double flange mounted differential level transmitter
USD $100 - $800 /Piece
Min.Order:1 Piece
Xi'an Yunyi Instrument Co., Ltd.
double flange mounted differential level transmitter
Technical data double flange mounted differential level transmitter :
1Output:
Analog : Two-wire 4 ~ 20mADC
Digital: two-wire 4 ~ 20mADC and superimposed HART protocol process variable digital signals.
2 Power: 12.5 ~ 45VDC supply voltage
3 Load Limit: Maximum load resistance Rmax loop depends on the supply voltage . HART Communication requires a load resistance of not less than 250Ω, not more than 600Ω
4 Communication distance: maximum communication distance of 1.5Km, multi- station communication can connect up to 15 units of smart transmitters .
5 Output Display: four digital display system , five LCD display, pointer .
6 Proof in the form :
Intrinsically Safe : ExiaII CT5
Flameproof
7 Zero migration range: zero can easily migrate positive or negative migration, but not so set on the lower measuring range and range beyond the limit.
8 Temperature range: Ambient temperature : -40 ~ 85 °C ( optional LCD instruction table is -20 ~ 70 °C)
9 Measuring medium temperature : -40 ~ 104 °C
10 Remote device fill fluid ( temperature ) :
Visco : -29 ~ +149 °C
Inert oil : -18 ~ +204 °C
11Pressure limits:
Threaded : 3.45Kpa ( absolute pressure ) ~ 13.78MPa
Flanged : 3.45Kpa ( absolute pressure ) Flange Pressure Rating
Plug-in : 3.45Kpa ( absolute pressure ) Flange Pressure Rating
Flat : 3.45Kpa ( absolute pressure ) Flange Pressure Rating
12 Relative humidity : 5 ~ 98% RH
13 Start-up time : Within 5 seconds to start
14 Capacity variation : less than 0.16cm3
15 Damping adjustment: time from 0.20 to 25 seconds type
Performance indicators:
Under no migration , capillary length 1.53m filling oil, 316 stainless steel diaphragm conditions : reference conditions
Temperature effects: remote device ( typically ) one side ( capillary remote 1.53m table remote device )
Flat : error of less than 0.62Kpa/55 °C, using silicone capillary filling each additional 1.53 m error increases 0.20Kpa
Threaded and flange type : error of less than 1.99Kpa/55 °C, using silicone capillary filling error increases for each additional 1.53 m 0.62 Kpa
Vibration: can withstand any axial vibration frequencies up to 200Hz , the error is ± 0.05% URL
Power effect: less than 0.005% of the tone scale / V
Load Impact: No load impact
Mounting Position Effect : 250Pa roughly zero migration , which can be calibrated , no scale effect .
RF interference effect: at a frequency of 30-1000MHz and maximum field strength 10V / m conditions caused by the drift of ± 0.1% of span adjustment
About Us:
Xi'an Yunyi Instrument Co., Ltd. is a professional manufacturer that engaged in the fields of pressure measurement instrument, the chief engineer Mr Tian has more than 30 years on this area, he is one of the engineers who introduced the Rosemount technology. We specializing in developing high precision pressure transmitter and pressure gauges. And we also develop temperature transmitter, level transmitter, densitometer etc. They are widely used in chemical, petroleum, paper, electricity, city gas, environmental protection, water treatment and other fields.
If you need this Double flange differential pressure transmitter , please visit the website