Temperature Meter for lamp caps. It's used to test the working and environmental temperature as well as temperature rise
Negotiable /Set
Min.Order:1 Set
Shenzhen Chuangxin Instruments Co., Ltd.
Lamp Cap Temperature Rise Test System
CX-T1 is according to IEC60360-1998 and GB2512-2001(Standard method of measurement of lampcap temperature rise). It is used to test the working and environmental temperature as well as temperature-rise of the burner and lamp. It meets the requirement of IEC and GB Standards
• Channel sequence is displayed by 2 LED and temperature is displayed by 4 LED; Simultaneously display temperature rise curve
• Sensor: K type thermocouple and 8 channels for input temperature signal
• Temperature range: -40~300°C and testing accuracy: Class 0.5
• Capable of circle monitoring, single monitoring, printing and RS-232-C communication with PC
• Freely set up for channel sequence when circle monitoring
• Application software in Windows can track the changing of the selected channel temperature and provide print and save operation
• Dimension of standard testing box: 90x90x90cm (inner box) and 105x105x120cm (outer box), or customized; Lamp holder: E14, E27, E40, B22d and other holders