Compound Sublance Probe
USD $20 - $100 /Piece
Min.Order:60 Pieces
Cangzhou Qirun Detecting Instrument Co., Ltd.
Cangzhou Qirun Detecting & Instrument Co., Ltd
Compound Sublance Probe
Usage:
The Compound Sublance Probe is used for temperature and sample of molten steel in the converter,which has advantage for quick,accurate,direct measurement and auomatic control in steel making process.
Specification:
1)Type:QR-TOS
TOS With steel temperature measurement,oxygen content and sampling three functions.
2)Type:QR-TCS
TCS With steel temperature measurement,carbon content and sampling three functions.
3)Type:QR-TCOS
TCOS With steel temperature measurement,carbon content,oxygen content and sampling four functions.
Temperature measuring:
Range:1450°c-1750°c
Tolerance:5°c
Measuring Time:≤5s
Oxygen activity measuring:
Range:100-1300ppm
Tolerance:10%
Measuring Time:<8s
Carbon contect measuring:
Range:A)when<0.20% Tolerance:0.02%
B)when 0.02%-0.05% Tolerance:0.04%
C)when>0.05% Tolerance:0.06%
Mwasuring Time:<8s
Our products through the the ISO international quality certification.