Saline Test Chamber
USD $2,000 - $10,000 /Set
Min.Order:1 Set
Dongguan ASLi Test Instrument Co., Ltd.
Saline Test Chamber
ASLi, as a leading saline test chamber supplier from China, has more than 25 year's experience in saline test chamber manufacture. ASLi boost his own technical team in saline test chamber R&D, and it also introduces the advance quality control method in saline test chamber production. Our saline test chamber series products are in compliance with the industrial standards, IE, ISO, ASMT, DIN, EN, GB, BS, JIS, ANSI, UL, TAPPI, AATCC, IEC, VDE, CSA and CEN.
Saline Test Chamber Features
1. Adopt humidity and temperature controller with LCD touch screen digital display, R232 or R485 communication interface. (Temperature and humidity recorder, can keep complete records of the humidity and temperature graphs. This is optional.)
2. Salt spray test chamber operation mode: programmable or constant
3. Capacity of programmable operation is 100 groups 100 steps per group, and 100H per step
4. Capacity of constant operation is 10000H.
5. Memory function: in case of a power cut, the machine can resume the unfinished test as soon as power is recovered.
Saline Test Chamber Technical Parameters:
Model | SH-60 | SH-90 | SH-120 | SH-160 | SH-200 | ||||
Internal Dimension WxHxD (mm) | 600x450x400 | 900x600x500 | 1200x800x500 | 1600x800x500 | 2000x1000x500 | ||||
External Dimension WxHxD (mm) | 1100x600x1200 | 1400x950x1200 | 1900x1300x1400 | 2300x1300x1400 | 2700x1500x1500 | ||||
Lab Temperature | Saline test (NSS ACSS) 35±1 °C ;Corrosion Test (CASS)50±1 °C | ||||||||
Pressure Bucket Temperature | Saline test method (NSS ACSS) 47±1 °C / Corrosion Test (CASS)63±1 °C | ||||||||
Lab Capacity(L) | 110 | 270 | 500 | 800 | 1500 | ||||
Saline Capacity(L) | 15 | 25 | 40 | 40 | 40 | ||||
Saline Concentration | 5% concentration of NaCl, or every Liter 5% NaCl add 0.26g CuCl2H2O | ||||||||
Compressed Air Pressure(Kgf) | 1.0~6.0 | ||||||||
Spray Volume | 1.0~2.0ml /80cm2 /h(working at least 16 hours, and take the average value) | ||||||||
Spray Form | Continuous Spraying or Programmable Spraying | ||||||||
Power | AC220V 1 Ph 3 lines15A | ||||||||
Weight(Kg) | 65 | 80 | 120 | 160 | 200 |
Application:
Salline test chamber is used for imitating natural status in increase imitation test. The imitating condition is harder than status that we usually meet. The tester can combine the follow status such as: salt smog, dry, humidity, normal temperature, low temperature.The tester is for product used in intense changeable environment.
such as: parts of automobile, navigation equipment, camera equipment, building material, electroplate coating and resistant to metal electrolytic corrosion in electrical system.
More Saline Test Chamber pictures for your reference :
...