MODEL | 200w-5v-40A | |||||
OUTPUT | DC VOLTAGE | 5V | ||||
OUTPUT POWER | 200W | |||||
CURRENT RANGE | 0-40A | |||||
RIPPLE & NOISE(max.) | 50mVp-p | |||||
VOLTAGE ADJ. RANGE | ±10% | |||||
LINE REGULATION | ±0.5% | |||||
LOAD REGULATION | ±2.0% | |||||
VOLTAGE TOLERANCE | ||||||
CONNECTION TERMINAL | MARK: GND , DC+ | |||||
SETUP,RISE TIME | 800ms, 50ms at full load±2.0% | |||||
HOLD UP TIME | 20ms | |||||
INPUT | VOLTAGE RANGE | 110/220VAC Selected | ||||
AC CURRENT(Typ.) | 0.35A/ 226VAC 0.18A/ 240VAC | |||||
CONNECTION TERMINAL | MARK: FG,AC-L, AC-N, | |||||
INPUT FREQUENCY | 47-63Hz | |||||
EFFICIENCY(Typ.) | 78% | |||||
INRUSH CURRENT(Typ.) | COLD START 30A/230VAC 0.5Ma/230VAC | |||||
LEAKAGE CURRENT | <3.5mA/240VAC | |||||
PROTECTION | OVER LOAD | 115%~135% of rated power; Pulsing hicuup shut down,auto recovery | ||||
OVER VOLTAGE | Rated output voltage of 105%~150% start overvoltage protecion | |||||
Protection: burst mode,load of abnormal conditions removed the automatic recovery | ||||||
SHORT CIRCUIT | voltage off and reset input for recovers | |||||
ENVIRONMENT | WORKING TEMP. | -0°C ~ +45°C (Refer to output load derating curve) | ||||
WORKING HUMIDITY | 20 ~ 90% RH non-condensing | |||||
STORAGE TEMP.,HUMIDITY | -20°C ~ +85°C 10~95% RH | |||||
TEMP. COEFFICIENT | ±0.05%/°C | |||||
COOLING METHOD | BY FREE AIR CONVECTION | |||||
SAFTY & EMC | SAFTY STANDARDS | CE EN60950-1 Approved | ||||
WITHSTAND VOLTAGE | I/P-O/P:1.5KVAC, I/P-FG:1.5KVAC, O/P-FG:0.5KVAC | |||||
ISOLATION RESISTANCE | I/P-O/P, I/P-FG,O/P-FG: 100M Ohms/ 500VDC | |||||
EMI CONDUCTION | Compliance to EN55022 | |||||
HARMONIC CURRENT | Compliance to EN61000-3-2,-3 | |||||
EMS IMMUNITY | Compliance to EN55024 | |||||
OTHERS | DIMENSION | L88*W90*H38MM | ||||
WEIGHT | 0.23Kg,52PCS/Carton | |||||
SHELL MATERIAL | Chassis:1.0mm thickness aluminium;Cover:0.7mm thickness iron(silver plating |
AC input voltage range…………………………………………… 176-264VAC
Input frequency…………………………………………………………47-63Hz
Line regulation(full load) ……………………………………………… ±0.5%
Output over load protection……………105%-150% hiccup mode, auto-recovery
Rise, hold up time……………………………………100mS 10mS at full load
Withstand voltage…………I/P-O/P, I/P-FG: 1.5KVAC, O/P-FG: 0.5KVAC,1 min
Working temperature…………-20℃~+60℃(refer to temperature derating curve)
Storage temperature…… -40℃~+85℃@100% 20%~95%RH (non condensing)
Safety standards……………… UL1310,class 2,TUV,EN60950-1,EN61347-2-13
EMC standards………………………………………………… FCC PART15J
Cooling method………………………………………Free air cooling convection
Model No. | DC output | Tol. | R&N | Effi. |
CV-60WG-5(CLF-05060) | 5V,0~8A | ±5% | 100mV | 72% |
CV-60WG-12(CLF-12060) | 12V,0~5A | ±3% | 120mV | 80% |
CV-60WG-15(CLF-15060) | 15V,0~4A | ±2% | 150mV | 80% |
CV-60WG-24(CLF-24060) | 24V,0~2.5A | ±2% | 240mV | 82% |
CV-60WG-36(CLF-36060) | 36V,0~1.67A | ±1% | 360mV | 82% |
CV-60WG-48(CLF-48060) | 48V,0~1.25A | ±1% | 480mV | 84% |