BioLum-III Portable ATP hygiene monitoring system (ATP meter)
USD $1,000 - $3,000 /Set
Min.Order:1 Set
Hangzhou Chincan Trading Co., Ltd.
BioLum-III Portable ATP hygiene monitoring system ( ATP Meter)
Summary:
Biolum III Portable ATP Hygiene Monitoring System, a powerful tool for implementing and managing your hygiene monitoring program. Taking advantages of the progressive QuickSwarb surface test, the hygiene level of the tested surface will be evaluated in seconds, and the results can be visualized on screen. Featuring the state-of-art technology, the BioLumIII is a user-friendly, flexible, and accurate quality monitoring system. It has all the features to maximize its value to your business.
Specifications:
ITEMS | PARAMETER |
Biolum-III | |
Dimensions | 189*70*36 mm |
Weight | ≤300g |
Detection limit | 1*10-16 moles ATP |
Detection Range | 0-999999RLUs |
Detection Deviation | ±5%or ±5RULs |
Self-calibration at startup | 30s |
Real-time detection time | 10s per test |
Programmable Test Locations | 255 programmable test points per test plan |
Storage Capacity | 10000 results |
Communication interface | USB, Bluetooth |
Reproducibility | CV 8%-20% |
Correlation Coefficient | R2 ≥0.99 |
Power Supply | Rechargeable battery |
Running Time | continuously work for >8 hrs, standby for >600hrs |
Temperatures allowed during operation | 5-40℃ |
Relative humidity allowed during operation | 20-80% |
QuickSwab | |
Swab strotage | -10- -20℃ 12monthes 2-8℃ 3 monthes |
Swab compatible | Biolum-II, Biolum-III Hygiena SystemSURE Plus, EnSURE, Others |
Method Comparison
Compare with the traditional cell culture method, ATP hygiene monitoring system is the method that combines quantitative data collection with scientific measurement and still delivers speed result.
Compared Items | ATP Detection based on BioLum-III | Conventional Bacteria Culture/Plating |
Microorganism | All Bacteria, Fungi, Algae. | Only the specific bacteria that grow on the culture media (Normally the LB agar culture can only detect aerobic bacteria). |
Aerobic bacteria | √ | √ |
Autotrophic heterotrophic bacteria | √ | × |
Acetobacter | √ | × |
Nitrite bacteria | √ | × |
Mycete | √ | √ |
Algae | √ | × |
Detection Time | 10 sec | 1-5 days |
Operation | simple, less steps, only one reagents is needed | The conditions that medium and detection needed are required, complicated operation, a variety of human factors may affect the result. |
Result | rapid, pre-alert and traceable | processing lags, the result can be reserved for a long time and for further detection. |
Combined with two methods, utilize ATP detection method for contamination detection and conventional culture method to detect the species of bacteria and the contamination sources. |
Food Processors
1. Cleaning control the process of production and processing
2. Evaluating the disinfection of packaging
3. Testing the microbes of finished products and material
4. Monitoring the hygiene of processing environment
Food Service
1. Cleanliness control of the kitchen, dishes, operating carton and tools
2. Evaluating disinfection of dishes
3. Disinfection control of the airline catering dishes
4. Hygiene supervision for quality control department
Health Care
1. Objects superficial inspection of the hospital major department
2. Hand cleaning check of the medical staffs
3. Medical equipment cleanliness and disinfection inspection
4. Cleanliness testing of the hospital environment
Environment protection
1. Evaluating biologicalpollutionof the water and wastewater sample
2. Detecting the contaminating microorganisms of soil, activatedsludgesamples and so on.
Other Industries
1. Daily health products manufacture
2. Qualitysupervisiondepartment
3. Hospitality industry hygiene management
4. The port supervision etc
Q: What after-sales service can be provided by CHINCAN ?
A: The after-sales service of CHINCAN is divided into two parts: technical support and maintenance.
Q: What about the technical support and maintenence?
A: Sometimes users will get some problems when they operate the instruments which are unfamiliar or first time use, users can send us emails or call us about detailed information.
We will provide users solution or operation video.
For so many years’ experience, our instruments works well during warranty period. If there any parts are broken during warranty period, we would like to provide spare parts for free.
Q: How to solve the disputes between CHINCAN and customers during the after-sales maintenance?
A: We will be customer-oriented,and make concessions in some principles , we will properly handle the disputes to maximize customer's satisfaction.
Established in 2004, Hangzhou Chincan Trading Co., Ltd. is a foreign trading company authorized by Chinese State Department of Foreign Economy & Trade and General Administration of Chinese Customs, which located in Hangzhou city, Zhejiang province, China.
We are a specialist company committed to exporting laboratory instruments, educational apparatus, medical & hospital equipments. With its superior performance, Chincan instruments are sold well throughout the Americas, Asia Pacific, the Middle East, Africa and Europe. With our excellent service, Chincan Trading has won a good reputation from the market.
Cooperative factories which qualified by Chincan come from many provinces and cities across China. All of them need to be ISO certified, Some products have CE.
Our Website:
1. As one part of Chincan Sales Group, each factory has technical support staffs available offering repair and maintenance of the products exported by Chincan.
2. We promise that all of our products will be easily accessible to technical support and manufacturer's representatives who are always ready and able to assist when needed.