Rapit Temperature change Test Chamber
USD $1,900 - $5,000 /Set
Min.Order:1 Set
Dongguan ASLi Test Instrument Co., Ltd.
Rapit Temperature change Test Chamber
Temperature Quick Change Chamber /application:
Rapid Temp. Changes Environmental Test Chamber is applied to find hidden mechanical weaknesses in electronic components when test specimens are exposed to rapid temperature change conditions
Inner door with operation hole (optional)
Travelling cable port Dia.50mm or 100mm
Sample Shelves, two layers
RS-232 or RS-485 communication
Temperature Rapit Change Chamber /features:
1.Graceful appearance, circularly shaped body, surface treated with mist strips, and plane handle with no reaction. Easy to operate, safe and reliable.
2. Rectangular viewing window for the observation of product under test, equipped with sweat-proof electrical heating device that can prevent water steam from condensing into droplets, and with high brightness PL fluorescent bulbs to provide light inside the box.
3.Double-layer-insulated airtight doors, able to insulate the internal temperature effectively.
4.Water supply system that is externally connectable, convenient for refilling water into the humidifying pot and automatically recyclable.
5. French Tecumseh is used for the compressor circulation system, capable of removing the lubricant between the
condensation pipes and capillaries. environment friendly coolant is (R23,R404A)
6.LCD display screen is used for the control unit, capable of displaying the measured value as well as the set value and time.
7. The control unit has the functions of multiples segment program editing, and with temperature ramp
8. Casters for ease of mobility, with strong positioning screws.
Rapit Temperature Change Chamber /technical parameters:
Model | F-TH-150(A~F) | F-TH-225(A~F) | F-TH-408(A~F) | F-TH-800(A~F) | F-TH-1000(A~F) |
Internal Dimension WxHxD( mm) | 500x600x500 | 600x750x500 | 600x850x800 | 1000x1000x800 | 1000x1000x1000 |
Internal Dimension WxHxD (mm) | 1100x1750x1600 | 1200x1800x1700 | 1250x1900x1900 | 1600x2050x2150 | 1700x2200x2300 |
Range of Fast Temperature Change | Temperature Range: -70~+150°c; Range of Fast Temperature Change: -45~+85°c; Max. temperature rising/falling velocity is 15°c /min with linear control . | ||||
Humidity Range(Optional) | 20%~98%R.H.(10%-98% R.H. / 5%-98% R.H. ,is optional ,need Dehumidifier) | ||||
Indication Resolution/ Distribution Uniformity of Temperature and Humidity | 0.1°c; 0.1% R.H/±2.0°c; ±3.0% R.H. | ||||
Control Accuracy of Temperature and Humidity | ±0.5°c; ±2.5% R.H. | ||||
Temperature Rising/ Falling Velocity | The Temperature Rising/Falling Velocity is 3~15°c/min, with linear control ,adjustable; is 3~30°c/min, adjustable, with non-linear control | ||||
Internal and External Material | Internal Material is SUS 304# stainless steel,external material is stainless steel or SEE cold-rolled steel with paint coated. | ||||
Insulation Material | Resistant to high temperature, high density, formate chlorine, ethyl acetum foam insulation materials | ||||
Cooling System | Water cooled, single segment compressor | ||||
Protection Devices | Fuse-free switch, overloading protection switch for compressor, high and low voltage coolant protection switch, over-humidity and over-temperature protection switch, fuses, fault warning system, water short storage warning protection | ||||
Optional Accessories | Inner door with operation hole(Optional), Water Purifier, Dehumidifier | ||||
Compressor | French Tecumseh , Germany Bizer | ||||
Power | AC380V 50/60HZ | ||||
Weight(Kg) | 250 | 350 | 450 | 600 | 700 |
More pictures of Rapit Temperature change Test Chamber