has two groups of four dial SW1, SW2 code switch.

SW1 used to set the time dynamic sampling instrument platform, SW2 used to set sampling instrument dynamic platform width (namely the maximum allowed fluctuation)

Dial the code switch your a right arrangement for 8421, dial the code switch on 4 corresponding binary right 8, 3 corresponding binary right 4, 2 corresponding bits 2, 1 corresponding right bits right 1, each group of each has 16 (0-15) code. Platform allows fluctuation representative number 1 degrees Celsius. Maximum allowable values 15 degrees Celsius,

Effective time value each number platform on behalf of 160 ms (for two samples values) the specific set parameters according to this unit by the customer specific process required, usually set parameters recommended in the list below.


Measuring objest
Platform fluctuation allow℃
SW2(Value)
Platform sampling time(ms)
SW!(Value)
Before converter
8-10
8-10
160*3=480
3(6 samples)
Before furnace
8-12
8-12
160*3=480
3(6 samples)
Continuous casting
5
5
165*5=800
5(10 samples)
Before electric furnace
8-10
8-10
160*3=480
3(6 samples)
Steel ladle
5-8
5-8
160*4=640
4(8 samples)

Platform sampling time (SW!)                                                 Platform fuctation allow (SW2)            


4. Graduation Choose

Intelligent instrument is equipped with four points degree number(B/S/R/D or B/S/R/K)



On the main board inside machine with dividing, choose switch, in a printer interface of flank, use short way switch. The user can according to the circuit board with the dividing and corresponding short way to set by way, as below:


Remind users note: whenever selecting finished, should make instrument to power meter input or will open a thermocouple, otherwise the new choice is invalid.


Contact Supplier

Mr. Peixiu Wang General Manager Chat Now
Telephone
86-0317-8622168,13931715513
Mobile
13931715513
Fax
86-0317-8621346
Address
Nanpi County,Xuheyang Village,Wumaying Town Cangzhou,Hebei

You May Like

New Products

Recommended Products

View More View Less

Find Similar Products By Category

Measurement & Analysis Instruments > Temperature Instruments
Categories
Hi~