Capacitance liquid level transmitter
USD $307.00 - $307.00 /Piece
Min.Order:20 Pieces
Xi'an Yunyi Instrument Co., Ltd.
Capacitance liquid level transmitter
Technical data of Capacitance liquid level transmitter:
1Output: Analog : Two-wire 4 ~ 20mADC/Digital: two-wire 4 ~ 20mADC and superimposed HART protocol process variable digital signals.
2 Power: 12.5 ~ 45VDC supply voltage
3 Load Limit: Maximum load resistance Rmax loop depends on the supply voltage . HART Communication requires a load resistance of not less than 250Ω, not more than 600Ω
4 Communication distance: maximum communication distance of 1.5Km, multi- station communication can connect up to 15 units of smart transmitters .
5 Output Display: four digital display system , five LCD display, pointer .
6 Proof in the form : Intrinsically Safe : ExiaII CT / Flameproof
7 Zero migration range: zero can easily migrate positive or negative migration, but not so set on the lower measuring range and range beyond the limit.
8 Temperature range: Ambient temperature : -40 ~ 85 °C ( optional LCD instruction table is -20 ~ 70 °C)
9 Measuring medium temperature : -40 ~ 104 °C
10 Remote device fill fluid ( temperature ) :
Visco : -29 ~ +149 °C
Inert oil : -18 ~ +204 °C
11Pressure limits:
Threaded : 3.45Kpa ( absolute pressure ) ~ 13.78MPa
Flanged : 3.45Kpa ( absolute pressure ) Flange Pressure Rating
Plug-in : 3.45Kpa ( absolute pressure ) Flange Pressure Rating
Flat : 3.45Kpa ( absolute pressure ) Flange Pressure Rating
12 Relative humidity : 5 ~ 98% RH
13 Start-up time : Within 5 seconds to start
14 Capacity variation : less than 0.16cm3
15 Damping adjustment: time from 0.20 to 25 seconds type
Performance indicators of Capacitance liquid level transmitter:
Under no migration , capillary length 1.53m filling oil, 316 stainless steel diaphragm conditions : reference conditions
Temperature effects: remote device ( typically ) one side ( capillary remote 1.53m table remote device )
Flat : error of less than 0.62Kpa/55 °C, using silicone capillary filling each additional 1.53 m error increases 0.20Kpa
Threaded and flange type : error of less than 1.99Kpa/55 °C, using silicone capillary filling error increases for each additional 1.53 m 0.62 Kpa
Vibration: can withstand any axial vibration frequencies up to 200Hz , the error is ± 0.05% URL
Power effect: less than 0.005% of the tone scale / V
Load Impact: No load impact
Mounting Position Effect : 250Pa roughly zero migration , which can be calibrated , no scale effect .
RF interference effect: at a frequency of 30-1000MHz and maximum field strength 10V / m conditions caused by the drift of ± 0.1% of span adjustment