Rapid Disposable Urine KA-TS00028 Drug Test Strip/Cassette
USD $0.4 - $1.2 /Piece
Min.Order:3000 Pieces
Qinhuangdao Kit Alexa Medical Trading Co., Ltd.
Rapid Disposable Urine KA-TS00028 Drug Test Strip/Cassette
1. Application:
Drugs panel Tests include 14 different parameters for urine drug test kit is available , which
is AMP (Amphetamine) / BAR (Barbiturates) / BZO (Benzodiazepines) / COC (Cocaine) / MTD
(Methadone) / MDMA (Ecstasy) / MAMP (Met,Methamphetamine) / MOR
(MOP,Morphine,heroine) / PCP (Phencyclidine) / THC (Marijuana) / TCA (Tricyclic
Antidepressants) / OXY (Oxycodone) / KET (Ketamine) / BUP (Buprenorphine), any
parameter as multi drug test panel is available
B.
FLEXIBILITY
Up to 20 drugs of abuse per test
20 drug assays to choose from
Specimen validity test available
Customized configurations available
Multiple drug combinations
Multiple cut-off options for certain drugs
2. Use ways:
Bring the pouch to room temperature before opening it. Remove the test card from the sealed pouch
and use it as soon as possible. Remove the cap from the end of the test card. With arrows pointing
toward the urine specimen, immerse the strip(s) of the test card vertically in the urine specimen for at
least 10-15 seconds. Immerse the test card to at least the level of the wavy lines on the strip(s), but
not above the arrow(s) on the test card. See the illustration below.
Place the test card on a non-absorbent flat surface, start the timer and wait for the red line(s) to
appear. The results should be read at 5 minutes. Do not interpret results after 10 minutes.
3. Results:
NEGATIVE:* Two lines appear. One red line should be in the control region (C), and another
apparent red or pink line adjacent should be in the test region (T). This negative result indicates that
the drug concentration is below the detectable level.
*NOTE: The shade of red in the test line region (T) will vary, but it should be considered negative
whenever there is even a faint pink line.
POSITIVE: One red line appears in the control region (C). No line appears in the test region (T). This
positive result indicates that the drug concentration is above the detectable level.
INVALID: Control line fails to appear. Insufficient specimen volume or incorrect procedural techniques
are the most likely reasons for control line failure. Review the procedure and repeat the test using a
new test panel. If the problem persists, discontinue using the lot immediately and contact your local
distributor.
Packaging Details: carton
we will provided the best quality and Lowest Price for you.your products have any problems,could contact us,we will solve as soon as possible
KIT ALEXA brand is famous for all over the world.
Dubai International Exhibition Center
2015 Dubai Arab Health KIT ALEXA ,Booth NO:Z4L50
2016 Dubai Arab Health KIT ALEXA ,Booth NO:PN10