Iron/Copper Bar Use Induction Heating Furnace
USD $1,000 - $90,000 /Set
Min.Order:1 Set
Yiphee Electric Furnace Co., Ltd.
Iron/Copper Bar Used Induction Heating Furnace
Our Services
Power | KW | 50KW | 100 KW | 160KW | 250KW | 350KW | 500KW | 800KW | 1000KW | 1250KW | 1500KW | 2500KW |
Rated input voltage | V | 380V | 380V | 380V | 380V | 380V | 380V | 380V 380V-2 | 380V 380V-2 | 660V 380V-2 | 660V 380V-2 | 1000V 660V-2 |
Phases of input Power |
| 3 | 3 | 3 | 3 | 3 | 3 | 3/6 | 3/6 | 3/6 | 3/6 | 3/6 |
Frequency of Input Current | HZ | 50/60 | 50/60 | 50/60 | 50/60 | 50/60 | 50/60 | 50/60 | 50/60 | 50/60 | 50/60 | 50/60 |
Rated input Current | A | 80A | 160A | 256A | 400A | 560A | 800A | 1280A 640A | 1600A 800A | 1120A 1000A | 1350A 1200A | 2000A 1120A |
electricity power supply(recommend) | KVA | 60KVA | 120KVA | 200KVA | 315KVA | 400KVA | 500KVA | 800KVA 1250KVA | 1250KVA 1500KVA | 1500KVA 1800KVA | 1800KVA 2000KVA | 3000KVA 3500KVA |
Rated output voltage | V | 750V | 750V | 750V | 750V | 750V | 1500V | 1500V 2500V | 1500V 2500V | 2500V
| 2500V | 3500V |
Rated output frequency | HZ | 2-8KHZ | 2-8KHZ | 1-8KHZ | 1-4KHZ | 1-2.5KHZ | 1KHZ | 0.8KHZ | 0.8KHZ | 0.7KHZ | 0.7KHZ | 0.5KHZ |
Heating Furnace Cavity Temperature (Steel) | ℃ | 1200℃ | 1200℃ | 1200℃ | 1200℃ | 1200℃ | 1200℃ | 1200℃ | 1200℃ | 1200℃ | 1200℃ | 1200℃ |
Heating Furnace Cavity Temperature (Copper) | ℃ | 900℃ | 900℃ | 900℃ | 900℃ | 900℃ | 900℃ | 900℃ | 900℃ | 900℃ | 900℃ | 900℃ |
Heating Furnace Cavity(Aluminium) Temperature | ℃ | 500℃ | 500℃ | 500℃ | 500℃ | 500℃ | 500℃ | 500℃ | 500℃ | 500℃ | 500℃ | 500℃ |
Production (Steel) | Kg/h | 125 | 249 | 398 | 622 | 871 | 1245 | 1992 | 2490 | 3112 | 3735 | 6220 |
Production(Copper) | Kg/h | 282 | 564 | 902 | 1410 | 1974 | 2820 | 4512 | 5640 | 7050 | 8460 | 14100 |
Production(Aluminium) | Kg/h | 234 | 468 | 748 | 1170 | 1638 | 2340 | 3744 | 4680 | 5850 | 7020 | 11700 |
Power Consumption Per Ton(Steel) | Kw.h/T | 350-550(Relation to Power, Frequency,Temperature,Shape,Density and Furnace Body Holding) | ||||||||||
Power Consumption Per Ton(Copper) | Kw.h/T | 150-300(Relation to Power, Frequency,Temperature,Shape,Density and Furnace Body Holding) | ||||||||||
Power Consumption Per Ton(Brass) | Kw.h/T | 130-270(Relation to Power, Frequency,Temperature,Shape,Density and Furnace Body Holding) | ||||||||||
Power Consumption Per Ton(Aluminium) | Kw.h/T | 180-400(Relation to Power, Frequency,Temperature,Shape,Density and Furnace Body Holding) | ||||||||||
Cooling water consumption | T/h | 3 | 5 | 8 | 10 | 11 | 15 | 20 | 25 | 28 | 35 | 43 |
Input Water Pressure | MPa | 0.2 | 0.2 | 0.2 | 0.2 | 0.2 | 0.2 | 0.2 | 0.2 | 0.2 | 0.2 | 0.2 |
Weight | KG | 350 | 550 | 900 | 1200 | 1500 | 2000 | 3000 | 3500 | 4500 | 5500 | 6000 |
Volume | M3 | 3 | 3.5 | 3.6 | 4 | 5 | 5.5 | 6.5 | 7.5 | 9.5 | 11.5 | 13 |