ac dc power adapter 10v 1.8a with CE RoHS UL FCC C-Tick SAA BEAB GS
USD $2.5 - $5 /Unit
Min.Order:500 Units
Shenzhen NiteRay Technology Co., Limited
PRODUCT HIGHLIGHT
1. Complete, inexpensive, self-contained
2. Regulated power source
3. Super power supply, fixed frequency control circuit guarantees Stable, long-lasting output required by any mobile Eectronics, such as mobile phones, PDA, Digital camera, CDMA Digital phones, Walkie- talkie, tester machine, HUB, Modem, Scanner, Printer and much more
4. Extra safe design, all with their respective
5. Safety approvals
6. Ultra low no-load /standby power consumption, meeting EC 2005 green power requirements
7. Light, sleek, and compact design
8. On-line LED power indicator
9. High efficiency circuitry that generates little heat B urn-in EMI filter
PROTECTION
Short circuit protection
Over voltage protection
Over current protection
Thermal shutdown capability
RELIABILITY
Burn-in: 100% full load, 40 ± 5° C, 4Hrs min
Leakage Current: 0.25mA max. At 254Vac
Withstanding Voltage: (between primary & secondary) 3000Vac 1 minute 10mA max
MTBF: Meet MIL-HDBK-217F over 50K hours, full load, 25 ° C
SAFETY APPROVALS:
UL60950 3 rd edition CAN/CSA C22.2 NO. 60950
EN60950: 2000
CE(Low Voltage Directive)
AS/NZS 60950: 2000
PSE IEC60950
GB4943-2001
EMISSIONS:
FCC Part15 class B
EN55022 class B
AS/NZS3548, AS/NZS4251.1 class B
VCCI class B
CNS13438 class B
GB9254-1998/GB17625.1-2003
CISPR22 class B
SAFETY APPROVALS
UL1310
EN60335
CE
IMMUNITY
EN55024/A1: 2001
Electrostatic discharge: 61000-4-2
Radiated electromagnetic fields: 61000-4-3
Fast transients(burst): 61000-4-4
Surge transients: 61000-4-5
Conducted disturbance: 61000-4-6
Voltage dips, interruptions&variations: 61000-4-11
INPUT CONDITION | DC OUTPUT VOLTAGE | DC OUTPUT CURRENT | OUTPUT VOLTAGE PRECISION | RIPPLE & NOISES | REGULATION | MAXIMAL OUTPUT POWER | ||
LINE | LOAD | |||||||
Input voltage: 90-264VacFrepuency: 47-63Hz Inputcurrent: 0.6A | 1 | 3.0-4.0V | 0.1-4.0A | 6% | 100 mV | ± 1% | ± 5% | 16W |
2 | 4.1-6.0V | 0.08-4.0A | 6% | 100 mV | ± 1% | ± 5% | 24W | |
3 | 6.1-6.9V | 0.07-4.1A | 6% | 100 mV | ± 1% | ± 5% | 25W | |
4 | 7.0-8.0V | 0.06-3.57A | 5% | 100 mV | ± 1% | ± 5% | 25W | |
5 | 8.1-9.0V | 0.055-3.09A | 5% | 100 mV | ± 1% | ± 5% | 25W | |
6 | 9.1-10.0V | 0.05-2.75A | 5% | 100 mV | ± 1% | ± 5% | 25W | |
7 | 11.1-11.9V | 0.04-2.25A | 5% | 100 mV | ± 1% | ± 5% | 25W | |
8 | 12.0-17.9V | 0.04-2.5A | 5% | 100 mV | ± 1% | ± 5% | 30W | |
9 | 18.2-22.0V | 0.035-1.67A | 5% | 100 mV | ± 1% | ± 5% | 30W | |
10 | 22.1-30.0V | 0.03-1.36A | 5% | 100 mV | ± 1% | ± 5% | 30W | |
11 | 30.5-31.0V | 0.025-0.98A | 5% | 150 mV | ± 1% | ± 5% | 30W | |
12 | 31.5-48.0V | 0.02-0.95A | 5% | 150 mV | ± 1% | ± 5% | 30W |
Description | Symbol | Min | Typ | Max | Units | Comment |
Input | ||||||
Voltage | V IN | 90 | 120/240 | 264 | V AC | 2 Wire no Protective Ground |
Frequency | F LINE | 47 | 50/60 | 63 | Hz | |
No-load Input Power(230VAC) | 0.5 | W | ||||
Efficiency | η | 75 | % | |||
Inrush Current(240Vac) | I | 40 | A | Cold 25 o C | ||
Environmental | ||||||
Operating Temperature | T | 0 | / | 40 | o C | Free convection, Sea level |
Non-operating temperature | T | -20 | / | 80 | o C | Free convection, Sea level |
Operating humidity | T | 10 | / | 90 | %RH | Non condensing |
Non-operating humidity | T | 10 | / | 90 | %RH | Non condensing |