KH30R-II benchtop centrfiuge pathology lab equipment
USD $6,763 - $7,625 /Set
Min.Order:1 Set
Hunan Hongda Scientific Instruments Co., Ltd.
centrfiuge lab equipment
KH30R-II benchtop centrfiuge pathology lab equipment
1. Advanced Control System, Excellent separation 1) 10 kinds of Accel/Decel modes can be selected; User can set up the operate parameter by themselves, to achieve the best centrifugal result. 2) Short running function, easy to achieve diversification of centrifugation. 3) Proprietary SCT speed control technical, high efficiency. 4) Proprietary SBT soft brake control technical, to avoid mix up and ensure get maximum specimen. |
2. High Safety, Ease of use 1) Auto-ID instrant rotor identification system, no need to select rotor No. 2) Over temperature, over speed, door and unbalanced protection. 3) Steel body, Stainless steel chamber, Steel Protective sleeve. 4) Can take the rotor with aerosol-tight lid for use with hazardous samples. |
3. Friendly Display, Humanity Operate 1) LCD and LED multiple display, the Programs, Accel/Decel modes, RPM/RCF, Time, and Temperature are all easy to set up. 2. Microprocessor control, can start the instrument with RCF directly, can store and use 40 kinds of self-defining operating modes directly. |
4. Good parts, Reliable and long-lasting 1) Brushless converter motor which has high torque, "SKF" supper speed bearing, Freon-free compressor from Europe. 2) Aerospace rubber for damping, super duralumin alloy from Aluminum Corporation of China Limited (CHALCO). |
5. Universal, multifunctional. Not only take Angle rotor at High Speed, but also Swing rotor at Big capacity & Low Speed, widely used in several kinds of research and production. |
centrifuge for laboratory Rotor Options:
Rotor Type | No. | Capacity | Max Speed (r/min) | Max RCF(×g) | Dimension of tube (mm) |
Angle Rotor | No.1 | 12×1.5ml | 21000 r/min | 30700×g | Φ10×42 |
No.3 | 10×5ml | 18000 r/min | 21010×g | Φ14×54 | |
No.4 | 24×1.5 ml | 17000 r/min | 26630×g | Φ10×42 | |
No.5 | 12×10ml | 16000 r/min | 23820×g | Φ16×81 | |
No.7 | 6×50ml | 14000 r/min | 20150×g | Φ28×105 | |
No.8 | 4×100ml | 14000 r/min | 20000×g | Φ38×124 | |
No.11 | 6×100ml | 10000r/min | 13000×g | Φ38×124 | |
Microplate Rotor | No.13 | 2×2×96 holes | 4000 r/min | 2300×g | Microplate |
Swing Rotor | No.14 | 4×50ml/100ml | 5500 r/min | 5310×g | Φ38×124 |
No.15 | 8×50/100ml | 4000 r/min | 2810×g | Φ38×124 | |
No.16 | 32×10ml/15ml | 4000 r/min | 2810×g | Φ16×85-118 | |
No.17 | 48×5ml | 4000 r/min | 2800×g | Blood collection tube | |
No.20 | 4×250ml | 4000 r/min | 3500×g | Φ64×113 | |
No.21 | 4×500ml | 4000 r/min | 3580×g | Φ80×140 | |
No.22 | 4×750ml | 4000 r/min | 3580×g | Φ99×130 |
skype: lucky.wendy90
Remarks:If you have any question or special requirement about the Medical Large Capacity Refrigerated Centrifuge and its accessories, pls don’t hesitate to contact us. Your request will always draw our first attention. Thanks for all your support!
Product photos :