TH-1000 Laboratory Conditioning Chamber Technical Parameters :
1 | Model:TH - 1000 | |||
2 | Dimension: | |||
1.Interior Dimension : 100 x 100x 100CM ( WxHx D ) | ||||
2.Exterior Dimension : 160 x 210x 145CM (W x H x D) | ||||
3 | Temperature Range: | |||
1.Temperature: -70 °C ~ 100°C(adjustable) | ||||
2.Humidity: 20% ~ 98% R.H. (adjustable) | ||||
4 | temperature rising falling speed rate: | |||
1. 0°C(R.T.) <---------> 100 °C approx.40 mins(approx.3.0°C/min) | ||||
2. 25°C(R.T.) <---------> 0 °C approx.70 mins (approx1.0°C/min) | ||||
5 | Machine accuracy: | |||
1.Analytic accuraty: | ||||
Temperature: 0.1 °C | ||||
Humidity : 0.1 % R.H | ||||
2.Control accuracy : | ||||
Temperature :± 0.5°C | ||||
Humidity : ±2.5%RH | ||||
3.Distribution uniformity: | ||||
Temperature:±2.5°C(when temperature is 100°C) ±3.5°C(when temperature is 150°C) | ||||
Humidity:±3.5%(75% higher)±4.5%(75%lower) | ||||
6 | Humidity control range: | |||
7 | Structure: | |||
1.Graceful appearance, circularly shaped body, surface treated with mist strips and plane handle with no reaction. Easy to operate, safe and reliable. | ||||
2.Interior material:SUS#304 stainless steel , mirror polishing. | ||||
3.Exterior material:SUS#304 stainless steel. | ||||
4.Insulation Material:Resistant to high temperature, high density, formate chlorine, ethyl acetum foam insulation materials. | ||||
5.Test hole: One hole (Dia.50mm) on left side of chamber, for connecting outside 's powerline or signal line. | ||||
8 | Control system: | |||
1.Imported LCD display screen, capable of displaying the measured value as well as the set value and time. | ||||
2.Fixed condition or programmable condition can be set. | ||||
3.Fixed condition setting time range: 0 - 99 H 59 MIN . | ||||
4.Programmable mold can set 10 different programe at the same time, each programe can set 10 step to do cycle testing, total is 100 steps different temperature,humidity and testing time. | ||||
5.Each step runing time (99 hr 59 min), Max.can do 999 times cycle. | ||||
6.With power off memory device, reply message to continue with the rest of the program. | ||||
7.The control unit has the functions of multiples segment program editing, and of quick or slope control of temperature and humidity. | ||||
8.With TIMER SIGNAL OUTPUT RELAY. | ||||
9.Temperature sensor adopt DIN PT-100Ω | ||||
10. Adpot BTHC system to control temperature and humidity , P.I.D. control S.S.R.. | ||||
11.With P.I.D. auto calculate funtion. | ||||
12. With alarm function when runing or setting fault. | ||||
13. 5 years memory back up device while power off | ||||
14.With LOCK function for interface. | ||||
15.Recorder is optional | ||||
16.This system conform to constant temperature humidity reliablity test standard:CNS,ISO,JIS,ASTM,DIN,BS,IEC,NACE,UL,MIL… | ||||
9 | Cooling system: | |||
1.Impoerted power saving full closed compressor | ||||
2.Cooling method: air cooling. | ||||
3.Imported dry filter,electrol valve.,etc freeze accessories. | ||||
4.Air cooling type Conder,attached with heat dissipation moter device or water cooling pipe. | ||||
5.Ryogenic system adopts dual refrigeration loop, fast cooling. | ||||
6.Expansion system: capillary capacity control refrigeration system. | ||||
10 | Heated humidification system: | |||
1.Adopt U-TYPE SUS#304ss Electric heat pipe heater | ||||
2.Humidify barrel made of SUS#304ss,with observation glass and electromagnetic valve of water level | ||||
3.Idepently heat,wet humidify,dehumidify system. | ||||
4.With auto heating,wetting and demist function,with observation glass and imported tube. | ||||
4.Humidification water recycling, automatic filling water system,25L built in draw-out type water tank . | ||||
11 | Saftey device: | |||
1.With no-fuse protection switch | ||||
2.Over-heat protection | ||||
3.Ceramics E-16 fuse | ||||
4.high low temperature protection switch for compressor | ||||
5.over heat swith for compressor | ||||
6.Water shortage alarm, stop machine for long time water shortage protection. | ||||
12 | Accessories : | |||
2 pcs SUS#304ss sample setting sheives, 5 pcs wet and dry bulb gauze five, 4 pcs universal wheel,4 pcs horizontal foot cup. | ||||
13 | Warranty: | |||
1 year warranty for the full system of machine (except for natural disasters or man-made damage), life-long maintenance. | ||||
14 | Attached documents : | |||
(1)Operating instruction manual, warranty card; | ||||
(2)Personnel training operation. | ||||
15 | Power: | |||
AC220V 50/60Hz | ||||
16 | P.S.: | |||
(1)The operating environment of the machine should be under room temperature and with good ventilation. We strongly suggest to install air conditioner in the working area. |
...