GC102AF/GC112A High Accuracy Lab Gas Chromatograph Analyzer with FID TCD Detector & Air Compressor
USD $1,000 - $2,000 /Unit
Min.Order:1 Unit
Hangzhou Chincan Trading Co., Ltd.
GC102AF/GC112A High Accuracy Lab Gas Chromatograph Analyzer with FID TCD Detector & Air Compressor
GC102AF Main Picture
As a new generation instrument, GC102AF Gas Chromatograph applies the computer reverse control technology and can conduct remote detection and fault diagnosis, equipped with a flame ionization detector (FID).
Features:
1.PC control, user-friendly interface, and easy to operate.
2.Temperature control is of high accuracy (better than ±0.1℃). Heating speed is fast and overshoot temperature is small.
3.Self-diagnosis, power protection, oven over-temperature protection, and automatic ignition.
4.It can accurately display the temperature control settings, actual value, and FID amplifier sensitivity.
5.The single gas system and precise scale pneumatic control valve contribute to excellent reproducibility and stability and can perform analysis of packed column or capillary with wide diameter of 0.53mm.
6.Packed column: on-column injection, instantaneous vaporization injection, gas injection.
7.Open computer system and NJ2000 chromatography workstation can work together to process data.
8.Large capacity oven (300mm×280mm×270mm) facilitates the installation of packed column and capillary.
9.Built-in heating wire structure.
Technical specifications:
Temperature Control:
1. Temperature area: column oven, sampler, detector
2. Temperature range: 15℃ ~399℃ above room temperature (increment: 1℃)
3. Temperature accuracy: better than ±0.1℃ (measured at 200℃)
Flame Ionization Detector (FID):
1. Detection limit: Dt≤1×10-10g/s (octane and hexadecane)
2. Baseline drift: ≤2×10-12A/h
3. Linear range: ≥106
4. Max. limit temperature: 400℃
Others:
1. Voltage: 220V~±22V 50Hz±0.5Hz
2. Power: ≤1500W
3. Dimensions: 575mm(L)×480(W)×490mm(H)
4. Weight: 50kg
Optional:
NJ2000 chromatography workstation
GC112A Main Picture
Features:
1.High accuracy of temperature control (optimum: ± 0.05℃), high reliability and anti-interference.
2.Control and operating parameters (including for detectors) set up by the keyboard. Self-diagnosis system, power-fail protection, file storage and call, limited temperature setting. Accurate display of setting and actual value of temperature control of each path, bridge current of TCD, sensitivity of FID, retention and analysis time.
3.Four paths of independent control sections: column oven, sample injector, detector and thermal conductive pond.
4.5-ramp programmed temperature rising control. Auto-drop of temperature of column oven (auto-opening the door behind the oven) to a fast cooling.
5.Dual FID provided with options of GC112 A-TCD, gas sampling valve, transformation oven, absorber and pyrolysis absorber available for selection. Two detectors can be installed at the same time with high sensitivity. Short time to be stabilized and easy to clean and install nozzle.
6.Packed column and capillary column (0.53 large diameter or small diameter) can be installed easily including a complete set of split sampling connector and tailing connector to be installed free of charge.
7.Analysis can be conducted in packed or capillary column with multiple sampling methods.
8.Packed column: on-column sampling, instantaneous vaporized sampling and gas sampling.
9.Capillary column: split sampling and 0.53mm large diameter capillary direct sampling.
10.Construction of dual gas path, dual sample injector and dual packed column system can effectively avoid baseline undulation and drift in real time and facilitate programmed temperature rising analysis. Accurate and scaled type gas path control valves will provide a high repeatability and stability.
11.Advanced functions: auto ON/OFF temperature control system, permanent data storage, file storage and call and over-temperature protection.
12.Large volume column (300x280x270mm) can hold capillary column and dual packed column. Built-in heating filament structure is in favor of quartz capillary analysis.
13.A complete set of accessories including purifier, pressure-reducing valve, gas path tube, wrench and tools, injection needle and connectors of all kinds are provided free of charge and are ready to connect with supply-air system prepared by users.
Specifications:
Temperature control
Control range | above room temperature 7℃- 400℃. (increment of 1℃) |
Control objects | column oven, detector, thermal conductive pond and sample injector |
Programmed temperature rising | 5 ramps |
Rate of programmed temperature rising | 0.1℃- 40℃/min (increment of 0.1℃) |
Thermostatic time | 0-655 min (increment of 1 min) |
FID
Sensitivity (minimum testability) | D≤5×10-11 g/s (sample: C16) |
Optimum testing result | D≤1×10-11 g/s |
Noise | ≤5×10-14 A |
Drift | ≤6×10-13 A/h |
Linear range | ≥106 |
TCD
Sensitivity | ≥2000mV.ml/mg |
Noise | ≥20μV |
Drift | ≤30μV |
Linear range | ≥104 |
Optional Accessories:
TCD
FPD
NPD
N2000 Software with I/O port
OVERALL DIMENSION & WEIGHT
Shipping package dimension: 990x630x690mm
Net Weight: 50kg
Gross Weight: 75kg
Hot-selling Products:
This year Shipping shows:
As one part of Chincan Sales Group, each factory has technical support staffs available offering repair and maintenance of the products exported by Chincan. We promise that all of our products will be easily accessible to technical support and manufacturer's representatives who are always ready and able to assist when needed.
Established in 2004, Hangzhou Chincan Trading Co., Ltd. is a foreign trading company authorized by Chinese State Department of Foreign Economy & Trade and General Administration of Chinese Customs, which located in Hangzhou city, Zhejiang province, China.
We are a specialist company committed to exporting laboratory instruments, educational apparatus, medical & hospital equipments. With its superior performance, Chincan instruments are sold well throughout the Americas, Asia Pacific, the Middle East, Africa and Europe. With our excellent service, Chincan Trading has won a good reputation from the market.
Cooperative factories which qualified by Chincan come from many provinces and cities across China. All of them need to be ISO certified, Some products have CE.
Our customers spread all over the world, most products are very popular in Asia Pacific, Africa, Europe and South America, such as microscopes, autoclaves, shakers, incubators, baths, pH meters, spectrophotometers, pure water systems, balances, pipettes, centrifuges, viscometers, hardness testers, biological safety cabinets, etc. We are doing our best to meet various needs of clients from different countries.
Q: What after-sales service can be provided by CHINCAN ?
A: The after-sales service of CHINCAN is divided into two parts: technical support and maintenance.
Q: What about the technical support and maintenence?
A: Sometimes users will get some problems when they operate the instruments which are unfamiliar or first time use, users can send us emails or call us about detailed information. We will provide users solution or operation video.
For so many years’ experience, our instruments works well during warranty period. If there any parts are broken during warranty period, we would like to provide spare parts for free.
Q: How to solve the disputes between CHINCAN and customers during the after-sales maintenance?
A: We will be customer-oriented,and make concessions in some principles , we will properly handle the disputes to maximize customer's satisfaction.
Sophia Zhang(Ms.)
Hangzhou CHINCAN Trading Co.,Ltd.
Add: Rm.502 3A Zhongxun Building, NO.56 Liuhe Rd. Hangzhou Zhejiang 310023 China.
Tel:0086-571-87977725/7729
Fax:0086-571-87977703
Email: sophia @cktrade.com.cn
Web: