Water to air monobloc unit -DC inverter heat pump

Water to air monobloc unit -DC inverter heat pump

Negotiable /Set

Min.Order:1 Set

Supply Ability:
300 Set / Sets per Month
Port:
Guangzhou
Payment Terms:
T/T

Quick Details View All >

Type:
Flat-Plate
Pressure:
Unpressurized
Circulation Type:
Direct / Open Loop (Active)
Heating System:
Thermosyphon (Passive)
Connection Type:
Direct-Plug
Installation:
Freestanding

GZ Axen Heating Technologies Limited

Business Type: Manufacturer
Guangzhou Guangdong China
Main Products: Air Source Heat Pump ,Hot Water Heat Pump ,Swimming Pool Heat Pump

Product Details

Specifications

Axen DC Inverter Water to Air Monobloc Unit utilizes free renewable energy from ground.

Products Information

Axen DC Inverter Water to Air Monobloc Unit utilizes free renewable energy from ground. The units are highly efficient with low running costs, low carbon emission. Thanks for the advanced DC inverter technology adopted, the units are with higher efficiency and save great amount of energy. The units provide independent cool or heat air to home. As each unit is independent, user can select cooling or heating mode as their wishes. Compared to the traditional central air conditioning system, it is more flexible and energy saving.

Product features:
1. Super high efficient, its COP reaches 5.0.
2. Super thin design, the unit needs smaller installation space.
3. Easy installation and easy maintenance.
4. Electric expansion valve keeps the most suitable refrigerant flow in any case.
5. Full protection functions keep the system safe, such as water flow protection, high/low pressure protection, overheating, etc.
6. Microprocessor control, self diagnosis and error alarm.
7. Green gas R410A.
 

Specification- Water to Air Monobloc Unit-DC Inverter

TECHNICAL DATA

AXWAI-03HA

AXWAI-04HA

AXWAI-07HA

AXWAI-10HA

AXWAI-15HA

AXWAI-20HA/3

Heating

Nominal capacity

kW

3.0(1.2-3.2)

4.0(2.4-4.5)

7.0(3.6-7.6)

10.0(5.1-11.2)

15.0(7.1-17.2)

20.0(9.2-22.3)

Power input

kW

0.62(0.32-0.75)

0.93(0.45-1.18)

1.45(0.62-1.72)

2.16(0.89-2.63)

3.18(1.30-3.68)

4.23(1.80-4.53)

COP

W/W

4.84

4.32

4.83

4.62

4.72

4.73

Cooling

Nominal capacity

kW

2.5(1.0-3.0)

3.3(2.0-4.0)

5.8(3.0-7.0)

7.5(4.0-8.7)

11.2(5.4-14.0)

15.0(7.2-17.0)

Power input

kW

0.65(0.32-0.70)

0.95(0.48-1.28)

1.5(0.62-1.70)

1.90(0.87-2.65)

2.93(1.30-3.60)

3.86(1.75-4.43)

EER

W/W

3.86

3.48

3.87

3.95

3.82

3.89

Power supply

V/Ph/Hz

220-240/1/50

380-415/3/50

Compressor

Rotary(DC Inverter)

Refrigerant

R410A

Water Source Side

Heat-exchanger
type

 

High Efficient Shell & Tube Heat Exchanger

Flow volume

m³/h

0.45

0.45

1.16

1.67

2.5

3.4

Pressure loss

kpa

9

9

9

9

9

9

Water tube joint

inch

1

1

1

1

1.5

1.5

User Side

Heat-exchanger
type

 

Fin Tube heat exchanger

Flow volume

m³/h

500

560

1000

1500

1800

2200

Dimension (Net)

HxWxD

mm

351x854x515

351x854x515

554x1134x590

554x1134x590

700x1500x700

700x1500x700

Dimension (Packing)

HxWxD

mm

450x950x600

450x950x600

650x1230x690

650x1230x690

800x1600x800

800x1600x800

Net weight

kg

75

75

125

125

160

185

Gross weight

kg

85

85

135

135

175

200

Noise level

dB(A)

50

50

51

56

58

60

NOTES: 
Capacities and power inputs based on thefollowing conditions: 
Cooling: Water Inlet/Outlet temperature 30°C/35°C, entering air temperature 27°C DB, 19°C WB.
Heating: Water Inlet temperature 20°C, entering air temperature 20°C DB, 15°C WB. The flow rate.
obtained during the test at standard rating conditions in cooling mode is used.

