TECHNIQUES SPECIFICATIONS | |
Physical specifications | |
Screen: | 10.4 '' LCD Display Screen |
Suitable | Adult & Child |
Mode: | pneumatically powered and electrically controlled system |
Working Mode: | Closed; Semi-Closed; Semi-Open |
Circuit | Breathing circuit integrated standards |
Flowmeters: | 5 Tubes Flowmeters: O2:0.1~10L/Min, N2O:0.1~10L/Min; Air: 0.1~10L / Min |
Trolley: | Fitted with 4 nos anti-static rubber castors; two of which are lockable for braking and easy maneuverability with foot operated brake provisions |
Drawer unit | TWO drawers totally extractable |
Technical Specifications: | |
Gas requirement: | Medical oxygen and nitrous oxide with a pressure ranging from O2: 0.32~0.6MPa ; NO2: 0.32 MPa to 0.6 MPa. |
safety valve | <12.5 kPa |
Respiratory Rate | 1~99bpm |
oxygen concentration in the mixed gas N2O/O2 | > 21% |
Oxygen Flush: | 25~75 L/min |
modes of ventilation | A/C, IPPV, SIPPV, IMV, SIMV, PCV, VCV, PEEP, MANUAL, SIGH |
PEEP: | 0 ~ 2.0 kPa |
Inspiratory trigger pressure | -1.0kPa ~ 2.0 kPa |
IMV frequency: | .. |
I/E Ratio: | 8:1 ~ 1:10, Has the inverse ratio ventilation |
Tidal Volume | 0 ~ 1500 ML |
Inspiratory Plateau: | 0~1s |
O2 Concentration: | 21%~100% |
Sigh: | one deep breath per 70 ~ 120 controlled respirations, the inspiration time is 1.5 times of the setting point |
Maximum safety pressure: | ≤ 12.5 kPa |
Pressure limit range: | 0 ~ 6.0 kPa |
Airway pressure alarm: Audible and visual and with yellow and red color indicating | Lower: 0.2kPa~5.0kPa; Upper: 0.3~6.0 kPa |
±0.2 kPa | |
Tidal volume alarm: Audible and visual and with yellow and red color indicating | upper alarm: 50 to 2000ml, lower alarm: 0~1800ml |
Oxygen concentration alarm: Audible and visual and with yellow and red color indicating | upper alarm: 21% ~100%; lower alarm:10%~80% |
Power Supply Alarm | Ac/dc power supply are after failing to send out alarm immediately Alarm Time: keep >120s |
The airway pressure continues to be higher than 15 hPa ±1 hPa for 15s±1s, then the machine will raise an audible alarm, the pressure will be displayed in red and the continuous high pressure red alarm wording is displayed on the screen of the anesthetic respirator. |
Mainly product:
Certificate
1.Why do you choose us?
We are a professional manufacturer with advanced production equipments and a complete set of
mature supply chain.
2.What advantages do you have?
Our production has the superior quality with competitive price. Regardless the quantity of your order,
We will provide the one-stop service for Pre-sale, sale and after-sale.
3. How to order ?
Please send me your purchase order ,or you can ask us to send you proforma invoice.
4. Training
We provide customers free training in our factory.The accommodation charge should be borne by customers.
5. Freight policy
1. Within Warranty:The customer should be borne freight & insurance charges when the equipment is shipped to FULLMEDI for service (this includes custom charges). FULLMEDI should be borne the freight & insurance charges from FULLMEDI to the customer.
2. After Warranty:The customer is responsible for any freight & insurance charges for returned product.