Prima series water purification system, water purifier (Tap water inlet)with the best price Supplier's Choice
USD $2,000 - $5,000 /Set
Min.Order:1 Set
Hangzhou Chincan Trading Co., Ltd.
Edi-series water purification system/ water purifier with the best price
Smart-D ultrapure water system/water purification system (Distilled water inlet)
Smart-Q deionized water system/water purification system (Tap water inlet)
Smart-S ultrapure water system /water purification system(Tap water inlet)
Smart-RO reverse osmosis water system /water filter system(Tap water inlet)
Prima series water purification system, water purifier with the best price
Prima series uses the largest size of acrylic crystal touch screen panel in the field of lab water purification system. It has the following functions, 3 way on-line water quality sensor, flow rate record, 5 stage cartridge alarm, leakage alarm, women voice alarm, perpetual calendar clock and so on. Moreover, it has one built-in 12 liters tank and one-pack cartridges.
Excellent choice of high performance price ratio.
Prima has 2 sub-series and its output is 15 or 30 liters/hour.
Prima-Q series produces deionized water and RO water.
Prima-S series produces ultrapure water and RO water.
The largest size (280x118mm) of acrylic crystal touch screen panel in the field of lab water purification system.
Automatic microcomputer controlling system, multi-menu operating.
3 way on-line sensor, detect the quality of feed water, RO water, deionized water or ultrapure water respectively.
Flow rate record function, and cartridges management function on the basis of flow rate record and service time.
5 stage cartridges alarm function, the cartridges’ life-span can be set, the time used and left can be displayed, replacing auto-reminding, avoiding the decline of water quality.
Standard women voice alarm function.
Multiple alarm functions: such as no water, full water, leakage, disqualification of feed water, RO water and ultrapure water, cartridges’ life-span ends.
Perpetual calendar clock, easy to set the life-span of cartridges.
Self-flushing of the reverse osmosis membrane, flushing time and time interval setting, to extend the life of RO membrane.
Built-in 12 liters pressure tank, save lab space and easy to maintain.
Different external tanks (optional) to meet every need and assure ample water-supply.
Human engineering design, molding process, high-strength, streamline plastic shell.
Pretreatment cartridges, RO module, ultrapure cartridges, all designed to modularization independently. Easy to maintenance and replacement.
Pipeline and fast-plug adaptor with NSF authorization, assure high quality ultrapure water.
KDF pretreating cartridge, replace the ordinary active carbon, prolong the life-span to 12 months, reduce the running cost.
DOW’s RO membrane, ensure stable operation and high desalinization rate.
4 in 1 ultrapure cartridges (also can be divided to 4 independent cartridge), with DOW’s nuclear-grade polishing resin, ensure ultrapure water’s quality up to 18.2 MΩ.cm, with the lowest TOC dissolution.
Double wavelength (185&254nm) ultraviolet lamp module, restrain bacteria’s increase and reduce TOC.
MWCO 5000D ultrafiltration module, effectively eliminate endotoxin precise cell cultivating and IVF.
(0.45+0.1)µm double layer PES terminal disinfection filter, assure the quality absolutely axenic.
Prima-Q deionized water system (Tap water inlet)
Prima-Q series is excellent choice of high performance price ratio for general analysis pure water. It has 2 kinds of output, 15 or 30 liters/hour. And the resistivity, reaching to 16-18.2MΩ.cm, is above of the grade I standard of GB6682-2008. It also meets the most requirements of chemical and biological experiments’ pure water.
Prima-S ultrapure water system (Tap water inlet)
Prima-S series is excellent choice of high performance price ratio for high grade experiments ultrapure water. It has 2 kinds of output, 15 or 30 liters/hour. And the resistivity, absolutely reaching to 18.2MΩ.cm, completely meets the highest grade I standard of GB6682-2008, ASTM, CAP, CLSI, EP and USP.
