  HIGH PRECISE BANTE900 Precision pH/mV/ORP/Temp./Ion Meter

 HIGH PRECISE BANTE900 Precision pH/mV/ORP/Temp./Ion Meter

 

 

Bante900 Benchtop Multiparameter Water Quality Meter

High accuracy multiparameter water quality meter includes 15 optional parameters, the meter is suitable for measuring the pH, ORP, Ion concentration, Conductivity, TDS, Salinity, Resistivity and Dissolved Oxygen of the liquids.

pH Mode:
• High accuracy benchtop multiparameter water quality meter is equipped with a large backlit
  LCD display.
• 1 to 5 points push-button calibration with auto-buffer recognition.
• Selectable pH buffer standards (USA/NIST/DIN) or using the custom calibration solutions.
• Automatic electrode slope display helps user decide whether to replace sensor.

ORP Mode:
• Single point offset calibration allows adjusting the displayed value to a known standard.
• Relative and absolute millivolt measurement modes provide accurate ORP readings.

Ion Mode:
• 2 to 5 points calibration including the eight concentration calibration points can be selected.
• Automatically recognize ion selective electrodes, does not need to specify type of ion.
• Direct ion concentration readout simplifies the elaborate measurement process.
• Selectable multiple concentration units including the ppm, mg/L and mol/L.

Conductivity/TDS/Salinity/Resistivity Mode:
• 1 to 5 points push-button calibration with automatic calibration solution recognition.
• Selectable cell constants (0.1/1/10), normalization temperatures (20/25°C), TDS conversion
  factors, seawater and practical salinity measurement modes.

Dissolved Oxygen Mode:
• 1 or 2 points calibration using air-saturated water and zero oxygen solution.
• Manual salinity and barometric pressure compensation improve the measurement accuracy. 

Other Features:
• Automatic Temperature Compensation provides accurate reading over the entire range.
• Calibration Due Reminder prompts user to calibrate the meter regularly.
• Stability indicator automatically shows current measurement status.
• Auto-Hold function freezes stable measured value for easy viewing and recording.
• Manual temperature calibration corrects temperature deviation.
• Selectable temperature unit (°C or °F) meets different application requirements.
• Automatic electrode diagnosis shows zero point offset and slope of the electrode.
• Help message as a operational guide that helps you quickly begin using the meter.
• System menu allows setting the 15 parameters, including the calibration points, resolutions,
  stability conditions, measurement units, etc.
• Reset feature automatically resumes all parameters back to factory default options.
• Expanded memory stores and recalls up to 500 readings.
• Built-in real-time clock stamps stored data to meet GLP standard.
• Stored data can be transferred into computer by USB communication interface.

SpecificationsOrder InformationOptional AccessoriesPackaging

   Model

 

Bante900

   pH

   Range

 

-2.000~20.000pH

   Accuracy

 

±0.002pH

   Resolution

 

0.1, 0.01, 0.001pH

   Calibration Points

 

1 to 5 points, USA, NIST, DIN Standards

   Temperature Compensation

 

0~100°C, 32~212°F, Manual or Automatic

   mV

   Range

 

-1999.9~1999.9mV

   Accuracy

 

±0.2mV

   Resolution

 

0.1, 1mV

   Calibration Points

 

1 point (Only for Relative mV mode)

   Calibration Range

 

±200mV

   Ion

   Range

 

0.001~19999ppm, mg/L, mol/L (Depending on range of ISE)

   Accuracy

 

±0.5% F.S (Monovalent), ±1% F.S (Divalent)

   Resolution

 

0.001, 0.01, 0.1, 1

   Calibration Points

 

2 to 5 points

   Calibration Solutions

 

0.001, 0.01, 0.1, 1, 10, 100, 1000, 10000ppm, mol/L, mg/L

   Conductivity

   Range

 

0~20.00, 200.0, 2000µS/cm, 20.00, 200.0mS/cm

   Accuracy

 

±0.5% F.S

   Calibration Points

 

1 to 5 points

   Calibration Solutions

 

10µS/cm, 84µS/cm,1413µS/cm,12.88mS/cm,111.8mS/cm

   Temperature Compensation

 

0~100°C, 32~212°F, Manual or Automatic

   Temperature Coefficient

 

0.0~10.0%/°C

   Compensation Modes

 

