hotel access control door lock system LSD8098
USD $20 - $50 /Piece
Min.Order:50 Pieces
Shenzhen Tong Chuang Xin Jia Technology Co., Ltd.
Start Hotel Door Lock Start Hotel Door Lock Start Hotel Door Lock Start Hotel Door Lock Start Hotel Door Lock
Hotel access control door lock system:
Technical Parameters:
Model No. | LSD-8098-RF |
Lock type | The durable and convenient Electronic door Lock |
Lock open solution | RF Card, Mechanical key |
International Standard | ISO14443-A,ISO11784/785 |
Battery | 4 pieces AA alkaline battery (6V) |
Low voltage alarm | 4.8V(6V power supply) |
Static current | 20~50uA. |
Dynamic current | 70mA. |
Working temperature | -20°C~55°C |
Storage temperature | -30°C~70°C |
Working humidity | 15%RH~93%RF |
Average working time of trouble-free | ≥25,000h |
Cylinder | Hidden cylinder, mechanical key override |
Mortise | ANSI standard mortise |
Mortise size | 257.3x112.4x28.6mm |
Lock Panel size | 287x73mm |
Material | Stainless steel |
Package | 1 piece per box, 6 pieces per carton |
Color | PVD gold, silver
|
Hotel Access Control Door Lock System Composition:
Cards Functions
Cards | Function |
1. Authorization card 2. Clock card 3. Room setting card | These are functions cards for setting the door lock. All new locks must be set by these 3 cards first after installed on the door. |
4. Guest card | To open certain guest room, with the time and double locked limit, it's hold by the guest. |
5. Master card | To open all the doors in one hotel, no limited on deadbolt and time. Kept by the general manager. |
6. Building card | To open all the doors in a certain building, limited on deadbolt and time. Kept by the manager. |
7. Floor card | To open all the doors in a certain floor ,limited on deadbolt and time. Kept by foremen. |
8. Clean up card | To open the locks of the assigned zone, with double-locked and time limit. Kept by house keeper. Before issing clean-up card, have to set up clean up zone first. |
9. Emergency card | To open doors with no limits, even when the door is double locked. It can keep lock on long-time unlocking state.Usually General Manager / hotel guard hold this card in case of situation like fire etc. |
10. Stop card | To stop the function of the guest card |
11. Seal card | To seal the unused rooms. Hold by room Manager. Only Emergency card can open the lock once sealed. |
12. Alarm card | To set door ajar funtion, when the lock is not locked well, it will alarm to remind the clients. |
13. Don't interrupt card | To set don’t interrupt function in the condition of deadbolt |
14. Normally open card | To set the lock in the unlocking state. |
15. Check out card | To stop the function of guest room card when guest would like to check out ahead of schedule or the guest room card lost. |