Brass underfloor heating manifold with 2 to12 ways valve not leaking manual automatic temperation controller
Brass underfloor heating manifold with 2 to12 ways valve not leaking manual automatic temperation controller
Brass underfloor heating manifold with 2 to12 ways valve not leaking manual automatic temperation controller
Brass underfloor heating manifold with 2 to12 ways valve not leaking manual automatic temperation controller
Brass underfloor heating manifold with 2 to12 ways valve not leaking manual automatic temperation controller
Brass underfloor heating manifold with 2 to12 ways valve not leaking manual automatic temperation controller

Brass underfloor heating manifold with 2 to12 ways valve not leaking manual automatic temperation controller

USD $29 - $350 /Set

Min.Order:500 Sets

Supply Ability:
5000000 Set / Sets per Month
Port:
Ningbo or Shanghai
Payment Terms:
T/T Credit Card

Quick Details View All >

Standard or Nonstandard:
Standard
Structure:
Ball
Pressure:
Medium Pressure
Power:
Manual
Material:
Brass
Temperature of Media:
Medium Temperature

Shanghai Weiqin International Trade Co., Ltd.

Business Type: Trading Company
Shanghai China
Main Products: Valve ,Manifold ,Flange ,Copper Strainer ,Faucet

Product Details

Specifications

Brass Union Manifold for heating,with Red-bronze color 
Material: brass 
size: 1/2'' 3/4 ''  1'    2-12 loops (any another kinds style can be made as your order, OEM can be receipted )
Package:carton 
Min order: 1pc

Brass Union Manifold for heating,with Red-bronze color  

1Product Description / Application

 

 

Brass Union Manifold for heating,with Red-bronze color always used in  under floor heating system.

 

For distribution and regulation of the volume of the various heating circuits in low temperature heating and cooling systems (e.g. floor or wall heating).

 

 

-      Manifold is made up of the precision matched components with flat-seal connections

 

-       Volume control carries out using a square venting key on the control valve

 

-       Adjusted flow can be read off directly by the flow meter with integrated shut-off device

 

 

 

 The New Characters of Brass Union Manifold for heating,with Red-bronze:

Brass underfloor heating manifold with 2 to12 ways valve not leaking manual automatic temperation controller

Brass underfloor heating manifold with 2 to12 ways valve not leaking manual automatic temperation controller

                      Character of the  Brass Union Manifold for heating,with Red-bronze color  

 

<1>main bars.
With strong 
three-dimensional sense on the main bar ,and remarkable in comparison with ordinary products .

<2> o-rings.
2 0-rings +PTFE Packing.
 Even if the two O-rings has been damaged all, the leakage will stop immediately after tighten the locking cap, thereby greatly reducing  the inconveniences to the users during the heating time.

 
<3>Seal seat.

PTFE shut off seat can shut tight.

 

<4>Branches.
The
 main bar and branch have been integrated with  excellent  leak-proof  technology and  stability , which can guarantee no connection points, thus completely solve quality problems due to improper production and construction. 

 

<5>Handle wheel
Plug 
Hand wheel ---Pull up the hand wheel and remove it when leakage .More convenience for facilitate maintenance.

  <6 > Connections
The connections  of floor heating pipe are  union structure .All types of pipes are interchangeable for style 1216,1620,20*2.3 ,which increase the versatility character of the pipes.

 <7> Exhaust valves 

Union structure for vent and body . Less leakage , safe use .  Precise positioning with lock- cap structure.

 

  Brass underfloor heating manifold with 2 to12 ways valve not leaking manual automatic temperation controllerBrass underfloor heating manifold with 2 to12 ways valve not leaking manual automatic temperation controller

2         Technical specifications / Operation conditions

 

 

 

2.1    Heating circuit manifold

 

Material:

 

-       Made of Brass pipe Hpb 59-1, Copper and copper alloys - Plate, sheet, strip and circles for general purposes]

 

-       All valve inserts and connecting fitting completely nickel-plated or brass nature color

 

 

 

Description and dimension:

 

-       Supply (above) and return (below) bars 1”.

 

-       Distance between heating circuits 48mm

 

-       Distance between supply- and return bars 200mm 

 

-       Quantity of heating circuits: 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12

 

 

 

In the manufacturing process of the manifold incl. all components a pressure as well as a function test have to be performed.

 

 

Technical data:

 

 

 

-       Max. operating temperature: 100 °C(212℉)

 

 

 

 

 

 

 

-       Min. operating temperature: -20 °C(-4)

 

 

 

-       Max. operating pressure:  6 bar

 

 

 

-       Max. test pressure (24 h, < 30 °C): 10 bar

 

 

 

-       Flow ranges of the flow meter: 0 - 5 l/min

 

Your inquiry is welcome and please do not hesitate to contact  us if your have any question or need .OEM can cooperate.

 

Contact Supplier

Ms. Vivian Li Manager Chat Now
Telephone
0086-21-60448203
Mobile
86018916546667
Fax
0086-21-58308950
Address
Room 203,Floor 2th,Building A , Fute West Road 1 , Pilot Free Trade Zone,Shanghai ,China Shanghai

You May Like

New Products

Recommended Products

View More View Less

Find Similar Products By Category

Mechanical Parts & Fabrication Services > Valves
Categories
Hi~