Radiation cross-linking ETFE wires and cables
Negotiable /Kilometer
Min.Order:1 Kilometer
Xiangtan Shenzhou Special Cable Co., Ltd.
DESCRIPTION
Radiation cross-linking ETFE wires and cables
1.Rated a.c. voltage is up and including 600V;
2.The maximum continuous long-time operating temperature of tinned copper conductor is 150°c,
and those of silver-plated & nickel-plated copper conductor is 200°c.
3.The wires are used as the electric connection of electric equipment and instrument applies.
4.Types and description of wires and cables are given in table 1.
Table1
Type | Description |
FJF40Q-X | X-ETFE insulated electrical wires and cables(light weight) |
FJF40PQ-X | X-ETFE insulated sreened elecrical wires and cables(light weight) |
FJF40PHQ-X | X-ETFE insulated screened,shiled,electrial wires and cables(light weight) |
P11----tinned copper conductor knitting screened
p21----silver-plated copper conductor knitting screened
p31----nickel-plated copper conductor knitting screened
H03--- FEP shield
H10---ETFE shield
JH10---X-ETFE shield
5.Specification and construction diemension are given in table2.
Tabler2
No | Nominal area mm2 | AWG | Construction | Outer diameter(mm) | Max.weight(kg/km) | Max.d.c.resistance of conductor | ||
Tinned | Silver-plated | Nickel-plated | ||||||
1 | 0.06 | 30 | 7/0.10 | 0.60+-0.05 | 0.983 | 356 | 336 | 370 |
2 | 0.08 | 28 | 7/0.12 | 0.69+-0.05 | 1.36 | 225 | 209 | 223 |
3 | 0.15 | 26 | 19/0.10 | 0.81+-0.05 | 2.09 | 136 | 126 | 138 |
4 | 0.20 | 24 | 19/0.12 | 0.94+-0.05 | 2.98 | 86 | 79.7 | 85 |
5 | 0.30(0.35) | 22 | 19/0.16 | 1.09+-0.05 | 4.17 | 53.1 | 49.5 | 52.5 |
6 | 0.5(0.6) | 20 | 19/0.20 | 1.27+-0.05 | 6.40 | 32.4 | 30.2 | 32.1 |
7 | 1.0 | 18 | 19/0.26 | 1.52+-0.05 | 9.68 | 20.4 | 19.0 | 20 |
8 | 1.2 | 16 | 19/0.28 | 1.73+-0.05 | 12.4 | 15.8 | 14.8 | 15.6 |
9 | 2.0 | 14 | 19/0.37 | 2.16+-0.08 | 19.4 | 10 | 9.45 | 9.84 |
10 | 3.0 | 12 | 37/0.32 | 2.62+-0.08 | 29.3 | 6.63 | 6.23 | 6.50 |