Specifications
boile, electric steam boile for sale
1.High thermal efficiency> 98%
2.Continuously work 10000 hours
3.Siemens PLC controler
boiler, electric steam boile for sale
Brief Introduction
The LDR series Electrical Heating Steam Feeding Device is a steam-producing device. It is made up of container, control group, water-feeding pump, electrical heating pipe groupware, liquid level controller, relief valve, and etc, and it can control its course automatically. This device turns the water in the container into high-pressure steam by the electrical heating pipe groupware.
Product Feature and Advantage
- High thermal efficiency > 98%.
- our product passed the test of 10000 hours continuously working. Normal standard is 3000 hours.
- Schneider electric control components ensure the stability and good performance.
- Siemens PLC control system with more intelligent function
- Pure cope electric wire and connector.
- 12mm thickness boiler steel container.
- Stainless steel wire drawing cover, beautiful appearance, can be used in hospital, school, and restaurant, Laundry .etc.
Extension Function
- Universalinterfacewith convenient monitoring way:Equip with PROBRS-DP interface and response software, operation and load change data realize centralized monitoring and distance monitoring.
- Boiler network can be built with automatic load change to control the stop and run of many boiler.
- Human-computerinteractiontouch screen: set parameter and supervise operation condition, include alarm and work form change of boiler, is available , supervise item is selectablefor install
Characters
- The container is made of high quality seamless steel tube and armor plate for pressure vessel.
- The electrical heating pipe is made of stainless steel tube. Once destroyed, you can replace it singly.
- Water-feeding pump is able to endure high temperature.
- We use a pressure controller on the device, in order to control the pressure of the steam.
- We also use a liquid level controller, in order to control the level of the water.
- Water feed automatically: When the device is working, the level of the water in the container goes down continuously with steam’s outputting. Until it goes down to the middle level, the water-feeding pump turns on automatically, fills water into the container, till the normal working level (high level) is reached. Then the water-feeding pump will turn off. So the device can provide high-pressure steam by doing this case circularly
Energy Saving
- 42kw (including 42kw)-72kw boilers have two steps, user can put one or both of heating components into operating.
- 72kw (including 72kw)-96kw boilers have three steps, user can put some or all of heating components into operating.
- 96kw (including 96kw)-144kw boilers have four steps, user can put some or all of heating components into operating.
- 144kw (including 144kw) and above boilers have sixsteps, user can put some or all of heating components into operating.
This function will save a lot of electricity when user need not the boiler working at it’s full load.
Steam boiler or generator parameters:
Small type electric heating steam generator: Vertical
Model | Steam Output Kg/h | Rated Power KW | Rated Operating Current A | Electric Cable Parameter | Outline Dimension mm | Weight Kg | Steam outlet Valve Diameter DN | Blown Down Valve Diameter DN | Water Inlet Valve Diameter DN |
LDR0.05-0.7 | 50 | 36 | 55 | 3*25+2(Copper Cable) | 600X1000X1500 | 90 | 25 | 25 | 15 |
LDR0.06-0.7 | 58 | 42 | 64 | 3*25+2(Copper Cable) | 600X1000X1500 | 230 | 25 | 25 | 15 |
LDR0.07-0.7 | 68 | 48 | 73 | 3*25+2(Copper Cable) | 600X1000X1500 | 230 | 25 | 25 | 15 |
LDR0.08-0.7 | 75 | 54 | 82 | 3*35+2(Copper Cable) | 600X1000X1500 | 230 | 25 | 25 | 15 |
LDR0.09-0.7 | 85 | 63 | 95 | 3*35+2(Copper Cable) | 600X1100X1600 | 240 | 25 | 32 | 15 |
LDR0.10-0.7 | 100 | 72 | 109 | 3*35+2(Copper Cable) | 600X1100X1600 | 240 | 25 | 32 | 15 |
LDR0.11-0.7 | 112 | 81 | 123 | 3*50+2(Copper Cable) | 600X1100X1600 | 240 | 25 | 32 | 15 |
LDR0.12-0.7 | 125 | 90 | 136 | 3*50+2(Copper Cable) | 600X1100X1600 | 240 | 2$ | 32 | 15 |
LDR0.13-0.7 | 135 | 96 | 145 | 3*70+2(Copper Cable) | 700X1200X1700 | 360 | 25 | 40 | 25 |
LDR0.15-0.7 | 150 | 108 | 164 | 3*70+2(Copper Cable) | 700X1200X1700 | 360 | 25 | 40 | 25 |
LDR0.17-0.7 | 168 | 120 | 182 | 3*70+2(Copper Cable) | 700X1200X1700 | 380 | 25 | 40 | 25 |
LDR0.20-0.7 | 200 | 144 | 218 | 3*95+2(Copper Cable) | 700X1200X1700 | 380 | 25 | 40 | 25 |