Model | Prima-Q15 | Prima-Q15UT | Prima-Q30 | Prima-Q30UT |
Feed water requirements* | Tap water: TDS<200 ppm, 5-45C, 1.0-4.0Kgf/cm2 (Extra pretreatment filter is recommended, if TDS>200ppm) | |||
Flow procedure** | PF+KDF+AC+RO+AC+DI | PF+KDF+AC+RO+AC+DI+UV+TF | PF+KDF+AC+RO+AC+DI | PF+KDF+AC+RO+AC+DI+UV+TF |
Deionized water quality: | ||||
Resistivity | >16-18.2MΩ.cm | |||
Heavy metal ion | <0.1ppb | |||
Bacteria | N/A | <0.1cfu/ml | N/A | <0.1cfu/ml |
Particle(>0.2μm) | N/A | <1/ml | N/A | <1/ml |
RO water quality: | ||||
Ion rejection rate | 96%-99% (New RO membrane) | |||
Organic rejection rate | >99%, when MW>200 Dalton | |||
Particles and bacteria rejection rate | >99% | |||
Pretreating water quality | ||||
| Just for glassware washing | |||
Output(25℃)*** | 15 liters/hour | 30 liters/hour | ||
Flow rate | 2.0 liters/minute(with pressure tank) | |||
Pure water outlet | 3:pretreating water, RO water, deionized water | |||
Dimension/Weight | Length×Width×Height:500×360×540mm/ Weight: about 22Kg | |||
Electric requirements | AC110-220V, 50/60Hz, 72W | |||
Standard configuration | Main body (Including 1 set of cartridges)+built-in12 liters tank+accessory bag |
Model | Basic | Eliminating endotoxin | Low TOC | Synthesizing |
Prima-S15 | Prima-S15UF | Prima-S15UV | Prima-S15UVF | |
Prima-S30 | Prima-S30UF | Prima-S30UV | Prima-S30UVF | |
Feed water requirements* | Tap water: TDS<200 ppm, 5-45C, 1.0-4.0Kgf/cm2 (Extra pretreatment filter is recommended, if TDS>200ppm) | |||
Flow procedure** | PF+KDF+AC+RO+DI+TF | PF+KDF+AC+RO+DI+UF+TF | PF+KDF+AC+RO+DI+UV+DI+TF | PF+KDF+AC+RO+DI+UV+DI+UF+TF |
Ultrapure water quality: | ||||
Resistivity(25℃) | 18.2MΩ.cm | |||
Heavy metal ion | <0.1ppb | |||
TOC*** | <10ppb | <10ppb | <3ppb | <3ppb |
Bacteria | <0.1cfu/ml | |||
Endotoxin | N/A | <0.001Eu/ml | N/A | <0.001Eu/ml |
Particle(>0.2μm) | <1/ml | |||
RNases | N/A | <0.01ng/ml | N/A | <0.01ng/ml |
DNases | N/A | <4pg/μl | N/A | <4pg/μl |
Deionized water quality: | ||||
Resistivity | >5MΩ.cm | |||
RO water quality: | ||||
Ion rejection rate | 96%-99% (New RO membrane) | |||
Organic rejection rate | >99%, when MW>200 Dalton | |||
Particles and bacteria rejection rate | >99% | |||
Output(25℃)**** | S15:15 liters/hour, S30:30 liters/hour, | |||
Flow rate | 2.0 liters/minute(with pressure tank) | |||
Pure water outlet | 3:RO water, deionized water, ultrapure water | |||
Dimension/Weight | Length×Width×Height:500×360×540mm/ Weight: about 25Kg | |||
Electric requirements | AC110-220V, 50/60Hz, 72W | |||
Standard configuration | Main body (Including 1 set of cartridges)+built-in12 liters tank+accessory bag |
* The feed water quality will influence the pure water’s quality and cartridges’ life-span.
** PF:polypropylene spun fiber, KDF:kinetic degradation fluxion, AC:active carbon, RO:reverse osmosis, DI:ion exchange, UV:ultraviolet, UF:ultrafiltration, TF:terminal microfiltration.
*** Value of number will be influenced by temperature and feed water quality.
**** All the specifications are tested under the situation:feed water’s TDS=200ppm, 25C, 50psi and 15% recovery rate.
As one part of Chincan Sales Group, each factory has technical support staffs available offering repair and maintenance of the products exported by Chincan. We promise that all of our products will be easily accessible to technical support and manufacturer's representatives who are always ready and able to assist when needed.
Q: What after-sales service can be provided by CHINCAN ?
A: The after-sales service of CHINCAN is divided into two parts: technical support and maintenance.
Q: What about the technical support and maintenence?
A: Sometimes users will get some problems when they operate the instruments which are unfamiliar or first time use, users
can send us emails or call us about detailed information. We will provide users solution or operation video.For so many years’
experience, our instruments works well during warranty period. If there any parts are broken during warranty period, we would
like to provide spare parts for free.
Q: How to solve the disputes between CHINCAN and customers during the after-sales maintenance?
A: We will be customer oriented,and make concessions in some principles , we will properly handle the disputes to maximize
customer's satisfaction.
Normally all CHINCAN products are supplied with a warranty of 12 Months from the date of shipment. This warranty is entirely dependent on the following conditions:
1.The following circumstance don't belong to the warranty policy which is Man-made damages caused by improper operations.
2.The instruments must be operated in accordance with our operating guidelines; serviced and maintained on a regular basis
in accordance with the terms specified in the relevant user manual.
3. Only approved spare parts should be used in the instruments which bought from CHINCAN and these should be changed on
a regular basis as specified in the relevant user manual. Details of the approved spare parts and accessories for each
instrument are shown in the user manual or alternatively this information can be obtained from CHINCAN.