Linear or Pure Water

   Cell Constant

 

K=0.1, 1, 10

   Normalization Temperature

 

20 or 25°C

   TDS

   Range

 

0~10ppt (Max. 20ppt, depending on factor setting)

   Accuracy

 

±1% F.S

   TDS Factor

 

0.1~1.0 (Default 0.5)

   Salinity

   Range

 

0~10ppt (Max. 80ppt)

   Accuracy

 

±1% F.S

   Measurement Modes

 

Seawater or Practical Salinity

   Resistivity

   Range

 

0~100MΩ

   Accuracy

 

±1% F.S

   Resolution

 

0.01, 0.1, 1

   Dissolved Oxygen

   Range

 

0.00~20.00mg/L (or ppm)

   Accuracy

 

±0.2mg/L

   Resolution

 

0.01mg/L

   Calibration Points

 

1 or 2 points

   Temperature Compensation

 

0~50°C, 32~122°F

   Pressure Correction

 

60.0~112.5kPa, 450~850mmHg

   Salinity Correction

 

0~50g/L

   % Saturation of Oxygen

   Range

 

0.0~200.0%

   Accuracy

 

±2.0%

   Resolution

 

0.1%

   Temperature

   Range

 

0~105°C, 32~221°F

   Accuracy

 

±0.5°C, ±0.9°F

   Resolution

 

0.1°C

   Calibration Points

 

1 point

   Calibration Range

 

Measured value ±10°C

   Others

   Hold Function

 

Manual or Automatic

   Stability Conditions

 

Low or High

   Calibration Due

 

0 to 31 days

   Power Off

 

Manual or Automatic (10, 20, 30 minutes)

   Reset Function

 

Yes

   Memory

 

Stores up to 500 data sets

   Output

 

USB Communication Interface

   Connector

 

BNC, 6-pin Mini Plug

   Display

 

LCD

   Power Requirements

 

DC5V, using AC adapters, 220VAC/50Hz

   Dimensions

 

210(L)×188(W)×60(H)mm

   Weight

 

1.5kg

 

Packaging & Shipping

HIGH PRECISE BANTE900 Precision pH/mV/ORP/Temp./Ion Meter 

 

Our service

As one part of Chincan Sales Group, each factory has technical support staffs available offering repair and maintenance of the products exported by Chincan. We promise that all of our products will be easily accessible to technical support and manufacturer's representatives who are always ready and able to assist when needed.

 

Company information

HIGH PRECISE BANTE900 Precision pH/mV/ORP/Temp./Ion Meter 

 

FAQ

Q: What after-sales service can be provided by CHINCAN ?

A: The after-sales service of CHINCAN is divided into two parts: technical support and maintenance.

 

Q: What about the technical support and maintenence?

A: Sometimes users will get some problems when they operate the instruments which are unfamiliar or first time use, users 

   can send us emails or call us about detailed information. We will provide users solution or operation video.For so many years

    experience, our instruments works well during warranty period. If there any parts are broken during warranty period, we would 

    like to provide spare parts for free.

 

Q: How to solve the disputes between CHINCAN and customers during the after-sales maintenance? 

A: We will be customer oriented,and make concessions in some principles , we will properly handle the disputes to maximize

    customer's satisfaction. 

 

Warranty

Normally all CHINCAN products are supplied with a warranty of 12 Months from the date of shipment. This warranty is entirely dependent on the following conditions

 

1.The following circumstance don't belong to the warranty policy which is Man-made damages caused by improper operations.

 

2.The instruments must be operated in accordance with our operating guidelines; serviced and maintained on a regular basis 

    in accordance with the terms specified in the relevant user manual.

3. Only approved spare parts should be used in the instruments which bought from CHINCAN and these should be changed on

    a regular basis as specified in the relevant user manual. Details of the approved spare parts and accessories for each 

    instrument are shown in the user manual or alternatively this information can be obtained from CHINCAN.

Contact Supplier

Mr. Tom Fang Chat Now
Telephone
0086-571-87977725
Address
No.56 Liuhe Rd. Hangzhou,Zhejiang

You May Like

New Products

Recommended Products

View More View Less

Find Similar Products By Category

Measurement & Analysis Instruments > Analyzers > PH Meters
Categories
Hi~