GF302D high precision three phase Electric Meter Testing System
GF302D high precision three phase Electric Meter Testing System
GF302D high precision three phase Electric Meter Testing System
GF302D high precision three phase Electric Meter Testing System
GF302D high precision three phase Electric Meter Testing System
GF302D high precision three phase Electric Meter Testing System

GF302D high precision three phase Electric Meter Testing System

Negotiable /Set

Min.Order:1 Set

Supply Ability:
50 Set / Sets per Month
Port:
Beijing
Payment Terms:
T/T Credit Card

Quick Details View All >

Place of Origin:
Beijing, China
Brand Name:
GFUVE
Model Number:
GF302D
Power:
Electronic
Usage:
Auto Testing Machine

Beijing GFUVE Electronics Co., Ltd.

Business Type: Trading Company
Beijing China
Main Products: Test Equipment ,split core current transformer ,High Voltage Ammeter ,Pos Terminal ,Electrical Measurement Instruments

Product Details

Application of Three phase Kwh Meter testing equipment GF302D high precision Electric Meter Testing System with power source ,CE,ISO9001:2008,IEC approved,english version display,with two years quality warranty.

 

This test equipment is used for grid corporation of measurement and test center, management department of power supply bureau, national energy measurement of testing authorities, and also used to test each kind of single/three phase kWh meter of industries and mining enterprises as well as electric meter manufacturers. Meanwhile, the calibrator also can be used as one high standard power source.

 

Features & Functions

Able to test basic error, shunt running, start, standard error automatically and manually in single-step of single/three phase, according to relative regulation of kWh meter.

     Able to do change test caused by voltage influence, frequency influence and harmonic influence.

Output of power source is speedy and stable, AC maximum output of each phase can reach 100A in maximum.

Voltage, current and phase position of each phase can be adjusted in split-phase, improving the flexibility of power source.

Frequency of each impulse input port can reach 40Hz.

LCD in color and big screen, complete English menu, simple and convenient operation, commonly used functions and current basic load point can be controlled in one button.

Each meter position can provide one standard, dependent RS485 port, and able to do multi-function test such as communication test.

Each meter position can provide six-pulse input port, able to connect active power pulse, reactive power pulse, clock pulse, finishing the whole test process automatically, solving the problems of changing pulse line.

Impulse port of each meter position, external polarity can be set randomly, able to adapt kWh meter of impulse cascade and common-anode.

 

Technical Specification

 

AC Voltage Output & Measurement

Range: 57.7V, 100V, 220V, 380V;

Adjustment range: (0-120)%RG

Adjustment fineness: 0.01%RG, 0.1%RG, 1%RG, 10%RG as optional.

Stability: <0.05%/120s.

Distortion: ≤0.5% (Non-capacitive load);

Output load: each phase 25VA;

Measuring accuracy: 0.05%RG;

(RG means range, the same as below)

AC Current Output & Measurement

Range: 200mA, 1A, 5A, 20A, 100A;

Adjustment range: (0-120)%RG

Adjustment fineness: 0.01%RG, 0.1%RG, 1%RG, 10%RG as optional.

Stability: <0.05%/120s.

Distortion: ≤0.5% (Non-capacitive load);

Output load: 45VA;

Accuracy: 0.05%RG

Power Output & Measurement

Active power output stability: <0.05%RG/120s;

Reactive power output stability: <0.05%RG/120s;

Active power measuring accuracy: 0.05%RG;

Reactive power measuring accuracy: 0.1%RG.

Phase Output & Measurement

Output adjustment range: 0-359.99;

Output adjustment fineness:10, 1, 0.1, 0.01 as optional.

Resolution: 0.001

Measurement accuracy: 0.0005

Frequency Output

Adjustment range: 45Hz-69Hz;

Output adjustment fineness: 5Hz, 1Hz, 0.1Hz, 0.01Hz as optional.

Resolution:0.001Hz;

Accuracy:0.005Hz;

Voltage /Current/Harmonic Setting

Harmonic number:2-31times;

Harmonic content:0-40%;

Harmonic phase:0-359.99;

Harmonic setting accuracy:(10%±0.1%)RD.

RD means the settled harmonic content, harmonic can be a single output, also multiple output.

Power Energy Measurement Error

Active power energy: 0.05%RG;

Reactive power energy: 0.1%RG;

Power Pulse Output

Power pulse type: support active pulse and reactive pulse.

Active power pulse output is 5V, output is 10mA.

Power Pulse Input

Energy pulse type: support active and reactive pulse, the highest frequency power pulse input is 180K.

Dimension

500mmx600mmx175mm;

Weight: About 27KG;

Power Supply: One Phase AC 180~265V , frequency 50/60Hz;

 GF302D high precision three phase Electric Meter Testing SystemGF302D high precision three phase Electric Meter Testing SystemGF302D high precision three phase Electric Meter Testing SystemGF302D high precision three phase Electric Meter Testing SystemGF302D high precision three phase Electric Meter Testing SystemGF302D high precision three phase Electric Meter Testing System

 

Certifications

GF302D high precision three phase Electric Meter Testing System

 

Contact Supplier

Mr. Andy Huang manager Chat Now
Telephone
86-10-85782698
Mobile
18901232181
Fax
86-10-85781298
Address
Bldg. 1-1006, Joy Mansion, No. 99 Chaoyang North Road, Chaoyang District, Beijing, China Beijing

You May Like

New Products

Recommended Products

View More View Less

Find Similar Products By Category

Measurement & Analysis Instruments > Testing Equipment
Categories
Hi~