100mA Radiology and Fluoroscopy Equipment & Accessories
USD $1,400 - $1,800 /Piece
Min.Order:1 Piece
Qinhuangdao Kit Alexa Medical Trading Co., Ltd.
100mA Radiology and Fluoroscopy Equipment & Accessories
Use of the 100mA Medical Xray machine:
Fluoroscopy
Digestive track spot film radiography
General radiography
Filter-ray device radiography
Main Characteristics of the 100mA Medical Xray machine:
1. This 100mA Medical Xray machine is Single bed and single tube.
2. Design according to the electric medhanism of middle-size machine. The function is full and
reasonable.
3. The high-tension system is of march-past structure. Equipped with afullwave rectification high-
voltage generator
and ifdependent X-ray tube unit, with large output power and reliable and stable operation.
4. Supply voltage V, roentgenoscopy, photograpy kV and stepless adjustable.
5. Equipped with the manostat for filament of X-ray tube and the spacecharge compensator as to
ensure the stable
and accurate output.
6. Equipped with the capacity limitation and protection circuit and kV mA s interlock limitation and
protection.
7.Adopt the digital circuit timer, grade according to R10 prioritycoefficient and can control time
exactly.
8. Diagnostic bed id of electric back rotation and is equipped with vibrating filter-ray device.
9. The spot film device of fluoroscent screen of the 100mA Medical Xray machine can hole the film
jecket of various
sizes and can make the photograpy of full-film and half films separately.
10. The upright post of the 100mA Medical Xray machine has the bottom track only, which is easy
while instalation.
Main Technical parameter:
1.Power supply:
Adjustable range:With power supply 380V 340V-420V;With power supply 220V 195V-250V
2.Fluoroscopy:
Adjustable range of tube voltage:50~95kV (Can adjust continuously)
Adjustable range of tube current:0.5~5mA (Can adjust continuously)
3.Radiography:
Adjustable range of tube voltage:50~100kV (Can adjust continuously)
Adjustable range of tube current:Small focus: 50mA;Big focus: 50, 100, 150 and 200mA
Tube current of spot-film:150mA (fix)
Adjustable range of time:0.04~6.3s,23 grades together
4.High-voltage Generator unit:
Max. DC output voltage:100kV
Max. DC output current:200mA at instant;5mA at running
5.X-ray tube:
Focus:1mm×1mm,2mm×2mm
Rotary angle:+90°~0°~-5°
Move range of gastrointestinal spot-film device (fluorescent screen):
Pressure direction: 300mm
Horizontal direction: the center of diagnostic bed moves left(right):±80mm
Vertical direction: 400mm
6.Diagnostic bed:
Ray-filter for fluoroscopy:Manual single blade
Distance between focus and bed face:
At fluoroscopy and gastrointestinal radiography: 400mm(fix)
Ray-filter tube (device) for radiography (fix X-ray field):
Big (rectangle):14"×17"
Middle (rectangle):10"×12" Distance between focus and film=1m
Small (circle):φ5"
Packaging Details: Standard export packing
we will provided the best quality and Lowest Price for you.your products have any problems,could contact us,we will solve as soon as possible
KIT ALEXA brand is famous for all over the world.
Dubai International Exhibition Center
2015 Dubai Arab Health KIT ALEXA ,Booth NO:Z4L50
2016 Dubai Arab Health KIT ALEXA ,Booth NO:PN10