Copper Cable Yjv 26/35kv 1x400 33kv Xlpe Armoured Cable
USD $1 - $50 /Kilometer
Min.Order:1 Kilometer
Henan Sanheng Industrial Co., Ltd.
Copper Cable Yjv 26/35kv 1x400 33kv Xlpe Armoured Cable
1 Description
Construction: Compacted stranded circular copper conductor, extruded semi-conducting compound as conductor screen, cross-linked polyethylene(XLPE) insulation, semi-conducting compound as insulation screen, copper tape or combination of copper wire and tape as metallic screen, three cores assembled together with non-hygroscopic polypropylene filler, wrapped with binder tape, PVC or PE outer sheath.
2 Application
The cable is used for fixed installations such as electric power distribution networks or industrial installations, which is laid indoors, outdoors, in tunnel or in cable trench, unable to bear external mechanical force.
Single core cable in magnetic duct is not permissible.
3 Operating Characteristics
Rated voltage U0/U(Um):19/33(36)kV
U0 is the rated power frequency voltage between conductor and earth or metallic screen for which the cable is designed;
U is the rated power frequency voltage between conductors for which the cableis designed;
Um is the maximum value of the "highest system voltage" for which the equipment may be used.
Max. permissible continuous operating temperature of conductor: 90 °C
Max. temperature of conductor during short-circuit (5s max. duration) shall not exceed: 250 °C
The ambient temperature under installation should not be lower than: 0 °C
The bending radius of cable is recommended as following:
For single core cable: not less than 20 times of the diameter of cable
For three core cable: not less than 15 times of the diameter of cable
4 Manufacturing Standards
GB/T 12706-2008, IEC 60502-2
Type | Description | Number of cores | Nominal cross section of conductor (mm2) | ||||
3.6/6kV | 6/10kV 6.35/11kV | 8.7/15kV | 12/20kV 12.7/22kV | 18/30kV 19/33kV 25/36kV | |||
YJV22 | CU/XLPE/STA/PVC | 1, 3 | 10~1000 | 16~1000 | 25~1000 | 35~1000 | 50~1000 |
YJLV22 | AL/XLPE/STA/PVC | ||||||
YJSV22 | CU/XLPE/CWS/STA/PVC | 1, 3 | 10~1000 | 16~1000 | 25~1000 | 35~1000 | 50~1000 |
YJLSV22 | AL/XLPE/CWS/STA/PVC | ||||||
YJV62 | CU/XLPE/Non-magnetic STA/PVC | 1 | 10~1000 | 16~1000 | 25~1000 | 35~1000 | 50~1000 |
YJLV62 | AL/XLPE/Non-magnetic STA/PVC | ||||||
YJY23 | CU/XLPE/STA/PE | 1, 3 | 10~1000 | 16~1000 | 25~1000 | 35~1000 | 50~1000 |
YJLY23 | AL/XLPE/STA/PE | ||||||
Z-YJV22 | CU/XLPE/STA Flame-retardant | 1, 3 | 10~1000 | 16~1000 | 25~1000 | 35~1000 | 50~1000 |
Z-YJLV22 | AL/XLPE/STA Flame-retardant | ||||||
WDZ-YJY23 | CU/XLPE/STA/LSHF(or LSZH) Flame-retardant | 1, 3 | 10~1000 | 16~1000 | 25~1000 | 35~1000 | 50~1000 |
WDZ-YJLY23 | AL/XLPE/STA/LSHF (or LSZH) Flame-retardant | ||||||
N-YJV22 | CU/XLPE/STA Fire-resistant | 1, 3 | 10~1000 | 16~1000 | 25~1000 | 35~1000 | 50~1000 |