550x sokkia total station set
Offering more red - tech ii edm, easy - to - operate keypad, powerful onboard software and market - proven reliability, series50rx sets a new standard for reflectorless total stations for all surveying and applications engineering.
durable environment
The series50rx total stations provide industry & and rsquo, s highest durability that withstands the harshest of climates and hardest work site conditions.
High temperature models
It works reliably in the heat of up to +60 deg & c (& +140 deg f) compromizing without low temprature range - 20 & deg c (- 4 & deg f).
Low temperature models
Ensures operations in freezing climates as low as - 30 & deg c (- 22 & deg f) while maintaining high temperature range up to +50 deg c (+122 & deg f).
Meets the highest in its class IP66 dust and water protection.
Enhanced red - tech ii edm
Enhanced red - tech ii edm features extremely fast measurement time and wide reflectorless measurement range of 30cm to 400m.
The series50rx measures distance within 4.2 seconds without a reflector to minimize the variation of the measurement time due to cooking object types and 30 percent, compared with the original red - tech ii edm .
Narrow visible laser beam is also used as a laser pointer; edm measures precisely the point indicates laser spot.
The Series50X & ndash; ultimate sokkia standard.
1. output level laser automatically turns to class 1 specifications & & ldquo; prism & & rdquo, and & and ldquo; reflection sheet & and rdquo; modes to ensure safety.
Two. and sokkia & rsquo, s advanced absolute encoders and digital processing technologies have given a capacity series50rx automatically detect and correct misreading of encoder patterns.
Three. The 2 "model incorporates IACS (angle independent calibration of the system) to further enhance the reliability of measurement.
April. Fully customizable backlit alphanumeric keys and programmable keys allow quick operation at any lighting condition.
May. an optional wireless keyboard SF14 maximizes the efficiency of the operation (except 6 "model).
June. Powerful onboard software.
July. in addition to the 10,000 - point of internal memory, the data can be stored on sd / sdhc cards and USB memory devices.
August. password protection to prevent unauthorized use.
9. green / red light guide is built into the telescope as a standard feature, improved fit - out work efficiency in a range of 1.3 to 150m.
10. Internal Bluetooth ® module (option) is available for wireless connection with a data collector.
1 1. built - in laser plummet for quick instrument setting (factory option).
January 2. optional large external ni-mh batteries are available for 2 "model and under all temperature models.
Series50X total stations |
model | set250x | set350x | set550x | set650x |
Measuring range | With reflective sheet target * | RS90N-K: 1.3 to 150m (4.3 to 490ft.) Rs50n-k: 1.3 to 60m (4.3 to 190ft.) Rs10n-k: 1.3 to 25m (4.3 to 82ft.) |
(Average conditions) | with p 1 prism | A 1.3 3,500 m (4.3 to 11,480 ft.), At 4,000 m (13,120 ft.) Under good conditions |
distance accuracy | With reflective sheet target * | (3 + 2 ppm & times, d) mm |
(ISO17123 - 4:2001) | with the prism | (2 + 2 ppm & times, d) mm |
angle precision | H & v | 2 "/ 0.6 mgon | 3 "/ 1mgon | 5 "/ 1.5 mgon | 6 "/ 1.9 mgon |
(ISO17123 - 3:2001) |
Display resolutions (selectable) | 1 "/ 5", 0.0002/0.001 gon, 0.005/0.02 thousand |
Data storage | internal memory | Approx. 10,000 points |
Plug - in a memory device | Sdhc sd card and card (max 4GB) |
Usb flash memory (max. 4GB) |
interface | RS-232C serial |
bluetooth wireless communication | The option (VERSION. 1. 2 class 2) |
wireless keyboard | Option (SF14 wireless keyboard with infrared communication) | & Less; |
dust and water protection | Ip66 (iec 60529:2001) |
Weight with handle and battery | 5.5kg (12.1 lbs.) | 5.4kg (11.9 lbs.) | 5.3kg (11.7 lbs.) |