Class II N-PE Wind Power Generation Lightning Arrester
Class II N-PE Wind Power Generation Lightning Arrester
Class II N-PE Wind Power Generation Lightning Arrester
Class II N-PE Wind Power Generation Lightning Arrester
Class II N-PE Wind Power Generation Lightning Arrester
Class II N-PE Wind Power Generation Lightning Arrester

Class II N-PE Wind Power Generation Lightning Arrester

USD $60 - $80 /Set

Min.Order:1 Set

Supply Ability:
50000 Set / Sets per Month
Port:
Conton/shanghai/changsha
Payment Terms:
T/T L/C D/P D/A Credit Card

Quick Details View All >

Place of Origin:
Hunan, China
Brand Name:
ZHONGPU SHENGDE
Model Number:
DXH06-F/3+1AC690R30

Hunan Zhongpu Lightning Protection Co., Ltd.

Business Type: Manufacturer,Trading Company
Zhuzhou Hunan China
Main Products: Surge Protection Device ,Power Supply SPD ,Surge Protector ,Lightning Protection Device ,AC Surge Protector

Product Details

Class II N-PE Wind Power Generation Lightning Arrester

 

1. APPLICATION

         Huge energy released by the lightning would cause the wind turbine blades damaged, insulation breakdown, control components overburdened, etc. Therefore wind power SPD has became one of the powerful guarantees for safe and normal operation of the wind turbine.

 

2.TECHNICALS PARAMETERS

 

Model DXH06-F/

3+1AC690R30

3 AC690R30

Type (IEC 61643-1)

Class II /Type 2

Max. Continuous Operating Voltage(Uc)

1000VAC

750VAC

Nominal Continuous Operating                        Voltage(Un)

690VAC

690VAC

Nominal Discharge Current Capacity (In)

15kA(8/20μs)

Max. Discharge Current Capacity (Imax)

30kA(8/20μs)

Protection Mode

L~PE

Protection Level(Up)

≤4.2kv

≤3.0kv

Response Time(T)

<25ns

Fault Indicator

Available

Live Line(mm² )

≥6

Earth line(mm² )

≥10

Grounding Resistance(R)

≤4Ω

Protection Level of the Shell

IP20

Operating Temperature

-40~+70

Overall Size(mm)

144×90×68

54×90×65

Installation Method

35 mm DIN-rail

 

Class II N-PE Wind Power Generation Lightning Arrester

 3Wiring Diagram

 

Class II N-PE Wind Power Generation Lightning Arrester

 

Class II N-PE Wind Power Generation Lightning Arrester

 

4. Installation Method and Attentions

 

1) Wiring as shown in Figure;

 

2) The connecting lead shall use many strands of copper wires of more than 6mm2, and the earth wire shall use many strands of copper wires of more than 10mm2. The connecting wire shall be as short, straight and coarse as possible. Grounding Resistance should be no less than 4Ω;

 

3) The front of lightning arrester shall be connected with proper fuse in series or be opened;

 

4) The power supply must be cut off while conducting the installation. It is prohibited to conduct the operation with the charge. The connecting lead must conform to the requirement;

 

5) After completing the installation, the lightning protection module shall be inserted tightly and inspected;

 

6) When there is RED for the fault indicator of the lightning arrester module (warning signal of remote-signaling port), it indicates that the lightning protection module has degraded and shall be replaced;

 

7) The SPD needn't special maintenance, but only check the connection and indicating state periodically.

 

Class II N-PE Wind Power Generation Lightning Arrester

 

5. Certificates:

 

Class II N-PE Wind Power Generation Lightning Arrester

 

 

Class II N-PE Wind Power Generation Lightning Arrester

Contact Supplier

Ms. Derain Tan manager Chat Now
Telephone
86-0731-22461398
Mobile
13786358332
Address
Bldg 5, SME Promotion Park Zhuzhou,Hunan

You May Like

New Products

Recommended Products

View More View Less

Find Similar Products By Category

Electrical Equipment & Supplies > Other Electrical Equipment
Categories
Hi~