R410A,R407C Europe standard swimming pool heating heat pump water heater horizontal and vertical type
USD $800 - $900 /Piece
Min.Order:1 Piece
Guangdong Luckingstar New Energy Co., Ltd.
R410A,R407C Europe standard swimming pool heating heat pump water heater horizontal and vertical type
Specifications | ||||||||
Model | LWH-100SC | LWH-150SC | LWH-200SC | LWH-250SC | LWH-300SC | LWH-400SC | ||
Heating & Cooling System | Heating capacity | kW | 45.7 | 68.6 | 91.5 | 114.5 | 145 | 190 |
Btu/h | 153000 | 233000 | 311000 | 389000 | 493000 | 646000 | ||
COP | 5.71 | 5.7 | 5.71 | 5.72 | 5.7 | 5.8 | ||
Cooling capacity | kW | 30 | 45 | 60 | 75 | 100 | 130 | |
Btu/h | 102000 | 153000 | 204000 | 255000 | 340000 | 442000 | ||
EER | 3.23 | 2.78 | 2.73 | 2.80 | 3.2 | 2.9 | ||
Max outlet water temp | °C | 45 | ||||||
Power & Current | Power supply | V/Ph/Hz | 380~415V/3PH/ 50Hz (460V/3Hz/60Hz) | |||||
Rated input power(Heating/Cooling) | kW | 8/9.3 | 12/16.2 | 16 /22 | 20/26.8 | 25.4/31.2 | 32.7/44.8 | |
Rated input current(Heating/Cooling) | A | 15.2/17.6 | 22.8/30.7 | 30.5/41.8 | 38/50.8 | 48/59.2 | 62/85 | |
Compressor | Type | Scroll*2 | Scroll*2 | Scroll*2 | Scroll*2 | Scroll*2 | Scroll*4 | |
Brand | Copeland | |||||||
Throttle type | Electronic expansion valve (EEV) | |||||||
Fan/Motor | Fan type | Low noise high efficiency axial type | ||||||
Fan direction | Vertical | |||||||
Fan No. | 2 | 2 | 2 | 2 | 4 | 4 | ||
Fan input power | W | 250 | 550 | 750 | 750 | 750 | 750 | |
Fan speed | RPM | 850 | 910 | 940 | 940 | 940 | 940 | |
Evaporator | Fin type | Hydrophilic aluminium | ||||||
Tube type | mm | Innergroove tube | ||||||
Condenser (Heat exchanger) | Type | Titanium in PVC | ||||||
Quantity | 2 | 2 | 2 | 2 | 4 | 4 | ||
Max pressure | MPa | 2.8 | ||||||
Controller | Type | Intelligent & LCD | ||||||
Set Temp. | °C | 25 ~ 45 | ||||||
Ambient Temperature | °C | (-10°C ~ +45°C) | ||||||
Refrigerant | Type | R417A/R407C/R410A | ||||||
Discharge pressure | Mpa | 2.5 | ||||||
Suction pressure | Mpa | 0.3 ~ 0.8 | ||||||
High pressure gauge | Yes | |||||||
Protection system | Low pressure protection | Yes | ||||||
High pressure protection | Yes | |||||||
Automatic defroting system | Yes | |||||||
Overload protection | Yes | |||||||
Water system | Rated water pressure | Mpa | 0.2 ~ 0.6 | |||||
Water flow volume | m3/h | 13 | 19 | 25 | 31 | 40 | 50 | |
Water pipe size | mm | 63 | 63 | 90 | 90 | 110 | 110 | |
Noise in 1 meter | dB(A) | ≤60 | ≤65 | ≤66 | ≤68 | ≤71 | ≤72 | |
Cabinet | Stainless steel / Galvanized powder coated steel | |||||||
N.W | kg | 270 | 460 | 620 | 720 | 900 | 1100 | |
G.W | kg | 320 | 510 | 700 | 800 | 1000 | 1200 | |
1. Heating working condition: Outdoor DB/WB temp: 24°C/19°C,62.5%RH, inlet water temp:26°C. | ||||||||
2. Cooling working condition: Outdoor DB/WB temp: 35°C/24°C,68%RH, inlet water temp:30°C. |