 

 

Products Information

Axen DC Inverter Water to Air Monobloc Unit utilizes free renewable energy from ground. The units are highly efficient with low running costs, low carbon emission. Thanks for the advanced DC inverter technology adopted, the units are with higher efficiency and save great amount of energy. The units provide independent cool or heat air to home. As each unit is independent, user can select cooling or heating mode as their wishes. Compared to the traditional central air conditioning system, it is more flexible and energy saving.

Product features:
1. Super high efficient, its COP reaches 5.0.
2. Super thin design, the unit needs smaller installation space.
3. Easy installation and easy maintenance.
4. Electric expansion valve keeps the most suitable refrigerant flow in any case.
5. Full protection functions keep the system safe, such as water flow protection, high/low pressure protection, overheating, etc.
6. Microprocessor control, self diagnosis and error alarm.
7. Green gas R410A.
 

Specification- Water to Air Monobloc Unit-DC Inverter

TECHNICAL DATA

AXWAI-03HA

AXWAI-04HA

AXWAI-07HA

AXWAI-10HA

AXWAI-15HA

AXWAI-20HA/3

Heating

Nominal capacity

kW

3.0(1.2-3.2)

4.0(2.4-4.5)

7.0(3.6-7.6)

10.0(5.1-11.2)

15.0(7.1-17.2)

20.0(9.2-22.3)

Power input

kW

0.62(0.32-0.75)

0.93(0.45-1.18)

1.45(0.62-1.72)

2.16(0.89-2.63)

3.18(1.30-3.68)

4.23(1.80-4.53)

COP

W/W

4.84

4.32

4.83

4.62

4.72

4.73

Cooling

Nominal capacity

kW

2.5(1.0-3.0)

3.3(2.0-4.0)

5.8(3.0-7.0)

7.5(4.0-8.7)

11.2(5.4-14.0)

15.0(7.2-17.0)

Power input

kW

0.65(0.32-0.70)

0.95(0.48-1.28)

1.5(0.62-1.70)

1.90(0.87-2.65)

2.93(1.30-3.60)

3.86(1.75-4.43)

EER

W/W

3.86

3.48

3.87

3.95

3.82

3.89

Power supply

V/Ph/Hz

220-240/1/50

380-415/3/50

Compressor

Rotary(DC Inverter)

Refrigerant

R410A

Water Source Side

Heat-exchanger
type

 

High Efficient Shell & Tube Heat Exchanger

Flow volume

m³/h

0.45

0.45

1.16

1.67

2.5

3.4

Pressure loss

kpa

9

9

9

9

9

9

Water tube joint

inch

1

1

1

1

1.5

1.5

User Side

Heat-exchanger
type

 

Fin Tube heat exchanger

Flow volume

m³/h

500

560

1000

1500

1800

2200

Dimension (Net)

HxWxD

mm

351x854x515

351x854x515

554x1134x590

554x1134x590

700x1500x700

700x1500x700

Dimension (Packing)

HxWxD

mm

450x950x600

450x950x600

650x1230x690

650x1230x690

800x1600x800

800x1600x800

Net weight

kg

75

75

125

125

160

185

Gross weight

kg

85

85

135

135

175

200

Noise level

dB(A)

50

50

51

56

58

60

NOTES: 
Capacities and power inputs based on thefollowing conditions: 
Cooling: Water Inlet/Outlet temperature 30°C/35°C, entering air temperature 27°C DB, 19°C WB.
Heating: Water Inlet temperature 20°C, entering air temperature 20°C DB, 15°C WB. The flow rate.
obtained during the test at standard rating conditions in cooling mode is used.

 

Contact Supplier

Mr. Dabin Dai Sales Director Chat Now
Telephone
86-20-23883501
Mobile
0086 13726394440
Fax
86-20-39114068
Address
No.23 Huachuang Animation Industrial Park, Shiji Town, Panyu, Guangzhou,China Guangzhou,Guangdong

You May Like

New Products

Recommended Products

View More View Less

Find Similar Products By Category

Home Appliances > Water Heaters > Solar Water Heaters
Categories
Hi~