three phase electric 18kw-1600kw generator
USD $4,500 - $330,000 /Set
Min.Order:1 Set
Shandong Supermaly Generating Equipment Co., Ltd.
18kw-1600kw mobile diesel generator sets with high quality
Portable Diesel Generator
Detailed Product Description of portable diesel generator:
1) portable generator manufactured by famous factories.
2) portable generator match the world famous alternators.
3) pertable generator strict tests before sale.
4) portable generator features at low oil consumption, stable performance, easy maintenance, low operation cost, low emission.
The specification of engine of portable diesel generator:
1)Original high quality engines
2) Small volume, light weight, low noise, low fuel consumption,
3) Water-cooling with water tank and fan
4) Maintain easily, low maintenance expense
Model | 403D-11G,404D-22G,1103A-33G,1104C-44TAG1,1106C-E66TAG4,2306C-E14TAG1,2806A-E18TAG1A |
Cooling Method | water cooled |
Rotating speed | 1500/1800rpm |
Governor system | electrical or mechanical governor |
Aspiration mode | natural aspirated or turbocharged |
Starting method | 12/24V DC electric starting |
Stroke | 4 stroke |
The specification of alternator of portable diesel generator:
Brand | Stamford, Leroy semor, Maraton etc. |
Regulator | AVR automatic voltage regulating |
Excite type | pret or shunt |
Connecting type | 3PH star, 3PH-DELTA |
Steady frequency change | 0-5% |
No load voltage | ≥95%-105 |
Steady voltage | ≤±1 |
Insulation degree | H degree |
Exclosure degree | IP23 |
portable generator use of safety norms
1.Operators sould be familiar with the operation of generating units, operating methods, and all control bodies, manual valves, stopping body position.
2.In the engine room or near the unit, must hoisting of danger notices warning signs associated personnel:
(1)Uints exist electric shocks danger;
(2)Uints exist scald danger;
(3)Units exist winding, and collision dangers;
3.To avoid fuel, lubricants, and other fire, engine room No smoking.
4.Engine room or other nearest shouldmaintain an appropriate level of fire service equipment (proposed CO2 fire extinguishers).
5.Grounding the entire unit reliably, and meet the applicable requirements of neutral grounding.
6.Above and around the unit should not be unrelated equipment, obstructions and dangerous goods, should be keeping the floor dry and clean without oil.
7.Units will be run by noise, suggest that the staff wear suitable protective equipment, such as earmuffs vehicles.
8.Before any maintenance, must cut off all power lines, particularly the Dcpower supply circuit (remove the battery’s anode and cathode), the warning signs must also note “is maintenance“, and should have another concern, especially in the narrow region maintenance at the same time should be nitified stop all of this unit operation.
9.To the reliable operation of unit, the settings of unit voltage, frequency, speed and other related parameters and unit controller set up should not be arbitrarily changed except the specialized operators.
10.Units are valuable equipment, for personal safety, operation stability to light, no illegal operation and drink operation.
if you have any question, please feel free to contact with me:
Miss Dan Tang
Company Name: Weifang Supermaly generating Equipment Co , . Ltd
Tel&Fax: 0086-0536-2118175
Mobile Tel: 0086-18463651770
QQ: 2048739366
Email: tangdan @supermaly.com
Website: