pressure testing equipment Eja115a
USD $450 - $850 /Piece
Min.Order:1 Piece
Xi'an Yunyi Instrument Co., Ltd.
pressure testing equipment Eja115a
Descrition of pressure testing equipment Eja115a :
1.The model EJA115 Low Flow Transmitter is a differential pressure transmitter assembled with an integral orifice and excellent for very low flow measurement. It outputs a 4 to 20 mA DC signal corresponding to the measured flow.
2.The orifice is available in six types with a bore ranging from 0.508 mm to 6.350 mm. The combination of the bore selection with the differential pressure measurement span variation of the differential pressure transmitter enables a wide range of very small flow measurement.
Specifications of Yokogawa Eja115a transmitter:
| EJA115 Low Flow Transmitter | |||
L Capsule | M Capsule | H Capsule | ||
Water equivalent | 0.016 to 7.2 l/min | 0.022 to 23 l/min | 0.07 to 33 l/min | |
Air equivalent flow | 0.44 to 198 Nl/min | 0.63 to 635 Nl/min | 2 to 910 Nl/min | |
Differential pressure span | 1 to 10 kPa | 2 to 100 kPa | 20 to 210 kPa | |
Accuracy | ±5% | ±5% | ±5% | |
Degrees of protection | IP67, NEMA 4X, and JIS C0920 immersion proof | |||
Certificates | FM, CENELEC ATEX, CSA, TIIS, IECEx | |||
Output | 4 to 20 mA DC or FOUNDATION™ fieldbus or PROFIBUS PA 2-wire system with digital communication | |||
Supply voltage | BRAIN and HART:10.5 to 42 V DC (10.5 to 30 V DC for Intrinsically safe type) | |||
Ambient temperature | -40 to 85 deg C (-40 to 185 deg F) (general use type) | |||
Process temperature | -40 to 120 deg C (-40 to 248 deg F) (general use type) | |||
Maximum working pressure | 3.5 MPa | 14 MPa | ||
Mounting | 2-inch pipe mounting | |||
Wetted parts material | Capsule | SUS316L(Diaphragm material is Hastelloy C-276) | ||
Manifold | SUS316 | |||
Cover flange | SUS316 | |||
Housing | Cast aluminum alloy or SUS316 equivalent stainless steel (optional) |
MODEL AND SUFFIX CODES of pressure testing equipment Eja115a
Model | Optional codes | Description |
EJA115 | ······ | <p >Low Flow transmitter |
Output Signal | -D . . . . . . . | 4 to20mA DC with digital communication(BRAIN protocol) 4to20mA DC with digital communication(HART protocol)*1 Digital communication (FOUNDATION Fieldbusprotocol)*6 Digital communication (PROFIBUSPA protocol)*9 |
Measuremen span(capsule) | L . . . . . . . M . . . . . . . H . . . . . . . | 1 to 10kPa {100 to 1000 mmH2O}{4 to 40 inH2O}{10 to 100 mbar} 2 to 100kPa {200 to 10000 mmH2O}{8 to400 inH2O}{20 to1000 mbar} 20 to 210kPa {2000 to 21000 mmH2O}{80 to830 inH2O}{200 to2100 mbar} |
Wettedparts material*8 |
S*. . . . . . . | [Body] [Capsule] [Orifice] JISSCS14A*3 JISSUS316L*2 JISSUS316 |
Process flange rating | 2 . . . . . . . | Rc1/2 female 1/2NPT female |
- | 00 . . . . . . | Always00 |
Bolts and nuts material |
A . . . . . . . B . . . . . . . | [Maximum working pressure] (Lcapsule) (M,Hcapsule) JISSCM435 3.5MPa{35kgf/cm2} 14MPa{140kgf/cm2} JISSUS630 3.5MPa{35kgf/cm2} 14MPa{140kgf/cm2} |
Installation | -2 . . . . . . -9 . . . . . . | Vertical impulse piping type, right side high pressure, manifold upside *4 Vertical impulse piping type, right side high pressure, manifold downside *4 Vertical impulse piping type, left side high pressure, manifold upside *4 Vertical impulse piping type, left side high pressure, manifold downside *4 Horizontal impulse piping type, right side high pressure *5 Horizontal impulse piping type, left side high pressure *5 |
Electrical connection | 0 . . . . . . . 2 . . . . . . . 3 . . . . . . . 4 . . . . . . . 5 . . . . . . . 7 . . . . . . . 8 . . . . . . . 9 . . . . . . . A . . . . . . . C . . . . . . . D . . . . . . . | G1/2 female,one electrical connection 1/2 NPT female, two electrical connections without blind plug Pg 13.5 female, two electrical connections without blind plug M20 female, two electrical connections without blind plug G1/2 female, two electrical connections and a blind plug 1/2 NPT female, two electrical connections and a blind plug Pg 13.5 female, two electrical connections and a blind plug M20 female, two electrical connections and a blind plug G1/2 female, two electrical connections and a SUS316 blind plug 1/2 NPT female, two electrical connections and a SUS316 blind plug M20 female, two electrical connections and a SUS316 blind plug |
Integralindicator | D . . . . . . E . . . . . . N . . . . . . | Digitalindicator Digitalindicator with the range setting switch *7 (None) |
Mounting bracket | A . . . . . . K . . . . . . | JIS SECC 2-inch pipe mounting(flat type) JIS SUS304 2-inch pipe mounting(flat type) JIS SUS316 2-inch pipe mounting(flat type) JIS SECC 2-inch pipe mounting(L type) JIS SUS304 2-inch pipe mounting(L type) JIS SUS316 2-inch pipe mounting (L type) (None) |
Optional codes | /◊Optional specification |
If you need this Yokogawa differential pressure transmitter ejx110a ,please visit the websit