GH-300 Tank Calibration System, accurate gasoline tank calibration, standard tank gauge system
USD $10,000 - $20,000 /Piece
Min.Order:1 Piece
Qingdao Guihe Measurement & Control Technology Co., Ltd.
GH-300 Tank Calibration System, accurate gasoline tank calibration, standard tank gauge system
GH-300 Tank Volume Table Calibration System
It’s necessary to calibrate the tank volume table
The nonstandard manufacturing, tilted installation of the tank will easy to cause the volume table inaccurate. This means a loss to the gas station.
Operational principle
This system consists of Tank Volume Table Calibration Instrument, Liquid Level Meter, Special Software and computer.
Fill the tank up, pump out the product to another tank or tanker though the Tank Volume Table Calibration Instrument, the product volume would be calculated automatically and the data would be uploaded to computer. Meanwhile, the data of product level collected by Liquid Level Meter uploaded to computer as well. According to the data uploaded, the Special Software will do analyze and process, and finally generate an accurate electronic volume table.
Characteristic
Need not manual operate whole processing, generate the volume table automatically.
This system can operate individually whether there is a computer.
It’s easy to use the software.
It’s convenient to move with compact design.
The fuel pump will never pumpdown as the system can setup a lowest product level limit.
The volume table is accurate as its error rate is 3‰~5‰
With fast operate speed , it’s less than 2.5 hours to measure a tank with 30m³
It features a protection function to avoid the data losing.
Users can import directly the volume table generated by this system into the Word or Excel.
Performance
Item | GH-300 Tank Volume Table Calibration System |
Purpose | Tank Volume Table Calibration |
Medium | Gasoline, diesel, kerosene, ethanol etc. |
State of medium | Liquid |
Explosion-proof grade | DIIBT4 |
Pressure range | -0.02Mpa~0.6 Mpa |
Certificate | PCEC Conformity Certificate of Explosion-proof / Permit of Manufacture Measuring Instruments |
Temperature | -40℃~70℃ |
Volume Accuracy | 3‰~5‰ |
Product Level Accuracy | ±0.2mm |
Temperature Accuracy | ±0.2℃ |
Height Resolution | 0.01mm |
Repeatability | ±0.1mm |
Environmental Temperature Effect | Error<0.2mm |
Vibration Effect | Error<0.5mm |
Lowest Product Inactive Zone | 2.5'' floater-120mm |
Measuring Range | 10~30m³ |
Method of Communication | RS-485 |
Measuring Time | Less than 2.5 hours measuring one tank with 30m |
Power Supply | AC380V 50HZ |
Protection Class of Case | IP54 |