Hot sales quality,12.1inch TFT fetal monitor portable size for prenatal maternal monitor CE marked
Negotiable /Unit
Min.Order:1 Unit
Shenzhen Jumper Medical Equipment Co., Ltd.
Jumper fetal monitor JPD-300P 12.1inch CE marked
Technical Date L8P fetal/maternal monitor Fetal Heart Rate: Transducer: Multi-crystals, pulsed doppler , high sensitively Strength: <5mW/cm2 Working frequency: 1.0MHz Signal processing: special DSP system and modern recognization. Measurement range: 50~210 bpm Alarm Range: High limit: 160,170,180,190 bpm Low limit: 90,100,110,120 bpm Maximum audio output power : 1.5 Watt Toco: Measurement range: 0~100 units Maternal SpO2 measure: Measure scope : 70%~99%. Measure accuracy: ±3% Pregnant HR Measure: Measure scope: 30bpm~240bpm Measure accuracy: ±2 bpm NIBP measure: a) NIBP-SYS (6.7~32.0Kpa)(50~240mmHg) b) NIBP-DIA (3.4~26.6Kpa)(25~200mmHg) c) NIBP-MEAN(2.0~24.0ka(15~180mmHg) NIBP Accuracy: ±1.1kPa(±8mmHg)or ±5% of the results, take the bigger one. Maximum Mean error : ±5mmHg Maximum Standard deviation 8mmHg Pulse Rate Accuracy: Maximum Mean error : ±2bpm Measure accuracy: ±2 bpm or ±5% of the results, take the bigger one. Measure mode: Manual ECG Heart Rate Measurement and Alarm Range: 15-300bpm Accuracy: ±1bpm Heart Rate Average: 8 beats Lead Selection: II Input: 5-lead ECG cable Sweep Speed: 25 mm/s Amplitude Selection: x1/4, x1/2, x1, x2, x4 Frequency Response: Monitoring: 0.5 to 35Hz (+0.4dB, 3.0dB) Defibrillation Protection: 5kV test Recovery Time Following Defibrillation: Less than 5 seconds Temperature: Measurement and Alarm Limit: 0-50°C Probe: Skin surface Unit: Celsius/Fahrenheit Accuracy: ±0.1°C(25°C ~45°C), ±0.2°C(0°C ~25°C or 45°C ~50°C) Resolution: 0.1°C Respiration Measurement Mode: Thoracic Impedance Respiration Rate: 0-150 bpm Waveform Display Speed: 25mm/s
Display: The LCD displays FHR, TOCO, FM , maternal parameters , time, date, volume and so on, It can store and play back the data. Power: a.c.100-240v, 50/60Hz or 16.8v Li-ION battery Power Consumption: < 20W Dimension: 350W×320D×85H(mm) Net weight:3.5kg Packing size:41.3×39-×24.5 (mm) Gross Weight:9Kg Environment Working environment: Temperature: +5°C ~ +40°C Humidity: < 85% Atmospheric pressure: 86kPa ~ 106kPa Transport and storage temperature: Temperature: -10°C ~ +55°C Humidity: < 93% Atmospheric pressure: 86kPa ~ 106kPa Transducer Acoustic Output: Under the requirements laid down in IEC 1157, 1992, the peak negative acoustic pressure does not exceed 1Mpa. The output beam intensity does not exceed 20mW/cm2 and the spatial-peak temporal-average intensity does not exceed 100mW/cm2 GEL: Viscous aqueous non-sensitizing , hypo-allergenic and non-irritating to skin. Indefinite shelf life, Bacteriostat (not sterile). |